共 50 条
Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle
被引:0
|作者:
Elrawdy, Ahmed M.
[1
]
Amer, Mohamed E.
[2
]
Algariah, Ahmed K.
[3
]
Eid, Mohamed H.
[4
,5
]
Abu-Elsaoud, Abdelghafar M.
[6
]
Ghoneim, Mohamed M.
[7
]
机构:
[1] Suez Canal Univ, Fac Dent, Dept Oral Radiol, Ismailia, Egypt
[2] Zagazig Univ, Fac Dent, Dept Orthodont, Zagazig, Egypt
[3] Sinai Univ, Fac Dent, Dept Orthodont, Ismailia, Egypt
[4] Suez Canal Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Ismailia, Egypt
[5] Imam Mohammad Ibn Saud Islamic Univ, Coll Sci, Dept Biol, Riyadh, Saudi Arabia
[6] Suez Canal Univ, Fac Sci, Ismailia, Egypt
[7] Sinai Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Al Arish, Egypt
关键词:
human condyle;
pycnometer;
condyle;
3d printing;
volumetric measures;
IMAGES;
D O I:
10.7759/cureus.46746
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background This study aims to evaluate the accuracy of volumetric measurements of three-dimensional (3D)-printed human condyles from cone-beam computed tomography (CBCT) in comparison to physical condyles using a water displacement test.Methodology A sample of 22 dry condyles was separated from the mandibular body by disc, mounted on a base made of casting wax, and scanned using the SCANORA (Scanora 3DX, Soredex, Finland) CBCT scanner. Subsequently, the projection data were reconstructed with the machine-dedicated OnDemand 3D (Cybermed Co., Seoul, Korea). The Standard Tessellation Language file was prepared for 3D printing using chitubox slicing software v1.9.1. Frozen water-washable gray resin was used for 3D printing. All condyles were printed using the same parameters and the same resin. The volumetric measurements were then performed using a customized modified pycnometer based on water volume and weight displacement. Volumetric measures were performed for both the physical human condyles and the 3D-printed replicas and the measurements were then compared.Results The volume of dry condyles using the water displacement method showed an average (+/- SD) of 1.925 +/- 0.40 cm(3). However, the volume of 3D-printed replicas using the water displacement method showed an average (+/- SD) of 2.109 +/- 0.40 cm(3). The differences in measurements were insignificant (p > 0.05), as revealed by an independent t-test.Conclusions Highly precise, accurate, and reliable CBCT for volumetric mandibular condyle was applied for measurements of a human condyle and 3D-printed replica. The modified pycnometer for volumetric measurements presented an excellent volumetric measure based on a simple water displacement device. The tested modified pycnometer can be applied in volumetric measurements in both 3D-printed and mandibular condyle. For best accuracy, the highest scanning resolution possible should be used. As it directly handles irregularly shaped solid objects in a non-destructive manner with a high level of precision and reliability, this 3D scanning approach may be seen as a superior alternative to the current measurement methods.
引用
下载
收藏
页数:16
相关论文