X-band thermionic cathode RF gun and multi-beam Compton scattering monochromatic tunable X-ray source

被引:0
|
作者
Sakamoto, Fumito
Uesaka, Mitsuru
Dobashi, Katsuhiro
Fukasawa, Atsushi
Yamamoto, Tomohiko
Urakawa, Junji
Higo, Toshiyasu
Akemoto, Mitsuo
Matsuo, Kenichi
Sakae, Hisaharu
Yamamoto, Masashi
机构
[1] Univ Tokyo, Nucl Prof Sch, Naka, Ibaraki 3191188, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[3] Ishikawajima Harima Heavy Ind Co Ltd, Yokohama, Kanagawa 2358501, Japan
[4] Akita Natl Coll Technol, Akita 0118511, Japan
关键词
X-ray source; Compton scattering; X-band linac; X-band thermionic cathode RF gun;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A Compton scattering X-ray source consisting of an X-band (11.424 GHz) electron linear accelerator (linac) and Q-switched Nd:YAG laser is currently under construction. Monochromatic hard X-rays are required for a variety of medical and biological applications. The new hard X-ray source produces monochromatic X-rays via collision between a 35-MeV multi-bunch (10(4) bunches in a I mu s RF pulse) electron beam and 1.4 J/10 ns (532 nm) Nd:YAG laser beam. The linac uses an X-band 3.5-cell thermionic cathode RF gun and an alpha magnet as an injector. The thermionic cathode RF gun is the first of its kind and can generate a high current (2 mu A) and a multi-bunch 2-MeV electron beam. To increase the efficiency of the X-ray yield, a laser pulse circulation system is adopted, that can increase the X-ray intensity by up to 50 times. This scheme can produce monochromatic tunable X-rays (10 similar to 40 keV) with intensities of 10(8) similar to 10(9) photons/sec. In addition, the X-ray energy can be changed rapidly over 40 ms by two different wavelength lasers (YAG fundamental (1064 nm), 2nd harmonic (532 nm)) and an optical switch. This quick energy change is very important for living specimens and is very difficult to achieve in light sources such as a large SR (Synchrotron Radiation) source. The system can be used for dual-energy X-ray CT and subtraction X-ray CT to determine the 3D distribution of the atomic number density and electron density, and specified atomic distribution, respectively. In this paper, we describe the details of the system, report on experiments on the X-band thermionic cathode RF gun, and discuss applications of monochromatic X-rays.
引用
收藏
页码:286 / 297
页数:12
相关论文
共 50 条
  • [41] Monochromatic X-ray Source Based on Scattering from a Magnetic Nanoundulator
    Fisher, Sophie
    Roques-Carmes, Charles
    Rivera, Nicholas
    Wong, Liang Jie
    Kaminer, Ido
    Soljacic, Marin
    ACS PHOTONICS, 2020, 7 (05) : 1096 - 1103
  • [42] Development of a compact, tunable, laser-driven Compton scattering x-ray source for protein crystallography
    Hartemann, FV
    Gibson, DJ
    Brown, WJ
    Rupp, B
    Baldis, HA
    BIOMEDICAL NANOTECHNOLOGY ARCHITECTURES AND APPLICATIONS, 2002, 4626 : 276 - 288
  • [43] Characterization of the monochromatic laser Compton X-ray beam with picosecond and femtosecond pulse widths
    Endo, A
    Takasago, K
    Ito, S
    Yang, JF
    Yanagida, T
    Okada, Y
    Yorozu, M
    Sakai, F
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 100 - 108
  • [44] Tomosynthesis reconstruction from multi-beam X-ray sources
    Lalush, David S.
    Quan, Enzhuo
    Rajaram, Ramya
    Zhang, Jian
    Lu, Jianping
    Zhou, Otto
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1180 - +
  • [45] Compact Compton scattering X-ray source for advanced cancer research
    Luhmann, NC
    Boggan, JE
    Caryotakis, G
    Hartemann, FV
    Heritage, JP
    Landahl, E
    Matthews, DL
    Norman, A
    Solberg, T
    Vlieks, A
    2000 25TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES CONFERENCE DIGEST, 2000, : 7 - 8
  • [46] High duty cycle inverse Compton scattering X-ray source
    Ovodenko, A.
    Agustsson, R.
    Babzien, M.
    Campese, T.
    Fedurin, M.
    Murokh, A.
    Pogorelsky, I.
    Polyanskiy, M.
    Rosenzweig, J.
    Sakai, Y.
    Shaftan, T.
    Swinson, C.
    APPLIED PHYSICS LETTERS, 2016, 109 (25)
  • [47] USE OF CAPILLARY OPTICS AS A BEAM INTENSIFIER FOR A COMPTON X-RAY SOURCE
    TOMPKINS, PA
    ABREU, CC
    CARROLL, FE
    XIAO, QF
    MACDONALD, CA
    MEDICAL PHYSICS, 1994, 21 (11) : 1777 - 1784
  • [48] Optimization of a tunable quasi-monochromatic x-ray source for cell irradiations
    Neubert, W
    Enghardt, W
    Lehnert, U
    Müller, E
    Naumann, B
    Panteleeva, A
    Pawelke, J
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 123 - 128
  • [49] X-ray generation by inverse Compton scattering at the superconducting RF test facility
    Shimizu, Hirotaka
    Akemoto, Mitsuo
    Arai, Yasuo
    Araki, Sakae
    Aryshev, Alexander
    Fukuda, Masafumi
    Fukuda, Shigeki
    Haba, Junji
    Hara, Kazufumi
    Hayano, Hitoshi
    Higashi, Yasuo
    Honda, Yosuke
    Honma, Teruya
    Kako, Eiji
    Kojima, Yuji
    Kondo, Yoshinari
    Lekomtsev, Konstantin
    Matsumoto, Toshihiro
    Michizono, Shinichiro
    Miyoshi, Toshinobu
    Nakai, Hirotaka
    Nakajima, Hiromitsu
    Nakanishi, Kota
    Noguchi, Shuichi
    Okugi, Toshiyuki
    Sato, Masato
    Shevelev, Mikhail
    Shishido, Toshio
    Takenaka, Tateru
    Tsuchiya, Kiyosumi
    Urakawa, Junji
    Watanabe, Ken
    Yamaguchi, Seiya
    Yamamoto, Akira
    Yamamoto, Yasuchika
    Sakaue, Kazuyuki
    Hosoda, Seiichi
    Iijima, Hokuto
    Kuriki, Masao
    Tanaka, Ryuta
    Kuramoto, Ayaka
    Omet, Mathieu
    Takeda, Ayaki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 26 - 33
  • [50] Beam dynamics optimisation of an X-band Linac driven soft X-ray FEL
    Bartolini, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 657 (01): : 177 - 181