Cardiac Motion Correction for Helical CT Scan With an Ordinary Pitch

被引:13
|
作者
Kim, Seungeon [1 ]
Chang, Yongjin [1 ]
Ra, Jong Beom [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon 34141, South Korea
关键词
Cardiac motion estimation and compensation; cardiac X-ray computed tomography (CT); coronary artery imaging; helical CT scan; partial angle reconstruction; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONE-BEAM RECONSTRUCTION; FRACTIONAL FLOW RESERVE; CORONARY-ARTERY MOTION; MULTISLICE SPIRAL CT; IMAGE-RECONSTRUCTION; FBP ALGORITHM; REGISTRATION; COMPENSATION; RESOLUTION;
D O I
10.1109/TMI.2018.2817594
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cardiac X-ray computed tomography (CT) imaging is still challenging due to the cardiac motion during CT scanning, which leads to the presence of motion artifacts in the reconstructed image. In response, many cardiac X-ray CT imaging algorithms have been proposed, based on motion estimation (ME) and motion compensation (MC), to improve the image quality by alleviating the motion artifacts in the reconstructed image. However, these ME/MC algorithms are mainly based on an axial scan or a low-pitch helical scan. In this paper, we propose a ME/MC-based cardiac imaging algorithm for the data set acquired from a helical scan with an ordinary pitch of around 1.0 so as to obtain the whole cardiac image within a single scan of short time without ECG gating. In the proposed algorithm, a sequence of partial angle reconstructed (PAR) images is generated by using consecutive parts of the sinogram, each of which has a small angular span. Subsequently, an initial 4-D motion vector field (MVF) is obtained using multiple pairs of conjugate PAR images. The 4-D MVF is then refined based on an image quality metric so as to improve the quality of the motion-compensated image. Finally, a time-resolved cardiac image is obtained by performing motion-compensated image reconstruction by using the refined 4-DMVF. Using digital XCAT phantom data sets and a human data set commonly obtained via a helical scan with a pitch of 1.0, we demonstrate that the proposed algorithm significantly improves the image quality by alleviating motion artifacts.
引用
收藏
页码:1587 / 1596
页数:10
相关论文
共 50 条
  • [41] Motion correction in PET/CT
    Schäfers, KP
    Dawood, M
    Lang, N
    Büther, F
    Schäfers, M
    Schober, O
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2005, 44 : S46 - S50
  • [42] High-dose helical CT of the liver with computer-automated scan technology: Comparison with helical CT arterial portography and conventional helical CT
    Choi, CS
    Freeny, PC
    Heyano, S
    RADIOLOGY, 1996, 201 : 90 - 90
  • [43] Can a single CT scan be used for both stress and rest attenuation correction in cardiac SPECT?
    Bai, Chuanyong
    Conwell, Richard
    Old, Rex
    Maddahi, Jamshid
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [44] A method to correct for rigid motion in helical CT
    Kim, Jung-Ha
    Nuyts, Johan
    Kuncic, Zdenka
    Fulton, Roger
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [45] A method to correct for rigid motion in helical CT
    Kim, Jung-Ha
    Nuyts, Johan
    Kuncic, Zdenka
    Fulton, Roger
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [46] Single-Phase CT Aligned to Gated PET for Respiratory Motion Correction in Cardiac PET/CT
    Wells, R. Glenn
    Ruddy, Terrence D.
    DeKemp, Rob A.
    DaSilva, Jean N.
    Beanlands, Rob S.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) : 1182 - 1190
  • [47] Investigation of Respiratory Motion Correction with and without Motion Correction of Attenuation Map in Cardiac SPECT/CT in Presence of Non-Rigid Motion, an NCAT study
    Dey, Joyoni
    Segars, W. P.
    Pretorius, P. Hendrik
    King, Michael A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3237 - 3243
  • [48] Evaluation of helical tomotherapy megavoltage CT system for daily automatic patient setup correction and manual prostate gland motion correction
    Han, C.
    Schultheiss, T.
    Liu, A.
    Wong, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1988 - 1988
  • [49] APPROXIMATE EQUATIONS OF MOTION FOR ELASTIC RINGS AND HELICAL COILS OF SMALL PITCH
    HAINES, DW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (01): : 127 - &
  • [50] The effect of helical pitch and beam collimation on the lesion contrast and slice profile in helical CT imaging
    Hu, H
    Fox, SH
    MEDICAL PHYSICS, 1996, 23 (12) : 1943 - 1954