X-band thermionic cathode RF gun and multi-beam Compton scattering monochromatic tunable X-ray source

被引:0
|
作者
Sakamoto, Fumito
Uesaka, Mitsuru
Dobashi, Katsuhiro
Fukasawa, Atsushi
Yamamoto, Tomohiko
Urakawa, Junji
Higo, Toshiyasu
Akemoto, Mitsuo
Matsuo, Kenichi
Sakae, Hisaharu
Yamamoto, Masashi
机构
[1] Univ Tokyo, Nucl Prof Sch, Naka, Ibaraki 3191188, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[3] Ishikawajima Harima Heavy Ind Co Ltd, Yokohama, Kanagawa 2358501, Japan
[4] Akita Natl Coll Technol, Akita 0118511, Japan
关键词
X-ray source; Compton scattering; X-band linac; X-band thermionic cathode RF gun;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A Compton scattering X-ray source consisting of an X-band (11.424 GHz) electron linear accelerator (linac) and Q-switched Nd:YAG laser is currently under construction. Monochromatic hard X-rays are required for a variety of medical and biological applications. The new hard X-ray source produces monochromatic X-rays via collision between a 35-MeV multi-bunch (10(4) bunches in a I mu s RF pulse) electron beam and 1.4 J/10 ns (532 nm) Nd:YAG laser beam. The linac uses an X-band 3.5-cell thermionic cathode RF gun and an alpha magnet as an injector. The thermionic cathode RF gun is the first of its kind and can generate a high current (2 mu A) and a multi-bunch 2-MeV electron beam. To increase the efficiency of the X-ray yield, a laser pulse circulation system is adopted, that can increase the X-ray intensity by up to 50 times. This scheme can produce monochromatic tunable X-rays (10 similar to 40 keV) with intensities of 10(8) similar to 10(9) photons/sec. In addition, the X-ray energy can be changed rapidly over 40 ms by two different wavelength lasers (YAG fundamental (1064 nm), 2nd harmonic (532 nm)) and an optical switch. This quick energy change is very important for living specimens and is very difficult to achieve in light sources such as a large SR (Synchrotron Radiation) source. The system can be used for dual-energy X-ray CT and subtraction X-ray CT to determine the 3D distribution of the atomic number density and electron density, and specified atomic distribution, respectively. In this paper, we describe the details of the system, report on experiments on the X-band thermionic cathode RF gun, and discuss applications of monochromatic X-rays.
引用
收藏
页码:286 / 297
页数:12
相关论文
共 50 条
  • [31] Lattice design and beam dynamics in a compact X-ray source based on Compton scattering
    Yu, Peicheng
    Huang, Wenhui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 592 (1-2): : 1 - 8
  • [32] Quasi-monochromatic hard X-ray source via laser Compton scattering and its application
    Kuroda, R.
    Toyokawa, H.
    Yasumoto, M.
    Ikeura-Sekiguchi, H.
    Koike, M.
    Yamada, K.
    Yanagida, T.
    Nakajyo, T.
    Sakai, F.
    Mori, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 637 : S183 - S186
  • [33] Multi-beam multi-slice X-ray ptychography
    Astrand, Mattias
    Vogt, Ulrich
    Yang, Runqing
    Perez, Pablo Villanueva
    Li, Tang
    Lyubomirskiy, Mikhail
    Kahnt, Maik
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [34] Dual-energy X-ray CT by Compton scattering hard X-ray source
    Kaneyasu, T
    Uesaka, N
    Dobashi, K
    Torikoshi, M
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1680 - 1682
  • [35] Tunable monochromatic X-ray source based on parametric X-ray radiation at LEBRA, Nihon University
    Hayakawa, Y.
    Sato, I.
    Hayakawa, K.
    Tanaka, T.
    Kuwada, T.
    Sakai, T.
    Nogami, K.
    Nakao, K.
    Inagaki, M.
    Mori, A.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 123 - +
  • [36] X-ray source with quasi-monochromatic parallel beam
    Wang Rui-Rong
    An Hong-Hai
    Xiong Jun
    Xie Zhi-Yong
    Wang Wei
    ACTA PHYSICA SINICA, 2018, 67 (24)
  • [37] Source of X-ray radiation based on back compton scattering
    Bulyak, EV
    Gladkikh, PI
    Karnaukhov, IM
    Kononenko, SG
    Lapshin, VI
    Mytsykov, AO
    Telegin, YN
    Shcherbakov, AA
    Zelinsky, AY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (1-2): : 48 - 50
  • [38] Experimental study on an X-band coaxial multi-beam relativistic klystron amplifier
    Liu Zhen-Bang
    Jin Xiao
    Huang Hua
    Chen Huai-Bi
    Wang Gan-Ping
    ACTA PHYSICA SINICA, 2012, 61 (23)
  • [39] ERL-Based Laser-Compton Scattering X-Ray Source for X-Ray Imaging
    Kosuge, A.
    Akagi, T.
    Honda, Y.
    Araki, S.
    Urakawa, J.
    Terunuma, N.
    Nagai, R.
    Shizuma, T.
    Mori, M.
    Hajima, R.
    X-RAY LASERS 2016, 2018, 202 : 261 - 264
  • [40] Analysis and design of X-band coaxial multi-beam relativistic klystron amplifier
    Liu Zhen-Bang
    Jin Xiao
    Huang Hua
    Chen Huai-Bi
    ACTA PHYSICA SINICA, 2012, 61 (12)