Appraisal of the Accuracy and Reliability of Cone-Beam Computed Tomography and Three-Dimensional Printing for Volumetric Mandibular Condyle Measurements of a Human Condyle

被引:0
|
作者
Elrawdy, Ahmed M. [1 ]
Amer, Mohamed E. [2 ]
Algariah, Ahmed K. [3 ]
Eid, Mohamed H. [4 ,5 ]
Abu-Elsaoud, Abdelghafar M. [6 ]
Ghoneim, Mohamed M. [7 ]
机构
[1] Suez Canal Univ, Fac Dent, Dept Oral Radiol, Ismailia, Egypt
[2] Zagazig Univ, Fac Dent, Dept Orthodont, Zagazig, Egypt
[3] Sinai Univ, Fac Dent, Dept Orthodont, Ismailia, Egypt
[4] Suez Canal Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Ismailia, Egypt
[5] Imam Mohammad Ibn Saud Islamic Univ, Coll Sci, Dept Biol, Riyadh, Saudi Arabia
[6] Suez Canal Univ, Fac Sci, Ismailia, Egypt
[7] Sinai Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Al Arish, Egypt
关键词
human condyle; pycnometer; condyle; 3d printing; volumetric measures; IMAGES;
D O I
10.7759/cureus.46746
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This study aims to evaluate the accuracy of volumetric measurements of three-dimensional (3D)-printed human condyles from cone-beam computed tomography (CBCT) in comparison to physical condyles using a water displacement test.Methodology A sample of 22 dry condyles was separated from the mandibular body by disc, mounted on a base made of casting wax, and scanned using the SCANORA (Scanora 3DX, Soredex, Finland) CBCT scanner. Subsequently, the projection data were reconstructed with the machine-dedicated OnDemand 3D (Cybermed Co., Seoul, Korea). The Standard Tessellation Language file was prepared for 3D printing using chitubox slicing software v1.9.1. Frozen water-washable gray resin was used for 3D printing. All condyles were printed using the same parameters and the same resin. The volumetric measurements were then performed using a customized modified pycnometer based on water volume and weight displacement. Volumetric measures were performed for both the physical human condyles and the 3D-printed replicas and the measurements were then compared.Results The volume of dry condyles using the water displacement method showed an average (+/- SD) of 1.925 +/- 0.40 cm(3). However, the volume of 3D-printed replicas using the water displacement method showed an average (+/- SD) of 2.109 +/- 0.40 cm(3). The differences in measurements were insignificant (p > 0.05), as revealed by an independent t-test.Conclusions Highly precise, accurate, and reliable CBCT for volumetric mandibular condyle was applied for measurements of a human condyle and 3D-printed replica. The modified pycnometer for volumetric measurements presented an excellent volumetric measure based on a simple water displacement device. The tested modified pycnometer can be applied in volumetric measurements in both 3D-printed and mandibular condyle. For best accuracy, the highest scanning resolution possible should be used. As it directly handles irregularly shaped solid objects in a non-destructive manner with a high level of precision and reliability, this 3D scanning approach may be seen as a superior alternative to the current measurement methods.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography
    Bastos, Luana Costa
    Flores Campos, Paulo Sergio
    de Moraes Ramos-Perez, Flavia Maria
    Pontual, Andrea dos Anjos
    Almeida, Solange Maria
    BRAZILIAN ORAL RESEARCH, 2013, 27 (06) : 503 - 509
  • [32] Accuracy of three dimensional cone beam computed tomography printed images in assessment of mandibular linear measurements
    Ahmed, Walaa Abd El Aty
    Abd El Kader, Hoda Saleh
    Dakhli, Iman Ismail
    Abdelrahim, Dina Fahim
    BIOSCIENCE RESEARCH, 2018, 15 (04): : 4196 - 4202
  • [33] Trabecular structural changes in the mandibular condyle caused by degenerative osteoarthritis: a comparative study by cone-beam computed tomography imaging
    Saadettin Kayipmaz
    Saliha Akçay
    Ömer Said Sezgin
    Celal Çandirli
    Oral Radiology, 2019, 35 : 51 - 58
  • [34] Accuracy of Software-Based Three-Dimensional Root Canal Length Measurements Using Cone-Beam Computed Tomography
    Tchorz, J. P.
    Wrbas, K. T.
    Von See, C.
    Vach, K.
    Patzelt, S. B. M.
    EUROPEAN ENDODONTIC JOURNAL, 2019, 4 (01): : 28 - 32
  • [35] The Three-Dimensional Evaluation of Radicular Cyst by Cone-Beam Computed Tomography
    Viggness, Arun
    Priyaa, Sasti
    Thangavelu, Ravikumar Pethagounder
    Fenn, Saramma Mathew
    Mohan, Karthik Rajaram
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [36] Assessment of Radiodensity at Mandibular Periapical Bone Sites using Three-Dimensional Cone-Beam Computed Tomography
    Goyushov, Samir
    Asar, Neset Volkan
    Tozum, Tolga Fikret
    JOMR-JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, 2023, 14 (01):
  • [37] Three-dimensional morphological characterization of malocclusions with mandibular lateral displacement using cone-beam computed tomography
    Velasquez, Roberto L.
    Coro, Jorge C.
    Londono, Alejandra
    McGorray, Susan R.
    Wheeler, Timothy T.
    Sato, Sadao
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2018, 36 (03): : 143 - 155
  • [38] The three-dimensional cancellous bone architecture of the human mandibular condyle
    Giesen, EBW
    van Eijden, TMGJ
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (04) : 957 - 963
  • [39] Three-dimensional localization of maxillary canines with cone-beam computed tomography
    Walker, L
    Enciso, R
    Mah, J
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (04) : 418 - 423
  • [40] Correlation of Panoramic Radiography, Cone-Beam Computed Tomography, and Three-Dimensional Printing in the Assessment of the Spatial Location of Impacted Mandibular Third Molars
    Jaron, Aleksandra
    Gabrysz-Trybek, Ewa
    Bladowska, Joanna
    Trybek, Grzegorz
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)