Visualization of coronary artery calcium in dual energy chest radiography using automatic rib suppression

被引:3
|
作者
Zhou, Bo [1 ,2 ]
Jiang, Yi [2 ]
Wen, Di [1 ]
Gilkeson, Robert C. [3 ]
Hou, Jun [1 ]
Wilson, David L. [1 ,4 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Carnegie Mellon Univ, Robot Inst, Pittsburgh, PA 15213 USA
[3] Univ Hosp Cleveland, Med Ctr, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
来源
关键词
Dual energy chest radiography; Coronary artery calcification; Model-based segmentation; Rib suppression; registration; PHANTOM;
D O I
10.1117/12.2293007
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Coronary artery calcification (CAC) as assessed with CT calcium score is the best biomarker for predicting future cardiac events. Dual energy (DE) chest radiography offers an inexpensive, low radiation-dose alternative to CT. We have shown CAC can be visualized using non-gated, 2-shot, DE chest x-ray imaging. However, calcium signal from the ribs, superimposed on the CAC signal, can interfere with both image registration and reader detection of CAC. To improve the registration algorithm and the detectability of CAC, we created an enhanced CAC visualization algorithm with automatic rib segmentation and suppression. In this paper, we trained an active appearance model to detect the spatial location of rib in the DE bone images. Then, we suppressed the rib signal in the single kVp images using a kernel-filter based method. After the rib suppression, we used affine and non-rigid registration to align the CAC in low and high kVp image. 1800 dual energy cases were used in our experiment after data augmentation on 60 cases. We evaluated the segmentation from the rib AAM using six-fold cross validation. The average dice coefficient of the rib segmentation in the heart region is 0.92. The reduction of CAC mis-registration by the enhanced CAC registration algorithm is evaluated using both simulated and clinical images. Adding rib suppression improves the image registration significantly. Our results show that in both simulated synthetic images and clinical images, the CAC overlap improves from 0% to > 50% after rib suppression. Results suggest that CAC visualization and registration can be significantly improved using the rib suppression when rib signal confounds CAC signal in DE chest radiography.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Automatic detection and visualization system for coronary artery calcification using optical frequency domain imaging
    Oikawa, Ryo
    Doi, Akio
    Ishida, Masaru
    Chakraborty, Basabi
    ARTIFICIAL LIFE AND ROBOTICS, 2023, 28 (02) : 460 - 470
  • [42] Automatic detection and visualization system for coronary artery calcification using optical frequency domain imaging
    Ryo Oikawa
    Akio Doi
    Masaru Ishida
    Basabi Chakraborty
    Artificial Life and Robotics, 2023, 28 : 460 - 470
  • [43] CONVENTIONAL CHEST RADIOGRAPHY VS DUAL-ENERGY COMPUTED RADIOGRAPHY IN THE DETECTION AND CHARACTERIZATION OF PULMONARY NODULES
    KELCZ, F
    ZINK, FE
    PEPPLER, WW
    KRUGER, DG
    ERGUN, DL
    MISTRETTA, CA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (02) : 271 - 278
  • [44] Dual source computed tomography in visualization of coronary artery anomalies
    Opolski, Maksymilian P.
    Pregowski, Jerzy
    Kepka, Cezary
    Kruk, Mariusz
    Pracon, Radoslaw
    Ruzyllo, Witold
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2008, 4 (04): : 133 - 145
  • [45] An audit of follow-up chest radiography after coronary artery bypass graft
    Karthik, S.
    O'Regan, D. J.
    CLINICAL RADIOLOGY, 2006, 61 (07) : 616 - 618
  • [46] Rib suppression for enhancing frontal chest radiographs using independent component analysis
    Ahmed, Bilal
    Rasheed, Tahir
    Khan, Mohammed A. U.
    Cho, Seong Jin
    Lee, Sungyoung
    Kim, Tae-Seong
    ADAPTIVE AND NATURAL COMPUTING ALGORITHMS, PT 2, 2007, 4432 : 300 - +
  • [47] Effects of the technique parameters on the imaging performance of the dual-energy chest radiography
    Kim, Changsoo
    Yang, Sung-Hee
    Kim, Junwoo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (09) : 849 - 859
  • [48] Evaluation of a commercial cardiac motion phantom for dual-energy chest radiography
    Hsieh, Ching-Yi
    Gladish, Gregory
    Willis, Charles E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 235 - 251
  • [49] Optimization of a dual-energy imaging Kinestatic Charge Detector for chest radiography
    Schmithorst, Vincent J.
    Endorf, Robert J.
    Kulatunga, Sunil
    Spelic, David C.
    DiBianca, Frank A.
    Rodriguez, Carlos
    Zeman, Herbert D.
    Zhu, Zeping
    Giakos, George C.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (03) : 151 - 159
  • [50] Development of a non-linear dual-energy technique in chest radiography
    Lee, Minjae
    Lee, Donghoon
    Kim, Hyemi
    Choi, Sunghoon
    Kim, Dohyeon
    Kim, Hee-Joung
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172