Radiation exposure dose of fluoroscopy-guided gastrointestinal procedures: A single-center retrospective study

被引:13
|
作者
Hayashi, Shiro [1 ,2 ]
Nishida, Tsutomu [1 ]
Kuriki, Shinji [1 ]
Chang, Li-sa [1 ]
Aochi, Kazuki [1 ]
Meren, Emi [1 ]
Sakamoto, Tatsuya [1 ]
Tomita, Ryo [1 ]
Higaki, Yu [1 ]
Osugi, Naoto [1 ]
Sugimoto, Aya [1 ]
Takahashi, Kei [1 ]
Mukai, Kaori [1 ]
Matsumoto, Kengo [1 ]
Nakamatsu, Dai [1 ]
Yamamoto, Masahi [1 ]
Fukui, Koji [1 ]
Takenaka, Mamoru [3 ]
Hosono, Makoto [4 ]
Inada, Masami [1 ]
机构
[1] Toyonaka City Hosp, Dept Gastroenterol, 4-14-1 Shibahara, Toyonaka, Osaka 5608565, Japan
[2] Hayashi Clin, Dept Gastroenterol & Internal Med, Osaka, Japan
[3] Kindai Univ, Dept Gastroenterol & Hepatol, Fac Med, Osaka, Japan
[4] Kindai Univ, Dept Radiol, Fac Med, Osaka, Japan
关键词
DIAGNOSTIC REFERENCE LEVELS; BILIARY INTERVENTIONS; IONIZING-RADIATION; PROTECTION;
D O I
10.1055/a-1287-9066
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims Fluoroscopy-guided gastrointestinal procedures (FGPs) are increasingly common. However, the radiation exposure (RE) to patients undergoing FGPs is still unclear. We examined the actual RE of FGPs. Patients and methods This retrospective, single-center cohort study included consecutive FGPs, including endoscopic retrograde cholangiopancreatography (ERCP), interventional endoscopic ultrasound (EUS), enteral stenting, balloon-assisted enteroscopy, tube placement, endoscopic injection sclerotherapy (EIS), esophageal balloon dilatation and repositioning for sigmoid volvulus, from September 2012 to June 2019. We measured the air kerma (AK, mGy), dose area product (DAP, Gycm(2)), and fluoroscopy time (FT, min) for each procedure. Results In total, 3831 patients were enrolled. Overall, 2778 ERCPs were performed. The median AK, DAP, and FT were as follows: ERCP: 109mGy, 13.3Gycm(2) and 10.0min; self-expandable enteral stenting (SEMS): 62mGy, 12.4 Gycm(2) and 10.4min; tube placement: 40mGy, 13.8 Gycm(2) and 11.1 min; balloon- assisted enteroscopy: 43mGy, 22.4Gycm(2) and 18.2min; EUS cyst drainage (EUS-CD): 96mGy, 18.3Gycm(2) and 10.4min; EIS: 36mGy, 8.1 Gycm(2) and 4.4 min; esophageal balloon dilatation: 9 mGy, 2.2 Gycm(2) and 1.8 min; and repositioning for sigmoid volvulus: 7mGy, 4.7Gycm(2) and 1.6 min. Conclusion This large series reporting actual RE doses of various FGPs could serve as a reference for future prospective studies.
引用
下载
收藏
页码:E1872 / E1877
页数:6
相关论文
共 50 条
  • [1] Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures
    Roman Kloeckner
    Anton Bersch
    Daniel Pinto dos Santos
    Jens Schneider
    Christoph Düber
    Michael Bernhard Pitton
    CardioVascular and Interventional Radiology, 2012, 35 : 613 - 620
  • [2] Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures
    Kloeckner, Roman
    Bersch, Anton
    dos Santos, Daniel Pinto
    Schneider, Jens
    Dueber, Christoph
    Pitton, Michael Bernhard
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (03) : 613 - 620
  • [3] Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings
    Zweers, D
    Geleijns, J
    Aarts, NJM
    Hardam, LJ
    Laméris, JS
    Scultz, FW
    Kool, LJS
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846): : 672 - 676
  • [4] CT fluoroscopy-guided interventional procedures: Techniques and radiation dose to radiologists
    Paulson, EK
    Sheafor, DH
    Enterline, DS
    McAdams, HP
    Yoshizumi, TT
    RADIOLOGY, 2001, 220 (01) : 161 - 167
  • [5] Influence of resident involvement on fluoroscopy time and ionizing radiation exposure in fluoroscopy-guided spinal procedures
    Soucy, Beatrice
    Lee, Dillon
    Moreau-Bourbonnais, Amelie
    Filiatrault, Marc
    Denis, Isabelle
    Chang, Min Cheol
    Boudier-Reveret, Mathieu
    PM&R, 2024, 16 (03) : 260 - 267
  • [6] Use of Artificial Intelligence to Reduce Radiation Exposure at Fluoroscopy-Guided Endoscopic Procedures
    Bang, Ji Young
    Hough, Matthew
    Hawes, Robert H.
    Varadarajulu, Shyam
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 (04): : 555 - 561
  • [7] Single-center review of fluoroscopy-guided percutaneous nephrostomy performed by urologic surgeons
    Rana, Abdul Majid
    Zaidi, Zafar
    Salman-El-Khalid
    JOURNAL OF ENDOUROLOGY, 2007, 21 (07) : 688 - 691
  • [8] Patient radiation dose and fluoroscopy time during ERCP: a single-center, retrospective study of influencing factors
    Saukko, Ekaterina
    Gronroos, Juha M.
    Salminen, Paulina
    Henner, Anja
    Nieminen, Miika T.
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2018, 53 (04) : 495 - 504
  • [9] How should radiation exposure be handled in fluoroscopy-guided endoscopic procedures in the field of gastroenterology?
    Takenaka, Mamoru
    Hosono, Makoto
    Hayashi, Shiro
    Nishida, Tsutomu
    Kudo, Masatoshi
    DIGESTIVE ENDOSCOPY, 2022, 34 (05) : 890 - 900
  • [10] Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures
    Jung, Cheol Hee
    Ryu, Jae Sung
    Baek, Seung Woo
    Oh, Ji Hye
    Woo, Nam Sik
    Kim, Hae Kyoung
    Kim, Jae Hun
    KOREAN JOURNAL OF PAIN, 2013, 26 (01): : 51 - 56