The influence of gaseous microemboli on various biomarkers after minimized cardiopulmonary bypass

被引:5
|
作者
Stehouwer, Marco C. [1 ]
de Vroege, Roel [2 ]
Bruggemans, Eline F. [3 ]
Hofman, Frederik N. [4 ]
Molenaar, Meyke A. [5 ]
van Oeveren, Wim [6 ]
de Mol, Bastian A. [7 ]
Bruins, Peter [8 ]
机构
[1] St Antonius Hosp, Dept Extracorporeal Circulat, Koekoekslaan 1,POB 2500, NL-3430 EM Nieuwegein, Netherlands
[2] HAGA Hosp, Dept Extracorporeal Circulat, The Hague, Netherlands
[3] LUMC, Dept Cardiothorac Surg, Leiden, Netherlands
[4] St Antonius Hosp, Dept Cardiothorac Surg, Nieuwegein, Netherlands
[5] Jeroen Bosch Hosp, Dept Anaesthesiol, Den Bosch, Netherlands
[6] HaemoScan, Lab Blood Compatibil & Biomarker Detect, Groningen, Netherlands
[7] Eindhoven Univ Technol, Fac Biomed Technol, Sect Cardiovasc Biomech, Eindhoven, Netherlands
[8] St Antonius Hosp, Dept Anaesthesiol Intens Care & Pain Management, Nieuwegein, Netherlands
来源
PERFUSION-UK | 2020年 / 35卷 / 03期
关键词
gaseous microemboli; minimally invasive extracorporeal technology; minimized cardiopulmonary bypass; biomarkers; adverse effects cardiopulmonary bypass; EXTRACORPOREAL-CIRCULATION; CEREBRAL MICROEMBOLI; CLINICAL-EVALUATION; ENDOTHELIAL DAMAGE; OFF-PUMP; ARTERY; INFLAMMATION; SURGERY; PATHOPHYSIOLOGY; DYSFUNCTION;
D O I
10.1177/0267659119867572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Gaseous microemboli that originate from the cardiopulmonary bypass circuit may contribute to adverse outcome after cardiac surgery. We prospectively evaluated the influence of gaseous microemboli on the release of various biomarkers after use of a minimally invasive extracorporeal technology system. Methods: In 70 patients undergoing coronary artery bypass grafting with minimized cardiopulmonary bypass, gaseous microemboli were measured intraoperatively with a bubble counter. Intra- and postoperative biomarker levels for inflammatory response (interleukin-6, C5b-9), endothelial damage (von Willebrand factor, soluble vascular cell adhesion molecule-1), oxidative stress (malondialdehyde, 8-isoprostane, neuroketal), and neurological injury (neuron-specific enolase, brain-type fatty acid-binding protein) were analyzed using immune assay techniques. The relationship between gaseous microemboli number or volume and the incremental area under the curve (iAUC(24h)) or peak change for the biomarkers was calculated. Results: All biomarkers except for malondialdehyde increased at least temporarily after coronary artery bypass grafting with a minimally invasive extracorporeal technology system. The median total gaseous microemboli number was 6,174 (interquartile range: 3,507-10,531) and the median total gaseous microemboli volume was 4.31 mu L (interquartile range: 2.71-8.50). There were no significant correlations between total gaseous microemboli number or volume and iAUC(24h) or peak change for any of the biomarkers. After controlling for the variance of possible other predictor variables, multiple linear regression analysis showed no association between gaseous microemboli parameters and release of biomarkers. Conclusion: This study showed no evidence that gaseous microemboli contribute to increased biomarker levels after coronary artery bypass grafting with cardiopulmonary bypass. A reason for the absence of damage by gaseous microemboli may be the relative and considerably small amount of gaseous microemboli entering the patients in this study.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 50 条
  • [1] SOURCES OF GASEOUS MICROEMBOLI DURING CARDIOPULMONARY BYPASS
    HILL, AG
    GROOM, RC
    TEWKSBURY, L
    MUNOZ, R
    MARINO, JA
    LEFRAK, EA
    PROCEEDINGS OF THE AMERICAN ACADEMY OF CARDIOVASCULAR PERFUSION, VOL 9, 1988, 9 : 122 - 130
  • [2] Measurement of gaseous microemboli in the prime before the initiation of cardiopulmonary bypass
    Husebraten, Inger M.
    Fiane, Arnt E.
    Ringdal, Mari-Anne I. L.
    Thiara, Amrit P. S.
    PERFUSION-UK, 2018, 33 (01): : 30 - 35
  • [3] Elimination of Gaseous Microemboli From Cardiopulmonary Bypass Using Hypobaric Oxygenation
    Gipson, Keith E.
    Rosinski, David J.
    Schonberger, Robert B.
    Kubera, Cathryn
    Mathew, Eapen S.
    Nichols, Frank
    Dyckman, William
    Courtin, Francois
    Sherburne, Bradford
    Bordey, Angelique F.
    Gross, Jeffrey B.
    ANNALS OF THORACIC SURGERY, 2014, 97 (03): : 879 - 887
  • [4] Generation, detection and prevention of gaseous microemboli during cardiopulmonary bypass procedure
    Lou, Song
    CARDIOLOGY, 2011, 120 : 103 - 103
  • [5] Generation, detection and prevention of gaseous microemboli during cardiopulmonary bypass procedure
    Lou, Song
    Ji, Bingyang
    Liu, Jinping
    Yu, Kun
    Long, Cun
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (11): : 1039 - 1051
  • [6] Cooling gradients and formation of gaseous microemboli with cardiopulmonary bypass: An echocardiographic study
    Geissler, HJ
    Allen, SJ
    Mehlhorn, U
    Davis, KL
    deVivie, ER
    Kurusz, M
    Butler, BD
    ANNALS OF THORACIC SURGERY, 1997, 64 (01): : 100 - 104
  • [7] Clinical Real-Time Monitoring of Gaseous Microemboli in Pediatric Cardiopulmonary Bypass
    Wang, Shigang
    Woitas, Karl
    Clark, J. Brian
    Myers, John L.
    Undar, Akif
    ARTIFICIAL ORGANS, 2009, 33 (11) : 1026 - 1030
  • [8] CARDIOPULMONARY BYPASS IMPAIRS VASCULAR ENDOTHELIAL RELAXATION - EFFECTS OF GASEOUS MICROEMBOLI IN DOGS
    FEERICK, AE
    JOHNSTON, WE
    STEINSLAND, O
    LIN, C
    WANG, Y
    UCHIDA, T
    PROUGH, DS
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (03): : H1174 - H1182
  • [9] PLATELET MICROEMBOLI IN CARDIOPULMONARY BYPASS
    KOEPKE, JA
    JENEVEIN, EP
    TRANSFUSION, 1965, 5 (04) : 374 - &
  • [10] SIGNIFICANCE OF GASEOUS MICROEMBOLI IN THE CEREBRAL-CIRCULATION DURING CARDIOPULMONARY BYPASS IN DOGS
    JOHNSTON, WE
    STUMP, DA
    DEWITT, DS
    VINTENJOHANSEN, J
    OSTEEN, WK
    JAMES, RL
    PROUGH, DS
    CIRCULATION, 1993, 88 (05) : 319 - 329