Cooling gradients and formation of gaseous microemboli with cardiopulmonary bypass: An echocardiographic study

被引:22
|
作者
Geissler, HJ [1 ]
Allen, SJ [1 ]
Mehlhorn, U [1 ]
Davis, KL [1 ]
deVivie, ER [1 ]
Kurusz, M [1 ]
Butler, BD [1 ]
机构
[1] UNIV TEXAS,SCH MED,DEPT ANESTHESIOL,HOUSTON,TX 77030
来源
ANNALS OF THORACIC SURGERY | 1997年 / 64卷 / 01期
关键词
D O I
10.1016/S0003-4975(97)82824-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Previous studies demonstrated gas emboli formation during rewarming from hypothermia on cardiopulmonary bypass when the temperature gradient exceeded a critical threshold. It also has been suggested that formation of arterial gas emboli may occur during cooling on cardiopulmonary bypass when cooled oxygenated blood exiting the heat exchanger is warmed on mixture with the patient's blood. The purpose of this study was to determine under what circumstances gas emboli formation would occur during cooling on cardiopulmonary bypass. Methods. Eight anesthetized mongrel dogs were placed on cardiopulmonary bypass using a roller pump, membrane oxygenator, and arterial line filter. For emboli detection, we positioned a transesophageal echocardiographic probe at the aortic arch distal to the aortic cannula and Doppler probes at the common carotid artery and the arterial line. Cooling gradients between normothermic blood and cooled arterial perfusate of 5 degrees, 10 degrees, 15 degrees, 20 degrees, and 0 degrees C (isothermal controls) were investigated. In addition to preestablished temperature gradients, we investigated the effect of rapid cooling (maximal flow through the heat exchanger at a water bath temperature of 4 degrees C) after the initiation of normothermic cardiopulmonary bypass. Results. Minimal gas emboli were detected at the aortic arch at gradients of 10 degrees C or greater. The incidence of emboli was related directly to the magnitude of the temperature gradient (p < 0.01). No emboli were detected at the carotid artery. During rapid cooling, no emboli were observed either at the aorta or at the carotid artery. Conclusions. Cooling gradients of 10 degrees C or greater may be associated with gas emboli formation, but they may be of limited clinical significance because no emboli were detected distal to the aortic arch. During the application of rapid cooling, no emboli formation was observed. (C) 1997 by The Society of Thoracic Surgeons.
引用
收藏
页码:100 / 104
页数:5
相关论文
共 50 条
  • [1] SOURCES OF GASEOUS MICROEMBOLI DURING CARDIOPULMONARY BYPASS
    HILL, AG
    GROOM, RC
    TEWKSBURY, L
    MUNOZ, R
    MARINO, JA
    LEFRAK, EA
    PROCEEDINGS OF THE AMERICAN ACADEMY OF CARDIOVASCULAR PERFUSION, VOL 9, 1988, 9 : 122 - 130
  • [2] Measurement of gaseous microemboli in the prime before the initiation of cardiopulmonary bypass
    Husebraten, Inger M.
    Fiane, Arnt E.
    Ringdal, Mari-Anne I. L.
    Thiara, Amrit P. S.
    PERFUSION-UK, 2018, 33 (01): : 30 - 35
  • [3] The Effect of Nitric Oxide Supplied to the Sweep Gas of the Oxygenator on the Formation of Gaseous Microemboli during Cardiopulmonary Bypass (Experimental Study)
    Marichev, A. O.
    Radovskiy, A. M.
    Osovskikh, V. V.
    Kozyrev, D. A.
    Chomakhashvili, I. G.
    Lomaev, A. A.
    Sorokina, A. K.
    Chinenkov, I. A.
    Vasilchenko, O. I.
    Avezov, D. A.
    Kalinin, M. O.
    Bautin, A. E.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2024, 177 (06) : 787 - 791
  • [4] Elimination of Gaseous Microemboli From Cardiopulmonary Bypass Using Hypobaric Oxygenation
    Gipson, Keith E.
    Rosinski, David J.
    Schonberger, Robert B.
    Kubera, Cathryn
    Mathew, Eapen S.
    Nichols, Frank
    Dyckman, William
    Courtin, Francois
    Sherburne, Bradford
    Bordey, Angelique F.
    Gross, Jeffrey B.
    ANNALS OF THORACIC SURGERY, 2014, 97 (03): : 879 - 887
  • [5] Generation, detection and prevention of gaseous microemboli during cardiopulmonary bypass procedure
    Lou, Song
    CARDIOLOGY, 2011, 120 : 103 - 103
  • [6] The influence of gaseous microemboli on various biomarkers after minimized cardiopulmonary bypass
    Stehouwer, Marco C.
    de Vroege, Roel
    Bruggemans, Eline F.
    Hofman, Frederik N.
    Molenaar, Meyke A.
    van Oeveren, Wim
    de Mol, Bastian A.
    Bruins, Peter
    PERFUSION-UK, 2020, 35 (03): : 202 - 208
  • [7] Generation, detection and prevention of gaseous microemboli during cardiopulmonary bypass procedure
    Lou, Song
    Ji, Bingyang
    Liu, Jinping
    Yu, Kun
    Long, Cun
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (11): : 1039 - 1051
  • [8] Clinical Real-Time Monitoring of Gaseous Microemboli in Pediatric Cardiopulmonary Bypass
    Wang, Shigang
    Woitas, Karl
    Clark, J. Brian
    Myers, John L.
    Undar, Akif
    ARTIFICIAL ORGANS, 2009, 33 (11) : 1026 - 1030
  • [9] CARDIOPULMONARY BYPASS IMPAIRS VASCULAR ENDOTHELIAL RELAXATION - EFFECTS OF GASEOUS MICROEMBOLI IN DOGS
    FEERICK, AE
    JOHNSTON, WE
    STEINSLAND, O
    LIN, C
    WANG, Y
    UCHIDA, T
    PROUGH, DS
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (03): : H1174 - H1182
  • [10] PLATELET MICROEMBOLI IN CARDIOPULMONARY BYPASS
    KOEPKE, JA
    JENEVEIN, EP
    TRANSFUSION, 1965, 5 (04) : 374 - &