Fast optimization and dose calculation in scanned ion beam therapy

被引:7
|
作者
Hild, S. [1 ,2 ,3 ,4 ]
Graeff, C. [5 ]
Trautmann, J. [5 ]
Kraemer, M. [5 ]
Zink, K. [4 ,6 ]
Durante, M. [5 ,7 ]
Bert, C. [2 ,3 ,5 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64291 Darmstadt, Germany
[2] Univ Clin Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, D-91054 Erlangen, Germany
[4] Univ Appl Sci, Inst Med Phys & Radiat Protect, D-35390 Giessen, Germany
[5] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64289 Darmstadt, Germany
[6] Univ Hosp Giessen Marburg, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
[7] Tech Univ Darmstadt, Fac Phys, D-64289 Darmstadt, Germany
关键词
particle therapy; prostate cancer; adaptive treatment planning; fast dose calculation; RADIOTHERAPY; SYSTEM; CT; DESIGN; TUMORS; MODEL;
D O I
10.1118/1.4881522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors
    Hild, Sebastian
    Durante, Marco
    Bert, Christoph
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 528 - 535
  • [42] Scintillator screen for measuring dose distribution in scanned carbon-ion therapy
    Yogo, Katsunori
    Tatsuno, Yuya
    Souda, Hikaru
    Matsumura, Akihiko
    Tsuneda, Masato
    Hirano, Yoshiyuki
    Ishiyama, Hiromichi
    Saito, Akito
    Ozawa, Shuichi
    Nagata, Yasushi
    Nakano, Takashi
    Hayakawa, Kazushige
    Kanai, Tatsuaki
    RADIATION MEASUREMENTS, 2019, 129
  • [43] Robustness Against Interfraction Prostate Movement in Scanned Ion Beam Radiation Therapy
    Jelen, Urszula
    Ammazzalorso, Filippo
    Chanrion, Marie-Anne
    Graef, Sebastian
    Zink, Klemens
    Engenhart-Cabillic, Rita
    Wittig, Andrea
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02): : E257 - E262
  • [44] Gating window dependency on scanned carbon-ion beam dose distribution and imaging dose for thoracoabdominal treatment
    Mori, Shinichiro
    Karube, Masataka
    Yasuda, Shigeo
    Yamamoto, Naoyoshi
    Tsuji, Hiroshi
    Kamada, Tadashi
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1074):
  • [45] A fast dose calculation method including scatter for IMRT optimization
    Wu, Q
    MEDICAL PHYSICS, 2004, 31 (06) : 1854 - 1855
  • [46] Light dose calculation and optimization for prostate photodynamic therapy
    Zhu, TC
    Altschuler, M
    Xiao, Y
    Finlay, J
    Dimofte, A
    Hahn, SM
    MEDICAL PHYSICS, 2003, 30 (06) : 1336 - 1336
  • [47] Validation of Beam Modeling and Dose Calculation of Proton Beam Therapy for Monaco TPS
    Chen, S.
    Li, X.
    Zhao, L.
    Deraniyagala, R.
    Zheng, W.
    Qin, A.
    Ding, X.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1523 - S1524
  • [48] Radiotherapy with a scanned carbon ion beam at GSI
    Jäkel, O
    Heeg, P
    Karger, CP
    Krämer, M
    Schulz-Ertner, D
    Debus, J
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S80 - S80
  • [49] Tumor tracking based on correlation models in scanned ion beam therapy: an experimental study
    Seregni, M.
    Kaderka, R.
    Fattori, G.
    Riboldi, M.
    Pella, A.
    Constantinescu, A.
    Saito, N.
    Durante, M.
    Cerveri, P.
    Bert, C.
    Baroni, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : 4659 - 4678
  • [50] Fast RBE-Corrected Dose Calculation for Carbon Therapy
    Veltchev, I.
    Fourkal, E.
    Fan, J.
    Li, J.
    Ma, C.
    MEDICAL PHYSICS, 2010, 37 (06) : 3354 - +