Parameters That Improve Cleaning Efficiency of Subgingival Air Polishing on Titanium Implant Surfaces: An In Vitro Study

被引:13
|
作者
Tastepe, Ceylin S. [1 ]
Lin, Xingnan [1 ,2 ]
Donnet, Marcel [3 ]
Wismeijer, Daniel [1 ]
Liu, Yuelian [1 ]
机构
[1] Res Inst MOVE, Acad Ctr Dent Amsterdam, Dept Oral Funct & Restorat Dent, Sect Oral Implantol & Prosthodont, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Netherlands
[2] Nanjing Univ, Affiliated Stomatol Hosp, Med Sch, Dept Orthodont, Nanjing, Jiangsu, Peoples R China
[3] EMS Electro Med Syst SA, Res Grp Dent, Nyon, Switzerland
关键词
Air abrasion; dental; dental implants; dental instruments; peri-implantitis; plaque removal; titanium; RANDOMIZED CLINICAL-TRIAL; ANTIINFECTIVE MECHANICAL THERAPY; PERI-IMPLANTITIS; GLYCINE-POWDER; ABRASIVE DEVICE; PLAQUE REMOVAL; NONSURGICAL TREATMENT; PERIODONTAL POCKETS; CYNOMOLGUS MONKEYS; SURGICAL-TREATMENT;
D O I
10.1902/jop.2016.160270
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: This study aims to reveal how air polishing behaves on a titanium surface by evaluating the size and shape of the cleaned area and the influence of different device settings, probing depths, and cleaning movements. Methods: Forty-eight titanium sandblasted large-grit acidetched surface film-coated disks were treated with an air abrasive system using a subgingival plastic nozzle. Two subgingival models were used: open-ended (step 1) and defined-size (step 2). In step 1, the most effective parameters were investigated by 5-second static applications under different settings. In step 2, the best settings were used for dynamic application to test influence of different movements (up-down, slowly up, rotation). For both steps, powder and water consumption and total cleaned area were calculated. Results: Air pressure was the main factor with the strongest effect on cleaning. Increasing air pressure extended cleaning area. Other factors, such as nozzle depth and excessive powder flow amount, had weak influence. Cleaning effect reached deeper than the nozzle physically reached. Step 2 showed that there was no significant difference between different nozzle movements; however, cleaning efficiency decreased significantly without movement. Conclusions: For the most effective clinical use of air polishing, it should be applied with high pressure, deep insertion of nozzle, and enough water flow. Additionally, the nozzle has to be moved to get the best cleaning effect.
引用
收藏
页码:407 / 414
页数:8
相关论文
共 50 条
  • [41] Bactericidal effects of different laser systems on bacteria adhered to dental implant surfaces: an in vitro study comparing zirconia with titanium
    Hauser-Gerspach, Irmgard
    Stuebinger, Stefan
    Meyer, Juerg
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (03) : 277 - 283
  • [42] The Effect of In Vitro Electrolytic Cleaning on Biofilm-Contaminated Implant Surfaces (vol 8, 1397, 2019)
    Ratka, Christoph
    Weigl, Paul
    Henrich, Dirk
    Koch, Felix
    Schlee, Markus
    Zipprich, Holger
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [43] Effects of air abrasive decontamination on titanium surfaces: A systematic review of in vitro studies
    Moharrami, Mohammad
    Perrotti, Vittoria
    Iaculli, Flavia
    Love, Robert M.
    Quaranta, Alessandro
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (02) : 398 - 421
  • [44] Scanning electron microscopy evaluation of enamel surfaces using different air-polishing powders in the orthodontic setting: an in vitro study
    Ratzka, Philipp
    Zaslansky, Paul
    Jost-Brinkmann, Paul-Georg
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2024, 85 (06): : 404 - 413
  • [45] IN-VITRO STUDY OF SOME CLEANING SOLUTIONS APPLIED ON DENTIN SURFACES
    SARACENI, CHC
    MATOS, AB
    CARVALHO, RCR
    MATSON, E
    PINTO, DS
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 798 - 798
  • [46] Comparison of Osseointegration on Various Implant Surfaces After Bacterial Contamination and Cleaning: A Rabbit Study
    Yuan, Kuo
    Chan, Ying-Jen
    Kung, Kuan-Chen
    Lee, Tzer-Min
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 32 - 40
  • [47] The Influence of Different Parameters of Magnetron Sputtering on the Structure and Chemical Composition of Titanium Alloy Implant Surfaces
    Zelensky, V., I
    Gevorgian, V. A.
    Tarala, V. A.
    Zelensky, V. A.
    Bobryshev, D., V
    Konovalov, E. A.
    Amkhadova, M. A.
    Gryzunov, S. A.
    Dolgalev, Al Al
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2019, 11 (04) : 120 - 124
  • [48] Increased reactivity and in vitro cell response of titanium based implant surfaces after anodic oxidation
    Walter, M. S.
    Frank, M. J.
    Sunding, M. F.
    Gomez-Florit, M.
    Monjo, M.
    Bucko, M. M.
    Pamula, E.
    Lyngstadaas, S. P.
    Haugen, H. J.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2013, 24 (12) : 2761 - 2773
  • [49] Increased reactivity and in vitro cell response of titanium based implant surfaces after anodic oxidation
    M. S. Walter
    M. J. Frank
    M. F. Sunding
    M. Gómez-Florit
    M. Monjo
    M. M. Bucko
    E. Pamula
    S. P. Lyngstadaas
    H. J. Haugen
    Journal of Materials Science: Materials in Medicine, 2013, 24 : 2761 - 2773
  • [50] Pilot study on the clinical and microbiological effect of subgingival glycine powder air polishing using a cannula-like jet
    Kargas, K.
    Tsalikis, L.
    Sakellari, D.
    Menexes, G.
    Konstantinidis, A.
    INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2015, 13 (03) : 161 - 169