Quantitative analysis of age-dependent backscatter factor (BSF) in x-ray examinations with a Monte Carlo method using XCAT phantoms

被引:0
|
作者
Park, Su-Jin [1 ]
Kim, Jaehyuk [1 ]
Huh, Yoonsuk [1 ]
Kim, Jung-Ha [1 ]
Kim, Jung-Min [1 ]
Park, Hyesuk [1 ]
Jo, JaeMoon [1 ]
机构
[1] Samsung Elect Co Ltd, Hlth & Med Equipment Business, Suwon, South Korea
关键词
Back scatter factor; BSF; Monte Carlo simulation; XCAT phantom; age-dependent; Quantitative analysis; ESD; pediatric patient;
D O I
10.1117/12.2292857
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The international organizations, including IAEA, have established a diagnostic reference levels (DRLs) for diagnostic x-ray examinations in order to control doses. The DRLs are mostly expressed as an entrance surface dose (ESD) to quantify dose on the patients. However, there are significant uncertainties associated with the measurements of ESD, and most of them are results from back scatter factor (BSF). The accurate BSF could be determined only by Monte Carlo simulations. In addition, as the human body is much more complicate compared with a commonly used ANSI phantom, for realistic simulation the computational anthropomorphic extended cardiac-torso (XCAT) phantom has to be used in order to obtain accurate BSF. However, to our knowledge, a few BSF values have previously been reported in the literature in x-ray examinations considering patients' age with XCAT phantom with Monte Carlo methods. The aim of this study was to quantitatively analyze the BSFs using XCAT phantom with Monte Carlo simulation in various x-ray examinations considering the patient's age. For chest examinations, the BSFs were 1.21, 1.29, and 1.35 for one-year old, seven-year old, and adult patient's protocol, respectively. For adult patient, the BSFs were 1.35, 1.26, and 1.10 for chest, abdomen, and extremity examinations, respectively. In addition, the ESDs in chest examinations were 36.30 mu Gy, 52.69 mu Gy, and 111.80 mu Gy for one-, seven-year old, and adult patient's protocol, respectively. These results demonstrated that accurate BSF should be chosen considering the diagnostic examination in order to estimate the ESD properly.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Patient radiation dose from x-ray guided endovascular aneurysm repair: a Monte Carlo approach using voxel phantoms and detailed exposure information
    Harbron, Richard W.
    Abdelhalim, Mohamed
    Ainsbury, Elizabeth A.
    Eakins, Jonathan S.
    Alam, Azeem
    Lee, Choonsik
    Modarai, Bijan
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) : 704 - 726
  • [42] Monte Carlo Simulation to Determine Geometry Effects on Quantitative X-ray Microanalysis in Plant Cell Walls Using Gelatin Standards
    Tylko, Grzegorz
    Dubchak, Sergyi
    Banach, Zuzanna
    Turnau, Katarzyna
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 93 - +
  • [43] A STANDARDLESS METHOD OF QUANTITATIVE MINERAL ANALYSIS USING X-RAY AND CHEMICAL-DATA
    ZANGALIS, KP
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1991, 24 : 197 - 202
  • [44] Photonic Material Selection of Scintillation Crystals Using Monte Carlo Method for X-Ray Detection in Industrial Computed Tomography
    He, Peng
    Wei, Biao
    Zhou, Mi
    Feng, Peng
    Chen, Mianyi
    JOURNAL OF SENSORS, 2014, 2014
  • [45] Bayesian Estimation of Thin-film X-ray Laue Oscillation Using Markov Chain Monte Carlo Method
    Sakishita, Yuki
    Nabeshima, Fuyuki
    Maeda, Atsutaka
    Hukushima, Koji
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2025, 94 (01)
  • [46] Assessment of scattered radiation from hand-held dental x-ray equipment using the Monte Carlo method
    Batista, Wilson Otto
    Soares, Maria Rosangela
    Gurjao Rios, Jacqueline Machado
    Dos Santos Souza, Antonio Carlos
    Pinheiro, Isabelle Matos
    Javier Vega Ramirez, Jose Luis
    Caldas, Linda V. E.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 654 - 668
  • [47] Analysis of extended x-ray absorption fine structure data from copper tungstate by the reverse Monte Carlo method
    Timoshenko, Janis
    Anspoks, Andris
    Kalinko, Aleksandr
    Kuzmin, Alexei
    PHYSICA SCRIPTA, 2014, 89 (04)
  • [48] Fast and accurate X-ray lithography simulation enabled by using Monte Carlo method. New version of DoseSim: a software dedicated to deep X-ray lithography (LIGA)
    Pascal Meyer
    Microsystem Technologies, 2012, 18 : 1971 - 1980
  • [49] Fast and accurate X-ray lithography simulation enabled by using Monte Carlo method. New version of DoseSim: a software dedicated to deep X-ray lithography (LIGA)
    Meyer, Pascal
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2012, 18 (12): : 1971 - 1980
  • [50] Reduction of radiation risks in patients undergoing some X-ray examinations by using optimal projections: A Monte Carlo program-based mathematical calculation
    Chaparian, A.
    Kanani, A.
    Baghbanian, M.
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 32 - 39