Estimation of CO2 pipeline transport cost in South Korea based on the scenarios

被引:12
|
作者
Kang, Kwangu [1 ]
Huh, Cheol [1 ]
Kang, Seong-Gil [1 ]
Baek, Jong-Hwa [1 ]
Noh, Hyon Jeong [1 ]
机构
[1] Korea Res Inst Ships & Ocean Engn, Taejon 305343, South Korea
关键词
Offshore CCS; Pipeline transport; Transport cost; South Korea;
D O I
10.1016/j.egypro.2014.11.270
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
This study estimates the least cost CO2 pipeline specifications and corresponding transport costs for the offshore CCS in South Korea by using engineering-economic model. The major design factors are diameters and thicknesses of pipeline, number of boosters, and pressure conditions. First this study sets up three transport scenarios which are divided by the combination of three CO2 capture plants. The storage site is fixed Ulleung Basin whose storage capacity is estimated to around 5 GtCO(2). The capture rates of CO2 at each plants are assumed to be 1 MtCO(2)/y similar to 3 MtCO(2)/y. We calculate the pressure losses, number of boosters, thicknesses of pipeline and corresponding pipeline costs for eight diameters of pipeline in the range of 6 inch to 20 inch in 2 inch steps to comply with the standard pipe size. The pipeline diameter that shows minimum cost is selected as an optimum pipeline diameter. Scenario 1 has only one capture site, Boryeong Thermal Power Plant. The onshore and offshore transport route lengths are 470 km and 60 km, respectively. The optimum pipeline diameters at the transport rate of 1 MtCO(2)/y and 3 MtCO(2)/y are 8 inch and 14 inch, respectively. The required number of boosters at the transport rate of 1 MtCO(2)/y and 3 MtCO(2)/y are 2 and 1, respectively. The estimated transport costs at the transport rate of 1 MtCO(2)/y and 3 MtCO(2)/y are $23 and $11, respectively. The scale up effect significantly reduces the transport cost at 3 MtCO(2)/y compared to 1 MtCO(2)/y. Scenario 2 has same transport route with Scenario 1, but has additional capture plant at Hadong in the midway of route. The cost per unit CO2 of Scenario 2 is lower than Scenario 1 due to the scale up effect. Scenario 3 has two capture plants, one is Boryeong Power Plant and the other is Samcheok Power Plant. Unlike Scenario 2, the transport route is not overlapped except the offshore route. The CO2 transported from two power plants get together at Ulsan Harbor and are transported to offshore pipeline. Because of non-overlapping two transport routes in onshore section, the overall cost is comparable to Scenario 1. (C) 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC B Y-NC- ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
引用
收藏
页码:2475 / 2480
页数:6
相关论文
共 50 条
  • [41] CO2 reduction costs and benefits in transport: socio-technical scenarios
    Heikki Liimatainen
    Markus Pöllänen
    Riku Viri
    European Journal of Futures Research, 2018, 6
  • [42] CO2 reduction costs and benefits in transport: socio-technical scenarios
    Liimatainen, Heikki
    Pollanen, Markus
    Viri, Riku
    EUROPEAN JOURNAL OF FUTURES RESEARCH, 2018, 6 (01)
  • [43] The Possibility of CO2 Pipeline Transport for Enhanced Oil Recovery Project in Poland
    Wojnarowski, Pawel
    Czarnota, Robert
    Wlodek, Tomasz
    Janiga, Damian
    Stopa, Jerzy
    Kosowski, Piotr
    2018 6TH INTERNATIONAL CONFERENCE ON TRAFFIC AND LOGISTIC ENGINEERING (ICTLE 2018), 2019, 259
  • [44] Heat Transfer Characteristics of a Pipeline for CO2 Transport with Water as Surrounding Substance
    Drescher, Michael
    Wilhelmsen, Oivind
    Aursand, Peder
    Aursand, Eskil
    de Koeijer, Gelein
    Held, Rudolf
    GHGT-11, 2013, 37 : 3047 - 3056
  • [45] Effect of Water and Nitrogen Impurities on CO2 Pipeline Transport for Geological Storage
    Huh, Cheol
    Kang, Seong-Gil
    Cho, Mang-Ik
    Baek, Jong-Hwa
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 2214 - 2221
  • [46] Potential economies of scale in CO2 transport through use of a trunk pipeline
    Chandel, Munish Kumar
    Pratson, Lincoln F.
    Williams, Eric
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2825 - 2834
  • [47] CO2 emission from the rail and road transport using input-output analysis: An application to South Korea
    Lee, C.-K. (cheul@krri.re.kr), 1600, Korean Society of Environmental Engineers (17):
  • [48] Optimal design and cost of ship-based CO2 transport under uncertainties and fluctuations
    Bjerketvedt, Vegard Skonseng
    Tomasgard, Asgeir
    Roussanaly, Simon
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2020, 103 (103)
  • [49] Risks and Safety of CO2 Pipeline Transport: A Case Study of the Analysis and Modeling of the Risk of Accidental Release of CO2 into the Atmosphere
    Bielka, Pawel
    Kuczynski, Szymon
    Wlodek, Tomasz
    Nagy, Stanislaw
    ENERGIES, 2024, 17 (16)
  • [50] Energy and CO2 Flow Networks of the Electronics Industry Sector in South Korea
    Kim, Junbeum
    Allenby, Brad
    2009 IEEE INTERNATIONAL SYMPOSIUM ON SUSTAINABLE SYSTEMS AND TECHNOLOGY, 2009, : 418 - 418