Accuracy and precision of in vitro volumetric measurements by three-dimensional sonography

被引:13
|
作者
Wong, J
Gerscovich, EO
Cronan, MS
Seibert, JA
机构
[1] UNIV CALIF DAVIS,MED CTR,DEPT RADIOL,SACRAMENTO,CA 95817
[2] CALIF STATE UNIV SACRAMENTO,SACRAMENTO DEPT BIOMED ENGN,SACRAMENTO,CA
关键词
ultrasonic diagnosis; three-dimensional ultrasound; instrument accuracy; volume estimation;
D O I
10.1097/00004424-199601000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. A radiologist often wishes to measure organ volume or monitor changes in internal lesion volume during treatment. If this can be determined via three-dimensional ultrasound, the relative simplicity of the procedure and the decreased cost and known risks to the patient would make this method an attractive alternative to other modalities. METHODS. Three-dimensional ultrasound scans were made of six phantoms: four nonechogenic spheres, one echogenic sphere, and one echogenic, irregularly shaped phantom. A total of 22 volume scans were produced. Volume estimations were made using data from cross-sectional areas and from linear measurements. In all, 193 volume estimations were made. These results were compared with known volumes and with volume estimates from computed tomography scans. RESULTS. Three-dimensional ultrasound detected size differences of 10% with 95% certainty. CONCLUSIONS. The accuracy and precision of volume estimates via three-dimensional ultrasound is at least as good as those obtained via conventional ultrasound.
引用
下载
收藏
页码:26 / 29
页数:4
相关论文
共 50 条
  • [41] Two-dimensional and three-dimensional sonography of conjoined twins
    Bonilla-Musoles, F
    Machado, LE
    Osborne, NG
    Blanes, J
    Bonilla, F
    Raga, F
    Machado, F
    JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (02) : 68 - 75
  • [42] Three-dimensional hysterosonographic evaluation of the normal endometrium: Comparison with transvaginal sonography and three-dimensional ultrasound
    BonillaMusoles, F
    Raga, F
    Blanes, J
    Osborne, NG
    Coelho, F
    JOURNAL OF GYNECOLOGIC SURGERY, 1997, 13 (03) : 101 - 107
  • [43] Are Three-Dimensional Volumetric Measurements of Brain Metastasis the Future for Disease Control? A Comparative Study
    Fischedick, G.
    Haverkamp, U.
    Fischedick, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E659 - E660
  • [44] Feasibility of a new generation three-dimensional echocardiography for right ventricular volumetric and functional measurements
    Tamborini, Gloria
    Brusoni, Denise
    Molina, Jorge Eduardo Torres
    Galli, Claudia Agnese
    Maltagliati, Anna
    Muratori, Manuela
    Susini, Francesca
    Colombo, Chiara
    Maffessanti, Francesco
    Pepi, Mauro
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (04): : 499 - 505
  • [45] Dimensional accuracy achievable by three-dimensional printing
    Islam, M. N.
    Boswell, B.
    Pramanik, A.
    IAENG TRANSACTIONS ON ENGINEERING SCIENCES, 2014, : 263 - 268
  • [46] Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle
    Elrawdy, Ahmed M.
    Amer, Mohamed E.
    Algariah, Ahmed K.
    Eid, Mohamed H.
    Abu-Elsaoud, Abdelghafar M.
    Ghoneim, Mohamed M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [47] Three-dimensional bioprinting of volumetric tissues and organs
    David Kilian
    Tilman Ahlfeld
    Ashwini Rahul Akkineni
    Anja Lode
    Michael Gelinsky
    MRS Bulletin, 2017, 42 : 585 - 592
  • [48] Volumetric techniques: three-dimensional midface modeling
    Macierzynska, Arleta
    Pierzchala, Ewa
    Placek, Waldemar
    POSTEPY DERMATOLOGII I ALERGOLOGII, 2014, 31 (06): : 388 - 391
  • [49] Three-dimensional wavelet coding of volumetric imagery
    Vass, J.
    Palaniappan, K.
    Zhuang, X.
    International Journal of Robotics and Automation, 2000, 15 (01) : 34 - 47
  • [50] Novel volumetric three-dimensional display system
    College of Automation Engineering, NUAA, 29 Yudao Street, Nanjing 210016, China
    Trans. Nanjing Univ. Aero. Astro., 2008, 1 (32-36):