Voltammetric detection of As(III) with Porphyridium cruentum based modified carbon paste electrode biosensor

被引:25
|
作者
Zaib, M. [1 ,2 ]
Saeed, A. [1 ]
Hussain, I. [3 ]
Athar, M. M. [2 ]
Iqbal, M. [1 ,4 ]
机构
[1] Food & Biotechnol Res Ctr, Lahore 54600, Pakistan
[2] Univ Punjab, Inst Chem, Lahore 54590, Pakistan
[3] Lahore Univ Management Sci, Sch Sci & Engn, Dept Chem, Lahore 54792, Pakistan
[4] Ctr Appl Mol Biol, Lahore 53700, Pakistan
来源
关键词
As(III); Red alga; Modified carbon paste electrode; Voltammetry; FTIR; ANODIC-STRIPPING VOLTAMMETRY; DRINKING-WATER; ELECTROCHEMICAL DETECTION; MICROBIAL BIOSENSOR; ARSENIC(III); REMOVAL; BIOSORPTION; CADMIUM; RED; SPECIATION;
D O I
10.1016/j.bios.2014.06.055
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel biosensor based on carbon paste electrode modified with Porphyridium cruentum biomass was developed for the determination of As(III) in contaminated water. As(III) was first biosorbed-accumulated on the electrode surface at open circuit potential and then stripped off by applying anodic scan range of -0.8 to +0.8 V using differential pulse anodic stripping voltammetric technique. The best result was obtained at pH 6.0 with 0.1 M HNO3 solution as stripping medium, allowing biosorption-accumulation time of 8 min using 5% P. cruentum biomass in graphite-mineral oil paste. Linear range for As(III) detection with the modified electrode-biosensor was observed between 2.5 and 20 mu g L-1. The FTIR spectrum of P. cruentum biomass confirmed the presence of active functional groups that participate in the binding of As(III). Scanning Electron Microscopy (SEM) indulged the surface morphology of modified electrode-biosensor before and after As(III) adsorption. Similarly, Atomic Force Microscopy (AFM) showed that the average roughness of the modified electrode decreased indicating the successful incorporation of P. cruentum biomass. Efficiency of the biosensor in the presence of different interfering metal (Na+, K+, Ca2+, and Mg2+) ions were also evaluated. The application of P. cruentum modified biosensor was successfully used for the detection of As(III) in the binary metal (Fe3+, Mn2+, Cd2+, Cu2+, Ni2+, Hg2+, and Pb2+) contaminated system. The accuracy of application of biosorption based biosensor for the detection of As(III) is as low as 2.5 mu g L-1. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [41] VOLTAMMETRIC DETERMINATION OF CADMIUM ON A CARBON PASTE ELECTRODE MODIFIED WITH A CHELATING RESIN
    AGRAZ, R
    SEVILLA, MT
    PINILLA, JM
    HERNANDEZ, L
    ELECTROANALYSIS, 1991, 3 (4-5) : 393 - 397
  • [42] Cyclic Voltammetric Investigations of Dopamine at Alizarin Modified Carbon Paste Electrode
    Mahanthesha, K. R.
    Swamy, B. E. Kumara
    Pai, K. Vasantakumar
    Chandra, Umesh
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (12): : 1962 - 1971
  • [43] Cyclic Voltammetric Investigation of Caffeine at Anthraquinone Modified Carbon Paste Electrode
    Tadesse, Yemane
    Tadese, Abraha
    Saini, R. C.
    Pal, Rishi
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2013, 2013
  • [44] Voltammetric sensing of thallium at a carbon paste electrode modified with a crown ether
    Somayye Cheraghi
    Mohammad Ali Taher
    Hamid Fazelirad
    Microchimica Acta, 2013, 180 : 1157 - 1163
  • [45] Voltammetric determination of mifepristone at a DNA-modified carbon paste electrode
    Gu, K
    Zhu, JJ
    Zhu, YL
    Xu, JZ
    Chen, HY
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08): : 832 - 835
  • [46] MEDIATED AMPEROMETRIC BIOSENSOR FOR HYPOXANTHINE BASED ON A HYDROXYMETHYLFERROCENE-MODIFIED CARBON PASTE ELECTRODE
    OKUMA, H
    TAKAHASHI, H
    SEKIMUKAI, S
    ANALYTICA CHIMICA ACTA, 1991, 244 (02) : 161 - 164
  • [47] Glucose biosensor based on the use of a carbon nanotube paste electrode modified with metallic particles
    Luque, GL
    Ferreyra, NF
    Rivas, GA
    MICROCHIMICA ACTA, 2006, 152 (3-4) : 277 - 283
  • [48] Glucose Biosensor Based on the Use of a Carbon Nanotube Paste Electrode Modified with Metallic Particles
    Guillermina L. Luque
    Nancy F. Ferreyra
    Gustavo A. Rivas
    Microchimica Acta, 2006, 152 : 277 - 283
  • [49] Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode
    Jing Bai
    Jean Chrysostome Ndamanisha
    Lin Liu
    Li Yang
    Liping Guo
    Journal of Solid State Electrochemistry, 2010, 14 : 2251 - 2256
  • [50] Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode
    Bai, Jing
    Ndamanisha, Jean Chrysostome
    Liu, Lin
    Yang, Li
    Guo, Liping
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (12) : 2251 - 2256