DETERMINATION OF THE ABSOLUTE RADON CONCENTRATION IN AIR USING AN ELECTROSTATIC METHOD AND CR-39 DETECTOR

被引:5
|
作者
TETEREV, YG
TRETYAKOVA, SP
GOLOVCHENKO, AN
ILIC, R
SKVARC, J
机构
[1] UNIV LJUBLJANA,JOZEF STEFAN INST,LJUBLJANA 61111,SLOVENIA
[2] UNIV MARIBOR,FAC CIVIL ENGN,MARIBOR 62000,SLOVENIA
关键词
ALPHA PARTICLES; CR-39; ELECTROSTATIC FIELD; RADON;
D O I
10.1016/1350-4487(95)00210-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A method for the determination of absolute radon concentration by means of electrostatic collection of radon daughters at the surface of a track etch detector, followed by counting of single and paired (arising from genealogically correlated alpha-decays of the same nuclei) tracks is described.
引用
收藏
页码:645 / 646
页数:2
相关论文
共 50 条
  • [41] A METHOD TO PROTECT CR-39 TRACK DETECTOR FROM SUNLIGHT
    AHMAD, N
    MIRZA, NM
    MIRZA, SM
    TUFAIL, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (07): : 1521 - 1522
  • [42] Determination of the Bulk Etch Rate of the Nuclear Track Detector CR-39 Using Le-D Method
    Al-Nia'emi, S. H. S.
    Kasim, Y. Y.
    JORDAN JOURNAL OF PHYSICS, 2013, 6 (01): : 17 - 25
  • [43] CALIBRATION OF A CR-39 PLASTIC TRACK DETECTOR FOR THE MEASUREMENT OF RADON AND ITS DAUGHTERS IN DWELLINGS
    KHAN, AJ
    VARSHNEY, AK
    PRASAD, R
    TYAGI, RK
    RAMACHANDRAN, TV
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1990, 17 (04): : 497 - 502
  • [44] Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements
    Nikezic, D.
    Yu, K. N.
    Stajic, J. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [45] Calibration technique for a CR-39 detector for soil and water radon exhalation rate measurements
    Almayahi, B. A.
    Tajuddin, A. A.
    Jaafar, M. S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 301 (01) : 133 - 140
  • [46] Intercomparison of radon CR-39 detector systems conducted in CLOR's calibration chamber
    Mamont-Ciesla, Kalina
    Stawarz, Olga
    Karpinska, Maria
    Kapala, Jacek
    Kozak, Krzysztof
    Grzadziel, Dominik
    Chalupnik, Stanislaw
    Chmielewska, Izabela
    Olszewski, Jerzy
    Przylibski, Tadeusz A.
    Zebrowski, Adam
    NUKLEONIKA, 2010, 55 (04) : 589 - 593
  • [47] Study on the influence of CR-39 detector size on radon progeny detection in indoor environments
    Pereira, L. A.
    Hadler, J. C.
    Lixandrao, A. L. F.
    Guedes, S.
    Takizawa, R. H.
    XXXVI BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2014, 1625 : 135 - 139
  • [48] Calibration technique for a CR-39 detector for soil and water radon exhalation rate measurements
    B. A. Almayahi
    A. A. Tajuddin
    M. S. Jaafar
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 301 : 133 - 140
  • [49] Investigation of radon concentration level and its progeny in different kinds of cancer by using Cr-39 NTD
    Othman, Sardar
    Salih, Najeba
    Hussein, Zakariya
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2023, 178 (3-4): : 456 - 484
  • [50] SOME BASIC STUDIES ON THE ABSOLUTE DETERMINATION OF RADON CONCENTRATION IN THE AIR BY A CELLULOSE NITRATE TRACK DETECTOR
    NAKAHARA, H
    KUDO, H
    AKIBA, F
    MURAKAMI, Y
    NUCLEAR INSTRUMENTS & METHODS, 1980, 171 (01): : 171 - 179