Robustness Against Interfraction Prostate Movement in Scanned Ion Beam Radiation Therapy

被引:10
|
作者
Jelen, Urszula [1 ,4 ]
Ammazzalorso, Filippo [1 ]
Chanrion, Marie-Anne [1 ,2 ,3 ]
Graef, Sebastian [1 ]
Zink, Klemens [4 ]
Engenhart-Cabillic, Rita [1 ]
Wittig, Andrea [1 ]
机构
[1] Univ Marburg, Dept Radiotherapy & Radiat Oncol, Marburg, Germany
[2] Univ Lyon 1, F-69365 Lyon, France
[3] Univ Appl Sci, Giessen, Germany
[4] Univ Med Ctr Giessen & Marburg, Dept Radiotherapy & Radiat Oncol, D-35043 Marburg, Germany
关键词
PROTON THERAPY; CANCER TREATMENT; BONY ANATOMY; ONLINE; RADIOTHERAPY; MOTION; ERRORS;
D O I
10.1016/j.ijrobp.2012.03.058
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the robustness of scanned ion beam treatment plans against the interfraction internal target motion and evaluate the limits of validity of target-based isocenter realignment for prostate cancer radiation therapy. Methods and Materials: For 12 prostate patients, scanned beam carbon ion treatment plans were prepared using 2 lateral opposed beams and the raster scanning technique with different clinical target volume (CTV) to planning target volume (PTV) margins (2-10 mm). Internal target motion of 2-15 mm in anteroposterior (AP), superoinferior (SI), and left-to-right (LR) directions was simulated by displacing the CTV contours with respect to the computed tomography data. The plans were recalculated with and without target-based isocenter realignment and the CTV coverage was assessed. Results: For CTV shifts within the applied planning margin, the CI-98% is greater than 98.0%, both with and without isocenter realignment. Without realignment, because of the sharp lateral gradients, the CI-98% shows rapid fall as soon as the target shift exceeds the applied planning margin for all displacement directions. With isocenter realignment, the coverage improves notably for shifts in AP and SI directions and the CI-98% is restored to >95.0% for plans optimized with a 2-mm margin, >97% with a 3-mm margin, and >98% with larger margins. For large corrections, predominately in AP direction, cold spots in the CTV may occur. Their magnitude is dependent on the patients' individual anatomies. Conclusions: Within the physiological limits of internal prostate movement, target-based isocenter realignment results in improved CTV coverage for shifts in AP and SI directions exceeding the applied planning margin. Assuming optimal patient setup reproducibility (eg, immobilization, setup error correction, patient preparation protocols), hence negligible interfraction bone and soft-tissue variations, changes in traversed densities resulting from target-based realignment applied with a reduced planning margin do not induce significant dose deterioration in most of the cases. (C) 2012 Elsevier Inc.
引用
收藏
页码:E257 / E262
页数:6
相关论文
共 50 条
  • [1] Scanned ion beam therapy for prostate carcinoma
    Hild, Sebastian
    Graeff, Christian
    Rucinski, Antoni
    Zink, Klemens
    Habl, Gregor
    Durante, Marco
    Herfarth, Klaus
    Bert, Christoph
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 118 - 126
  • [2] ROBUSTNESS AGAINST THE INTERFRACTIONAL INTERNAL TARGET MOVEMENT IN ION BEAM RADIOTHERAPY PROSTATE TREATMENT PLANNING
    Graef, S.
    Jelen, U.
    Ammazzalorso, F.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S61 - S61
  • [3] Robustness of 4D-optimized scanned carbon ion beam therapy against interfractional changes in lung cancer
    Graeff, Christian
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (03) : 387 - 392
  • [4] A study of interfraction organ motion during radiation therapy for prostate cancer
    Jenkins, T
    Fish, K
    Wolfe, M
    Sibata, C
    Allison, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1859 - 1859
  • [5] The Dosimetric Impact of Interfraction Anorectum and Bladder Variability in Prostate Radiation Therapy
    Patel, V.
    Chinea, F.
    Abramowitz, M.
    Studenski, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3422 - 3422
  • [6] Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Richter, Daniel
    Luechtenborg, Robert
    Saito, Nami
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1717 - 1740
  • [7] Management of organ motion in scanned ion beam therapy
    Christoph Bert
    Klaus Herfarth
    Radiation Oncology, 12
  • [8] Management of organ motion in scanned ion beam therapy
    Bert, Christoph
    Herfarth, Klaus
    RADIATION ONCOLOGY, 2017, 12
  • [9] Adjustment procedure for beam alignment in scanned ion-beam therapy
    Saraya, Y.
    Takeshita, E.
    Furukawa, T.
    Hara, Y.
    Mizushima, K.
    Saotome, N.
    Tansho, R.
    Shirai, T.
    Noda, K.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (06) : 948 - 952
  • [10] Adjustment procedure for beam alignment in scanned ion-beam therapy
    Y. Saraya
    E. Takeshita
    T. Furukawa
    Y. Hara
    K. Mizushima
    N. Saotome
    R. Tansho
    T. Shirai
    K. Noda
    Journal of the Korean Physical Society, 2016, 69 : 948 - 952