Analysis of sulfides in whole rock matrices by elemental analyzer-continuous flow isotope ratio mass spectrometry

被引:83
|
作者
Studley, SA [1 ]
Ripley, EM [1 ]
Elswick, ER [1 ]
Dorais, MJ [1 ]
Fong, J [1 ]
Finkelstein, D [1 ]
Pratt, LM [1 ]
机构
[1] Indiana Univ, Dept Geol Sci, Bloomington, IN 47405 USA
基金
美国国家科学基金会;
关键词
delta S-34 measurements; elemental analyzer-continuous-flow isotope ratio mass spectrometry; whole rock analyses; matrix effects;
D O I
10.1016/S0009-2541(02)00162-6
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Potential matrix effects in the sulfur isotopic analysis of whole rocks by elemental analyzer-continuous-flow isotope ratio mass spectrometry (EA-CFIRMS) have been investigated by measuring mixtures of a well-calibrated laboratory sulfide reference mineral and common rock-forming minerals. Mixtures of sulfide and quartz, orthoclase, plagioclase, kaolinite, olivine, magnetite, ilmenite, garnet, halite, fluorite, calcite, and graphite show consistent S yields and delta(34)S values generally within +/- 0.2parts per thousand of the measured pure sulfide value. However, erratic results are obtained for mixtures of reference sulfide and pyroxene, amphibole, or biotite. These minerals may suppress sample peaks, cause extreme peak tailing, and prohibit isotope ratio measurements. Pure sulfide minerals introduced after the mixtures also showed suppressed sample peaks, suggesting SO2 adsorption on mineral and residual ash surfaces. Removal of the residual ash resulted in normal measurements for reference sulfide minerals. Whole rocks with S concentrations in excess of similar to 100 ppm can be successfully analyzed using EA-CFIRMS provided that measurements are carefully monitored for evidence of SO2 retention during and after combustion. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [11] On-line nitrate-δ15N extracted from groundwater determined by continuous-flow elemental analyzer/isotope ratio mass spectrometry
    Stickrod, RD
    Marshall, JD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (14) : 1266 - 1268
  • [12] A Refinement of Nitrogen Isotope Analysis of Coal Using Elemental Analyzer/Isotope Ratio Mass Spectrometry and the Carbon and Nitrogen Isotope Compositions of Coals Imported in China
    Feng, Lianjun
    Li, Hongwei
    Yan, Detian
    [J]. ACS OMEGA, 2020, 5 (13): : 7636 - 7640
  • [13] Detection of royal jelly adulteration using elemental analyzer-carbon isotope ratio mass spectrometry
    Fei, Xiao-Qing
    Shen, Chong-Yu
    Wu, Bin
    Zhang, Rui
    Ding, Tao
    Zhang, Xiao-Yan
    Chen, Lei
    [J]. Journal of Chinese Mass Spectrometry Society, 2014, 35 (02) : 144 - 148
  • [14] Experimental assessment of elemental analyzer isotope ratio mass spectrometry normalization methodologies for environmental stable isotopes
    Balint, Sawyer
    Schwartz, Morgan
    Fowler, Drew N.
    Linnekogel, Stella
    Clemons, Sade Cromratie
    Burkemper, Laura K.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (17)
  • [15] Stable chlorine isotope ratio analysis of subnanomolar level methyl chloride by continuous-flow isotope ratio mass spectrometry
    Konno, Uta
    Takai, Ken
    Kawagucci, Shinsuke
    [J]. GEOCHEMICAL JOURNAL, 2013, 47 (04) : 469 - 473
  • [16] Triple oxygen stable isotope analysis of nitrite measured using continuous flow isotope ratio mass spectrometry *
    Walters, Wendell W.
    Hastings, Meredith G.
    [J]. METHODSX, 2023, 11
  • [17] Evaluation on nitrogen isotopes analysis in high-C/N-ratio plants using elemental analyzer/isotope ratio mass spectrometry
    胡婧
    刘卫国
    [J]. Nuclear Science and Techniques, 2014, 25 (02) : 39 - 42
  • [18] Evaluation on nitrogen isotopes analysis in high-C/N-ratio plants using elemental analyzer/isotope ratio mass spectrometry
    Hu Jing
    Liu Wei-Guo
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2014, 25 (02)
  • [19] High-precision continuous-flow isotope ratio mass spectrometry
    Brenna, JT
    Corso, TN
    Tobias, HJ
    Caimi, RJ
    [J]. MASS SPECTROMETRY REVIEWS, 1997, 16 (05) : 227 - 258
  • [20] RECENT PROGRESS IN CONTINUOUS-FLOW ISOTOPE RATIO MASS-SPECTROMETRY
    PRESTON, T
    BARRIE, A
    [J]. AMERICAN LABORATORY, 1991, 23 (18) : H32 - &