Voltammetric detection of As(III) with Porphyridium cruentum based modified carbon paste electrode biosensor

被引:25
|
作者
Zaib, M. [1 ,2 ]
Saeed, A. [1 ]
Hussain, I. [3 ]
Athar, M. M. [2 ]
Iqbal, M. [1 ,4 ]
机构
[1] Food & Biotechnol Res Ctr, Lahore 54600, Pakistan
[2] Univ Punjab, Inst Chem, Lahore 54590, Pakistan
[3] Lahore Univ Management Sci, Sch Sci & Engn, Dept Chem, Lahore 54792, Pakistan
[4] Ctr Appl Mol Biol, Lahore 53700, Pakistan
来源
关键词
As(III); Red alga; Modified carbon paste electrode; Voltammetry; FTIR; ANODIC-STRIPPING VOLTAMMETRY; DRINKING-WATER; ELECTROCHEMICAL DETECTION; MICROBIAL BIOSENSOR; ARSENIC(III); REMOVAL; BIOSORPTION; CADMIUM; RED; SPECIATION;
D O I
10.1016/j.bios.2014.06.055
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel biosensor based on carbon paste electrode modified with Porphyridium cruentum biomass was developed for the determination of As(III) in contaminated water. As(III) was first biosorbed-accumulated on the electrode surface at open circuit potential and then stripped off by applying anodic scan range of -0.8 to +0.8 V using differential pulse anodic stripping voltammetric technique. The best result was obtained at pH 6.0 with 0.1 M HNO3 solution as stripping medium, allowing biosorption-accumulation time of 8 min using 5% P. cruentum biomass in graphite-mineral oil paste. Linear range for As(III) detection with the modified electrode-biosensor was observed between 2.5 and 20 mu g L-1. The FTIR spectrum of P. cruentum biomass confirmed the presence of active functional groups that participate in the binding of As(III). Scanning Electron Microscopy (SEM) indulged the surface morphology of modified electrode-biosensor before and after As(III) adsorption. Similarly, Atomic Force Microscopy (AFM) showed that the average roughness of the modified electrode decreased indicating the successful incorporation of P. cruentum biomass. Efficiency of the biosensor in the presence of different interfering metal (Na+, K+, Ca2+, and Mg2+) ions were also evaluated. The application of P. cruentum modified biosensor was successfully used for the detection of As(III) in the binary metal (Fe3+, Mn2+, Cd2+, Cu2+, Ni2+, Hg2+, and Pb2+) contaminated system. The accuracy of application of biosorption based biosensor for the detection of As(III) is as low as 2.5 mu g L-1. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [31] Chemically-modified carbon paste electrode for the voltammetric determination of bismuth
    Ferri, T
    Paci, S
    Morabito, R
    ANNALI DI CHIMICA, 1996, 86 (5-6) : 245 - 256
  • [32] A VOLTAMMETRIC TECHNIQUE USING A MODIFIED CARBON PASTE ELECTRODE FOR THE DETERMINATION OF ACLONIFEN
    Novotny, Vit
    Barek, Jiri
    ECOLOGICAL CHEMISTRY AND ENGINEERING S-CHEMIA I INZYNIERIA EKOLOGICZNA S, 2015, 22 (03): : 451 - 458
  • [33] Catalytic voltammetric determination of molybdenum at a chemically modified carbon paste electrode
    Gao, ZQ
    Siow, KS
    Ng, A
    ELECTROANALYSIS, 1996, 8 (12) : 1183 - 1187
  • [34] Voltammetric determination of hydrochlorothiazide at a modified carbon paste electrode with polypyrrole nanotubes
    Mohammadnavaz, Arefeh
    Garkani-Nejad, Fariba
    ADMET AND DMPK, 2023, 11 (02): : 293 - 302
  • [35] Voltammetric determination of mifepristone at a DNA-modified carbon paste electrode
    K. Gu
    J. Zhu
    Y. Zhu
    J. Xu
    H.-Y. Chen
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 832 - 835
  • [36] VOLTAMMETRIC DETERMINATION OF GOLD USING A CARBON PASTE ELECTRODE MODIFIED WITH THIOBENZANILIDE
    CAI, XH
    KALCHER, K
    NEUHOLD, C
    DIEWALD, W
    MAGEE, RJ
    ANALYST, 1993, 118 (01) : 53 - 57
  • [37] MODIFIED CARBON-PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF TRACE SILICON
    GURENTSOVA, OI
    PROKHOROVA, GV
    OSIPOVA, EA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (09) : 1224 - 1228
  • [38] Voltammetric determination terbinafine at carbon paste electrode modified with graphene nanosheets
    Hendawy, Hassan A. M.
    Radowan, Abdellatef A.
    Khaled, Elmorsy
    EGYPTIAN JOURNAL OF CHEMISTRY, 2023, 66 (03): : 103 - 112
  • [39] VOLTAMMETRIC DETERMINATION OF LINURON AT A CARBON-PASTE ELECTRODE MODIFIED WITH SEPIOLITE
    HERNANDEZ, P
    VICENTE, J
    GONZALEZ, M
    HERNANDEZ, L
    TALANTA, 1990, 37 (08) : 789 - 794
  • [40] Voltammetric sensing of thallium at a carbon paste electrode modified with a crown ether
    Cheraghi, Somayye
    Taher, Mohammad Ali
    Fazelirad, Hamid
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1157 - 1163