A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability

被引:9
|
作者
Hosein, Yara K. [1 ]
Dixon, S. Jeffrey [2 ]
Rizkalla, Amin S. [3 ]
Tassi, Ali [4 ]
机构
[1] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Div Grad Orthodont, London, ON, Canada
[2] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Dept Physiol & Pharmacol,Div Grad Orthodont, London, ON, Canada
[3] Western Univ, Schulich Sch Med Dent, Dept Chem & Biochem Engn, Div Grad Orthodont,Bone & Joint Inst,Fac Engn, London, ON, Canada
[4] Western Univ, Div Grad Orthodont, Schulich Sch Med & Dent, London, ON, Canada
关键词
torque; pull-out load; implant loosening; Periotest; mechanical retention; PULL-OUT STRENGTH; INSERTION TORQUE; SURFACE-TREATMENT; DAMPING CAPACITY; TAPER SHAPE; MINISCREWS; LENGTH; THREAD; IMPACT; DIAMETER;
D O I
10.1097/ID.0000000000000514
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability.Materials and Methods:Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs).Results:Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P < 0.05). The strongest correlations were found between IT and PV (r = -0.68) and between IT and POL (r = 0.66). Overall, PV showed the greatest variability (COV: 11%-100%) compared with IT (11%), POL (4%), and ScrD (19%).Conclusions:IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [31] Primary migration of a mini-implant under a functional orthodontic loading
    Joseph W. Pittman
    Anand Navalgund
    Steve H. Byun
    Hechang Huang
    Albert H. Kim
    Do-Gyoon Kim
    Clinical Oral Investigations, 2014, 18 : 721 - 728
  • [32] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 (01) : 1 - 6
  • [33] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jrg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, (01) : 1 - 6
  • [34] Prevalence and cause of mini-implant failure encountered by orthodontic residents
    Sreenivasagan S.
    Subramanian A.K.
    Rengalakshmi S.
    Journal of Long-Term Effects of Medical Implants, 2021, 31 (04) : 1 - 4
  • [35] Effects of surface treatment on the osseointegration potential of orthodontic mini-implant
    Jeon, Mi-Sun
    Kang, Yoon-Goo
    Mo, Sung-Seo
    Lee, Keun-Hye
    Kook, Yoon-Ah
    Kim, Seong-Hun
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (05) : 328 - 336
  • [36] Bone thickness of the palate for orthodontic mini-implant anchorage in adults
    Kang, Sungmin
    Lee, Shin-Jae
    Ahn, Sug-Joon
    Heo, Min-Suk
    Kim, Tae-Woo
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) : S74 - S81
  • [37] The impact of healing time before loading on orthodontic mini-implant stability: A histomorphometric study in minipigs
    Oltramari-Navarro, Paula V. P.
    Navarro, Ricardo L.
    Henriques, Jose Fernando C.
    Cestari, Tania M.
    Francischone, Carlos E.
    Taga, Rumio
    McNamara, James A., Jr.
    ARCHIVES OF ORAL BIOLOGY, 2013, 58 (07) : 806 - 812
  • [38] Influence of bone density, screw size and surgical procedure on orthodontic mini-implant placement - part B: implant stability
    Moehlhenrich, S. C.
    Heussen, N.
    Modabber, A.
    Bock, A.
    Hoelzle, F.
    Wilmes, B.
    Danesh, G.
    Szalma, J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (04) : 565 - 572
  • [39] Evaluation of orthodontic mini-implant anchorage in premolar extraction therapy in adolescents
    Garfinkle, Judah S.
    Cunningham, Larry L., Jr.
    Beeman, Cynthia S.
    Kluemper, G. Thomas
    Hicks, E. Preston
    Kim, Mi-Ok
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) : 642 - 653