Estimation of CO2 pipeline transport cost in South Korea based on the scenarios

被引:12
|
作者
Kang, Kwangu [1 ]
Huh, Cheol [1 ]
Kang, Seong-Gil [1 ]
Baek, Jong-Hwa [1 ]
Noh, Hyon Jeong [1 ]
机构
[1] Korea Res Inst Ships & Ocean Engn, Taejon 305343, South Korea
关键词
Offshore CCS; Pipeline transport; Transport cost; South Korea;
D O I
10.1016/j.egypro.2014.11.270
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
This study estimates the least cost CO2 pipeline specifications and corresponding transport costs for the offshore CCS in South Korea by using engineering-economic model. The major design factors are diameters and thicknesses of pipeline, number of boosters, and pressure conditions. First this study sets up three transport scenarios which are divided by the combination of three CO2 capture plants. The storage site is fixed Ulleung Basin whose storage capacity is estimated to around 5 GtCO(2). The capture rates of CO2 at each plants are assumed to be 1 MtCO(2)/y similar to 3 MtCO(2)/y. We calculate the pressure losses, number of boosters, thicknesses of pipeline and corresponding pipeline costs for eight diameters of pipeline in the range of 6 inch to 20 inch in 2 inch steps to comply with the standard pipe size. The pipeline diameter that shows minimum cost is selected as an optimum pipeline diameter. Scenario 1 has only one capture site, Boryeong Thermal Power Plant. The onshore and offshore transport route lengths are 470 km and 60 km, respectively. The optimum pipeline diameters at the transport rate of 1 MtCO(2)/y and 3 MtCO(2)/y are 8 inch and 14 inch, respectively. The required number of boosters at the transport rate of 1 MtCO(2)/y and 3 MtCO(2)/y are 2 and 1, respectively. The estimated transport costs at the transport rate of 1 MtCO(2)/y and 3 MtCO(2)/y are $23 and $11, respectively. The scale up effect significantly reduces the transport cost at 3 MtCO(2)/y compared to 1 MtCO(2)/y. Scenario 2 has same transport route with Scenario 1, but has additional capture plant at Hadong in the midway of route. The cost per unit CO2 of Scenario 2 is lower than Scenario 1 due to the scale up effect. Scenario 3 has two capture plants, one is Boryeong Power Plant and the other is Samcheok Power Plant. Unlike Scenario 2, the transport route is not overlapped except the offshore route. The CO2 transported from two power plants get together at Ulsan Harbor and are transported to offshore pipeline. Because of non-overlapping two transport routes in onshore section, the overall cost is comparable to Scenario 1. (C) 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC B Y-NC- ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
引用
收藏
页码:2475 / 2480
页数:6
相关论文
共 50 条
  • [31] CO2 pipeline to Canada
    不详
    PIPELINE & GAS JOURNAL, 1997, 224 (08) : 6 - 6
  • [32] Regionalized global energy scenarios meeting stringent CO2 constraints -: Cost-effective fuel choices for transport
    Grahn, M
    Azar, C
    Lindgren, K
    ENERGY & ENVIRONMENT - A WORLD OF CHALLENGES AND OPPORTUNITIES, PROCEEDINGS, 2003, : 33 - 37
  • [33] Economic Analysis on Hydrogen Pipeline Infrastructure Establishment Scenarios: Case Study of South Korea
    Lee, Heeyeon
    Lee, Sanghun
    ENERGIES, 2022, 15 (18)
  • [34] Characterizing the spatial distribution of CO2 leakage from the shallow CO2 release experiment in South Korea
    Kim, Hyun-Jun
    Han, Seung Hyun
    Kim, Seongjun
    Yun, Seong-Taek
    Jun, Seong-Chun
    Oh, Yun-Yeong
    Son, Yowhan
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 72 : 152 - 162
  • [35] Large-scale CO2 transport and storage infrastructure development and cost estimation in the Netherlands offshore
    Wildenborg, Ton
    Loeve, Daniel
    Neele, Filip
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2022, 118
  • [36] Prediction Model of CO2 Emission for Residential Buildings in South Korea
    Moon, HyunSeok
    Hyun, ChangTaek
    Hong, TaeHoon
    JOURNAL OF MANAGEMENT IN ENGINEERING, 2014, 30 (03)
  • [37] Steady-state design of CO2 pipeline networks for minimal cost per tonne of CO2 avoided
    Weihs, G. A. Fimbres
    Wiley, D. E.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 8 : 150 - 168
  • [38] The assessment of renewable energy planning on CO2 abatement in South Korea
    Jun, Sooyoung
    Lee, Seungmoon
    Park, Jin-Won
    Jeong, Suk-Jae
    Shin, Ho-Chul
    RENEWABLE ENERGY, 2010, 35 (02) : 471 - 477
  • [39] ENERGY AND CO2 EMISSIONS IN KOREA - LONG-TERM SCENARIOS AND RELATED POLICIES
    LEE, HS
    RYU, JC
    ENERGY POLICY, 1991, 19 (10) : 926 - 933
  • [40] The cost of CO2 transport by truck and rail in the United States
    Myers, Corey
    Li, Wenqin
    Markham, Gregory
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2024, 134