Visualization of coronary artery calcium in dual energy chest radiography using automatic rib suppression

被引:3
|
作者
Zhou, Bo [1 ,2 ]
Jiang, Yi [2 ]
Wen, Di [1 ]
Gilkeson, Robert C. [3 ]
Hou, Jun [1 ]
Wilson, David L. [1 ,4 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Carnegie Mellon Univ, Robot Inst, Pittsburgh, PA 15213 USA
[3] Univ Hosp Cleveland, Med Ctr, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
来源
MEDICAL IMAGING 2018: IMAGE PROCESSING | 2018年 / 10574卷
关键词
Dual energy chest radiography; Coronary artery calcification; Model-based segmentation; Rib suppression; registration; PHANTOM;
D O I
10.1117/12.2293007
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Coronary artery calcification (CAC) as assessed with CT calcium score is the best biomarker for predicting future cardiac events. Dual energy (DE) chest radiography offers an inexpensive, low radiation-dose alternative to CT. We have shown CAC can be visualized using non-gated, 2-shot, DE chest x-ray imaging. However, calcium signal from the ribs, superimposed on the CAC signal, can interfere with both image registration and reader detection of CAC. To improve the registration algorithm and the detectability of CAC, we created an enhanced CAC visualization algorithm with automatic rib segmentation and suppression. In this paper, we trained an active appearance model to detect the spatial location of rib in the DE bone images. Then, we suppressed the rib signal in the single kVp images using a kernel-filter based method. After the rib suppression, we used affine and non-rigid registration to align the CAC in low and high kVp image. 1800 dual energy cases were used in our experiment after data augmentation on 60 cases. We evaluated the segmentation from the rib AAM using six-fold cross validation. The average dice coefficient of the rib segmentation in the heart region is 0.92. The reduction of CAC mis-registration by the enhanced CAC registration algorithm is evaluated using both simulated and clinical images. Adding rib suppression improves the image registration significantly. Our results show that in both simulated synthetic images and clinical images, the CAC overlap improves from 0% to > 50% after rib suppression. Results suggest that CAC visualization and registration can be significantly improved using the rib suppression when rib signal confounds CAC signal in DE chest radiography.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] DUAL-ENERGY CHEST RADIOGRAPHY - PHYSICAL PRINCIPLES AND CLINICAL POTENTIAL
    BARNES, GT
    FRASER, RG
    SANDERS, PC
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) : C389 - C389
  • [32] COMPARISON OF DUAL-ENERGY AND CONVENTIONAL CHEST RADIOGRAPHY FOR NODULE DETECTION
    HO, JT
    KRUGER, RA
    INVESTIGATIVE RADIOLOGY, 1989, 24 (11) : 861 - 868
  • [33] Aortic calcification on plain chest radiography increases risk for coronary artery disease
    Li, J
    Galvin, HK
    Johnson, SC
    Langston, CS
    Sclamberg, J
    Preston, CA
    CHEST, 2002, 121 (05) : 1468 - 1471
  • [34] Rib Locating on Chest Direct Radiography Image using Watershed Algorithm and Correlation Matching
    Li, Xuechen
    Luo, Suhuai
    Hu, Qingmao
    2013 INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL MODELS FOR LIFE SCIENCES, 2013, 1559 : 90 - 97
  • [35] Stationary Digital Chest Tomosynthesis for Coronary Artery Calcium Scoring
    Wu, Gongting
    Wang, Jiong
    Potzuko, Marci
    Harman, Allison
    Pearce, Caleb
    Shan, Jing
    Lee, Yueh Z.
    Zhou, Otto
    Lu, Jianping
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [36] Automated Coronary Artery Calcium Scoring for Chest CT Scans
    Vannier, Michael W.
    RADIOLOGY, 2020, 295 (01) : 80 - 81
  • [37] Coronary Artery Calcium as a Gatekeeper for Patients With Stable Chest Pain
    Winchester, David E.
    Al Rifai, Mahmoud
    JACC-CARDIOVASCULAR IMAGING, 2024, 17 (10) : 1211 - 1213
  • [38] An Update on Coronary Artery Calcium Interpretation at Chest and Cardiac CT
    Obisesan, Olufunmilayo H.
    Osei, Albert D.
    Uddin, S. M. Iftekhar
    Dzaye, Omar
    Blaha, Michael J.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (01):
  • [39] Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    Ide K.
    Mogami H.
    Murakami T.
    Yasuhara Y.
    Miyagawa M.
    Mochizuki T.
    Radiation Medicine, 2007, 25 (5): : 195 - 201
  • [40] LATERAL DUAL-ENERGY RADIOGRAPHY - ARTIFACT ERROR FROM RIB AND PELVIC BONE
    RUPICH, RC
    GRIFFIN, MG
    PACIFICI, R
    AVIOLI, LV
    SUSMAN, N
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 (01) : 97 - 101