Radiation exposure dose of fluoroscopy-guided gastrointestinal procedures: A single-center retrospective study

被引:13
|
作者
Hayashi, Shiro [1 ,2 ]
Nishida, Tsutomu [1 ]
Kuriki, Shinji [1 ]
Chang, Li-sa [1 ]
Aochi, Kazuki [1 ]
Meren, Emi [1 ]
Sakamoto, Tatsuya [1 ]
Tomita, Ryo [1 ]
Higaki, Yu [1 ]
Osugi, Naoto [1 ]
Sugimoto, Aya [1 ]
Takahashi, Kei [1 ]
Mukai, Kaori [1 ]
Matsumoto, Kengo [1 ]
Nakamatsu, Dai [1 ]
Yamamoto, Masahi [1 ]
Fukui, Koji [1 ]
Takenaka, Mamoru [3 ]
Hosono, Makoto [4 ]
Inada, Masami [1 ]
机构
[1] Toyonaka City Hosp, Dept Gastroenterol, 4-14-1 Shibahara, Toyonaka, Osaka 5608565, Japan
[2] Hayashi Clin, Dept Gastroenterol & Internal Med, Osaka, Japan
[3] Kindai Univ, Dept Gastroenterol & Hepatol, Fac Med, Osaka, Japan
[4] Kindai Univ, Dept Radiol, Fac Med, Osaka, Japan
关键词
DIAGNOSTIC REFERENCE LEVELS; BILIARY INTERVENTIONS; IONIZING-RADIATION; PROTECTION;
D O I
10.1055/a-1287-9066
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims Fluoroscopy-guided gastrointestinal procedures (FGPs) are increasingly common. However, the radiation exposure (RE) to patients undergoing FGPs is still unclear. We examined the actual RE of FGPs. Patients and methods This retrospective, single-center cohort study included consecutive FGPs, including endoscopic retrograde cholangiopancreatography (ERCP), interventional endoscopic ultrasound (EUS), enteral stenting, balloon-assisted enteroscopy, tube placement, endoscopic injection sclerotherapy (EIS), esophageal balloon dilatation and repositioning for sigmoid volvulus, from September 2012 to June 2019. We measured the air kerma (AK, mGy), dose area product (DAP, Gycm(2)), and fluoroscopy time (FT, min) for each procedure. Results In total, 3831 patients were enrolled. Overall, 2778 ERCPs were performed. The median AK, DAP, and FT were as follows: ERCP: 109mGy, 13.3Gycm(2) and 10.0min; self-expandable enteral stenting (SEMS): 62mGy, 12.4 Gycm(2) and 10.4min; tube placement: 40mGy, 13.8 Gycm(2) and 11.1 min; balloon- assisted enteroscopy: 43mGy, 22.4Gycm(2) and 18.2min; EUS cyst drainage (EUS-CD): 96mGy, 18.3Gycm(2) and 10.4min; EIS: 36mGy, 8.1 Gycm(2) and 4.4 min; esophageal balloon dilatation: 9 mGy, 2.2 Gycm(2) and 1.8 min; and repositioning for sigmoid volvulus: 7mGy, 4.7Gycm(2) and 1.6 min. Conclusion This large series reporting actual RE doses of various FGPs could serve as a reference for future prospective studies.
引用
下载
收藏
页码:E1872 / E1877
页数:6
相关论文
共 50 条
  • [31] Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures
    Vano, Eliseo
    Loose, Reinhard
    Frija, Guy
    Paulo, Graciano
    Efstathopoulos, Efstathios
    Granata, Claudio
    Corridori, Riccardo
    Torresin, Alberto
    Andersson, Jonas S.
    Tsapaki, Virginia
    Ammon, Josefin
    Hoeschen, Christoph
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5525 - 5531
  • [32] Radiation exposure and its reduction in the fluoroscopic examination and fluoroscopy-guided interventional radiology
    Jeong, Woo Kyoung
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2011, 54 (12): : 1269 - 1276
  • [33] Radiation exposure in fluoroscopy-guided anterior total hip arthroplasty: a systematic review
    Nayeem Baksh
    Lulu Wei
    Elver S. Ho
    Jack J. Zhou
    Nicholas D. Stekas
    Ahmed M. Eldib
    Qais Naziri
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 891 - 897
  • [34] Radiation Exposure during Fluoroscopy-Guided Ozone Chemonucleolysis for Lumbar Disc Herniation
    Leoni, Matteo Luigi Giuseppe
    Vitali, Sara
    Micheli, Fabrizio
    Mercieri, Marco
    Varrassi, Giustino
    Casale, Roberto
    Occhigrossi, Felice
    Giordano, Carlo
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [35] Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring
    Sailer, Anna M.
    Vergoossen, Laura
    Paulis, Leonie
    van Zwam, Willem H.
    Das, Marco
    Wildberger, Joachim E.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (11) : 1756 - 1762
  • [36] Improved fluoroscopy-guided biopsies in the diagnosis of indeterminate biliary strictures: a multi-center retrospective study
    Xiong, Zhe
    Wang, Kuangjing
    Zhang, Huahui
    Fang, Ying
    Li, Fengdong
    Huang, Jin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [37] Improved fluoroscopy-guided biopsies in the diagnosis of indeterminate biliary strictures: a multi-center retrospective study
    Zhe Xiong
    Kuangjing Wang
    Huahui Zhang
    Ying Fang
    Fengdong Li
    Jin Huang
    Scientific Reports, 13
  • [38] FLUOROSCOPY-GUIDED BILIARY PROCEDURES IN A PREGNANT, LIVER TRANSPLANT PATIENT: FETUS RADIATION PROTECTION
    Gerasia, R.
    Cannataci, C.
    Gallo, G. S.
    Tafaro, C.
    Caruso, C.
    Maruzzelli, L.
    Miraglia, R.
    RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) : 396 - 401
  • [39] Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring
    Anna M. Sailer
    Laura Vergoossen
    Leonie Paulis
    Willem H. van Zwam
    Marco Das
    Joachim E. Wildberger
    Cécile R. L. P. N. Jeukens
    CardioVascular and Interventional Radiology, 2017, 40 : 1756 - 1762
  • [40] Radiation Dose to the Radiologist’s Hand During Continuous CT Fluoroscopy-Guided Interventions
    Beate M. Stoeckelhuber
    Thorsten Leibecke
    Edda Schulz
    Uwe H. Melchert
    Claudia U. Bergmann-Koester
    Thomas Helmberger
    Joerg Gellissen
    CardioVascular and Interventional Radiology, 2005, 28 : 589 - 594