Comparison of additional pseudophakic multifocal lenses and multifocal intraocular lens in the capsular bag

被引:9
|
作者
Schrecker, J. [1 ]
Feith, A. [1 ]
Langenbucher, A. [2 ]
机构
[1] Rudolf Virchow Klinikum Glauchau, Dept Ophthalmol, D-08371 Glauchau, Germany
[2] Univ Saarland, Chair Expt Ophthalmol, Homburg, Germany
关键词
CONTRAST SENSITIVITY; IMPLANTATION;
D O I
10.1136/bjophthalmol-2013-304591
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To compare the clinical results and the intraoperative and postoperative performance of an additional sulcus-fixated multifocal intraocular lens (IOL) with a conventional multifocal IOL implanted in the capsular bag. Methods In this prospective, randomised, monocentric study, the intraoperative and postoperative outcomes after implantation of an additional sulcus-fixated multifocal IOL (group A; 29 eyes) and a conventional, multifocal posterior chamber IOL (group B; 25 eyes) are compared. 1-year postoperatively, visual acuity, contrast sensitivity and defocus curve were determined. Patients implanted bilaterally with the same IOL filled in a questionnaire to assess patient satisfaction. Results Between the groups, only slight differences were found in visual acuity at all distances. All patients achieved an uncorrected distance visual acuity of 0.1 LogMAR or better and an uncorrected intermediate/near visual acuity of 0.3 LogMAR or better. Slightly better results in contrast sensitivity were achieved in group A at high spatial frequencies under almost all lighting conditions. Patient survey showed a higher degree of satisfaction of patients in group B, while a smaller proportion of group A stated to have disturbing light phenomena. Conclusions Only small functional differences between the examined methods were found. Both types of multifocal IOL performed well at all distances. There were no intraoperative and postoperative complications in the add-on IOL group which affirms the high safety level such as with conventional multifocal IOL in the capsular bag.
引用
收藏
页码:915 / 919
页数:5
相关论文
共 50 条
  • [41] CONTRAST SENSITIVITY IN MULTIFOCAL INTRAOCULAR LENSES
    RAVALICO, G
    BACCARA, F
    RINALDI, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01): : 22 - 25
  • [42] Multifocal intraocular lenses in the setting of glaucoma
    Kumar, B. Vineeth
    Phillips, Russell P.
    Prasad, Somdutt
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) : 62 - 66
  • [43] Halos in refractive multifocal intraocular lenses
    Pieh, S
    Zöhrer, R
    Backner, B
    Hanselmayer, G
    Ruhswurm, I
    Scholz, U
    Weghaupt, H
    Skorpik, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S298 - S298
  • [44] Visual function comparison of 2 aspheric multifocal intraocular lenses
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Blazquez, Jose I.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 242 - 248
  • [45] EVALUATING MULTIFOCAL INTRAOCULAR LENSES - REPLY
    HOLLADAY, JT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (06): : 776 - 777
  • [46] Vision with bifocal and multifocal intraocular lenses
    Kirschfeld, K.
    Land, M. F.
    OPHTHALMOLOGE, 2011, 108 (12): : 1139 - 1144
  • [47] MULTIFOCAL INTRAOCULAR LENSES - BETTER OR WORSE
    KAUFMAN, HE
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (04) : 424 - 425
  • [48] Multifocal intraocular lenses with fractal geometry
    Remon, L.
    Furlan, W. D.
    Monsoriu, J. A.
    OPTICA PURA Y APLICADA, 2015, 48 (01): : 1 - 8
  • [49] Optical performance of multifocal intraocular lenses
    Jacobi, F. K.
    Kessler, W.
    Held, S.
    OPHTHALMOLOGE, 2007, 104 (03): : 236 - 242
  • [50] Comparison of ocular straylight after implantation of multifocal intraocular lenses
    Labuz, Grzegorz
    Reus, Nicolaas J.
    van den Berg, Thomas J. T. P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 618 - 625