Parameters That Improve Cleaning Efficiency of Subgingival Air Polishing on Titanium Implant Surfaces: An In Vitro Study

被引:13
|
作者
Tastepe, Ceylin S. [1 ]
Lin, Xingnan [1 ,2 ]
Donnet, Marcel [3 ]
Wismeijer, Daniel [1 ]
Liu, Yuelian [1 ]
机构
[1] Res Inst MOVE, Acad Ctr Dent Amsterdam, Dept Oral Funct & Restorat Dent, Sect Oral Implantol & Prosthodont, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Netherlands
[2] Nanjing Univ, Affiliated Stomatol Hosp, Med Sch, Dept Orthodont, Nanjing, Jiangsu, Peoples R China
[3] EMS Electro Med Syst SA, Res Grp Dent, Nyon, Switzerland
关键词
Air abrasion; dental; dental implants; dental instruments; peri-implantitis; plaque removal; titanium; RANDOMIZED CLINICAL-TRIAL; ANTIINFECTIVE MECHANICAL THERAPY; PERI-IMPLANTITIS; GLYCINE-POWDER; ABRASIVE DEVICE; PLAQUE REMOVAL; NONSURGICAL TREATMENT; PERIODONTAL POCKETS; CYNOMOLGUS MONKEYS; SURGICAL-TREATMENT;
D O I
10.1902/jop.2016.160270
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: This study aims to reveal how air polishing behaves on a titanium surface by evaluating the size and shape of the cleaned area and the influence of different device settings, probing depths, and cleaning movements. Methods: Forty-eight titanium sandblasted large-grit acidetched surface film-coated disks were treated with an air abrasive system using a subgingival plastic nozzle. Two subgingival models were used: open-ended (step 1) and defined-size (step 2). In step 1, the most effective parameters were investigated by 5-second static applications under different settings. In step 2, the best settings were used for dynamic application to test influence of different movements (up-down, slowly up, rotation). For both steps, powder and water consumption and total cleaned area were calculated. Results: Air pressure was the main factor with the strongest effect on cleaning. Increasing air pressure extended cleaning area. Other factors, such as nozzle depth and excessive powder flow amount, had weak influence. Cleaning effect reached deeper than the nozzle physically reached. Step 2 showed that there was no significant difference between different nozzle movements; however, cleaning efficiency decreased significantly without movement. Conclusions: For the most effective clinical use of air polishing, it should be applied with high pressure, deep insertion of nozzle, and enough water flow. Additionally, the nozzle has to be moved to get the best cleaning effect.
引用
收藏
页码:407 / 414
页数:8
相关论文
共 50 条
  • [21] Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces: In vitro study
    Annunziata, Marco
    Canullo, Luigi
    Donnarumma, Giovanna
    Caputo, Pina
    Nastri, Livia
    Guida, Luigi
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2016, 21 (01): : E118 - E121
  • [22] Antibacterial Effect of Functionalized Polymeric Nanoparticles on Titanium Surfaces Using an In Vitro Subgingival Biofilm Model
    Bueno, Jaime
    Virto, Leire
    Toledano-Osorio, Manuel
    Figuero, Elena
    Toledano, Manuel
    Medina-Castillo, Antonio L.
    Osorio, Raquel
    Sanz, Mariano
    Herrera, David
    POLYMERS, 2022, 14 (03)
  • [23] In vivo and in vitro biofilm formation on two different titanium implant surfaces
    Buergers, Ralf
    Gerlach, Till
    Hahnel, Sebastian
    Schwarz, Frank
    Handel, Gerhard
    Gosau, Martin
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 156 - 164
  • [24] Air polishing and CHX effects in addition to subgingival ultrasonic instrumentation on clinical periodontal parameters: A randomised clinical trial
    Caygur, Ayse
    JOURNAL OF CONTEMPORARY MEDICAL SCIENCES, 2020, 6 (06): : 282 - 284
  • [25] The efficacy of diode laser and subgingival air polishing with erythritol in treatment of periodontitis (clinical and microbiological study)
    Elmeligy, Sara M. A.
    Saleh, Wafaa
    Elewa, Gasser M.
    Abu El-Ezz, Hani Z.
    Mahmoud, Noha Mostafa
    Elmeadawy, Samah
    BMC ORAL HEALTH, 2024, 24 (01):
  • [26] Antimicrobial Effect and Cytocompatibility After Using Different Decontamination Methods on Titanium Implant Surfaces: An In Vitro Study
    Alonso-Espanol, Andrea
    Bravo, Enrique
    de Albornoz, Ana Carrillo
    Martinez, Maria
    Doll-Nikutta, Katharina
    Winkel, Andreas
    Stiesch, Meike
    Herrera, David
    Alonso, Bettina
    Sanz, Mariano
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [27] Electrochemical Treatment of Contaminated Titanium Surfaces in Vitro: An Approach for Implant Surface Decontamination
    Al-Hashedi, Ashwaq Ali
    Laurenti, Marco
    Abdallah, Mohamed-Nur
    Albuquerque, Rubens F., Jr.
    Tamimi, Faleh
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2016, 2 (09): : 1504 - 1518
  • [28] Pectin nanocoating of titanium implant surfaces - an experimental study in rabbits
    Gurzawska, Katarzyna
    Dirscherl, Kai
    Jorgensen, Bodil
    Berglundh, Tord
    Jorgensen, Niklas Rye
    Gotfredsen, Klaus
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (03) : 298 - 307
  • [29] An optimization study of polishing efficiency of blisk and its technological parameters
    Huai, Wenbo
    Lin, Xiaojun
    SCIENCE PROGRESS, 2020, 103 (03)
  • [30] An in vitro study of the treatment of implant surfaces with different instruments
    Mengel, R
    Buns, CE
    Mengel, C
    Flores-de-Jacoby, L
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (01) : 91 - 96