DETERMINATION OF THE ABSOLUTE RADON CONCENTRATION IN AIR USING AN ELECTROSTATIC METHOD AND CR-39 DETECTOR

被引:5
|
作者
TETEREV, YG
TRETYAKOVA, SP
GOLOVCHENKO, AN
ILIC, R
SKVARC, J
机构
[1] UNIV LJUBLJANA,JOZEF STEFAN INST,LJUBLJANA 61111,SLOVENIA
[2] UNIV MARIBOR,FAC CIVIL ENGN,MARIBOR 62000,SLOVENIA
关键词
ALPHA PARTICLES; CR-39; ELECTROSTATIC FIELD; RADON;
D O I
10.1016/1350-4487(95)00210-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A method for the determination of absolute radon concentration by means of electrostatic collection of radon daughters at the surface of a track etch detector, followed by counting of single and paired (arising from genealogically correlated alpha-decays of the same nuclei) tracks is described.
引用
收藏
页码:645 / 646
页数:2
相关论文
共 50 条
  • [2] CR-39 RADON DETECTOR
    BING, S
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 451 - 454
  • [3] Measuring Radon Concentration Levels in Fertilizers using CR-39 Detector
    Aswood, Murtadha Sh
    Jaafar, Mohamad S.
    Bauk, Sabar
    MICRO/NANO SCIENCE AND ENGINEERING, 2014, 925 : 610 - +
  • [4] Measuring the radon concentration in housings connecting the radon spring bathroom by using the CR-39 detector
    Meng, Wenbin
    Qin, Changzhu
    Bi, Zhiying
    Feng, Yushui
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 1996, 30 (06): : 561 - 564
  • [5] Determination of the calibration factor for CR-39 based indoor radon detector
    Matiullah
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (01) : 369 - 373
  • [6] Determination of the calibration factor for CR-39 based indoor radon detector
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 298 : 369 - 373
  • [7] Developing a radon monitor with less influence of humidity based on electrostatic collection method and CR-39 detector
    Fan, Zhongkai
    Hu, Tao
    Xie, Ruomei
    Lin, Fen
    Mo, Yixiang
    Yuan, Shuai
    Liu, Shuaibin
    Yuan, Hongzhi
    Tan, Yanliang
    RADIATION MEASUREMENTS, 2022, 155
  • [8] Developing a radon monitor with less influence of humidity based on electrostatic collection method and CR-39 detector
    Fan, Zhongkai
    Hu, Tao
    Xie, Ruomei
    Lin, Fen
    Mo, Yixiang
    Yuan, Shuai
    Liu, Shuaibin
    Yuan, Hongzhi
    Tan, Yanliang
    Radiation Measurements, 2022, 155
  • [9] MEASUREMENT OF INDOOR RADON CONCENTRATION BY CR-39
    ZHAO, YH
    ZHAO, CD
    HAO, XH
    ZHOU, PD
    GUO, SL
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 523 - 526
  • [10] AN IMPROVED ELECTROSTATIC INTEGRATING RADON MONITOR WITH THE CR-39 AS ALPHA-PARTICLE DETECTOR
    Fan, D.
    Zhuo, W.
    Chen, B.
    Zhao, C.
    Yi, Y.
    Zhang, Y.
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 121 - 125