Cardiac Motion Correction for Helical CT Scan With an Ordinary Pitch

被引:13
|
作者
Kim, Seungeon [1 ]
Chang, Yongjin [1 ]
Ra, Jong Beom [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon 34141, South Korea
关键词
Cardiac motion estimation and compensation; cardiac X-ray computed tomography (CT); coronary artery imaging; helical CT scan; partial angle reconstruction; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONE-BEAM RECONSTRUCTION; FRACTIONAL FLOW RESERVE; CORONARY-ARTERY MOTION; MULTISLICE SPIRAL CT; IMAGE-RECONSTRUCTION; FBP ALGORITHM; REGISTRATION; COMPENSATION; RESOLUTION;
D O I
10.1109/TMI.2018.2817594
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cardiac X-ray computed tomography (CT) imaging is still challenging due to the cardiac motion during CT scanning, which leads to the presence of motion artifacts in the reconstructed image. In response, many cardiac X-ray CT imaging algorithms have been proposed, based on motion estimation (ME) and motion compensation (MC), to improve the image quality by alleviating the motion artifacts in the reconstructed image. However, these ME/MC algorithms are mainly based on an axial scan or a low-pitch helical scan. In this paper, we propose a ME/MC-based cardiac imaging algorithm for the data set acquired from a helical scan with an ordinary pitch of around 1.0 so as to obtain the whole cardiac image within a single scan of short time without ECG gating. In the proposed algorithm, a sequence of partial angle reconstructed (PAR) images is generated by using consecutive parts of the sinogram, each of which has a small angular span. Subsequently, an initial 4-D motion vector field (MVF) is obtained using multiple pairs of conjugate PAR images. The 4-D MVF is then refined based on an image quality metric so as to improve the quality of the motion-compensated image. Finally, a time-resolved cardiac image is obtained by performing motion-compensated image reconstruction by using the refined 4-DMVF. Using digital XCAT phantom data sets and a human data set commonly obtained via a helical scan with a pitch of 1.0, we demonstrate that the proposed algorithm significantly improves the image quality by alleviating motion artifacts.
引用
收藏
页码:1587 / 1596
页数:10
相关论文
共 50 条
  • [21] Optimization of helical CT angiography by means of increased pitch
    Ozsvath, RR
    Casey, SO
    Alberico, RA
    Lamb, TJ
    Khan, A
    Herman, PG
    RADIOLOGY, 1996, 201 : 698 - 698
  • [22] CT based motion correction of dual gated cardiac PET images
    Klen, Riku
    Noponen, Tommi
    Koikkalainen, Juha
    Lotjonen, Jyrki
    Thielemans, Kris
    Hoppela, Erika
    Sipila, Hannu
    Teras, Mika
    Knuuti, Juhani
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [23] INCREASED SCAN PITCH FOR VASCULAR AND THORACIC SPIRAL CT
    RUBIN, GD
    NAPEL, S
    RADIOLOGY, 1995, 197 (01) : 316 - 317
  • [24] Bouveret's syndrome: diagnosis by helical CT scan
    Farman, Jack
    Goldstein, Daniel J.
    Sugalski, Matthew T.
    Moazami, Nader
    Amory, Spencer
    Clinical Imaging, 22 (04): : 240 - 242
  • [25] INFLUENCE OF SCAN PROTOCOLS ON IMAGE ARTIFACTS IN HELICAL CT
    TOMA, TA
    BREATNACH, ES
    RADIOLOGY, 1995, 197 : 202 - 202
  • [26] Bouveret's syndrome: Diagnosis by helical CT scan
    Farman, J
    Goldstein, DJ
    Sugalski, MT
    Moazami, N
    Amory, S
    CLINICAL IMAGING, 1998, 22 (04) : 240 - 242
  • [27] Classic helical CT scan findings of acute appendicitis
    Torbati, SS
    Chan, TC
    JOURNAL OF EMERGENCY MEDICINE, 2000, 18 (01): : 101 - 101
  • [28] Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging
    Lamare, F.
    Le Maitre, A.
    Dawood, M.
    Schaefers, K. P.
    Fernandez, P.
    Rimoldi, O. E.
    Visvikis, D.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [29] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [30] CEnPiT:: Helical cardiac CT reconstruction
    Bontus, Claas
    Koken, Peter
    Koehler, Thomas
    Grass, Michael
    MEDICAL PHYSICS, 2006, 33 (08) : 2792 - 2799