A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability

被引:9
|
作者
Hosein, Yara K. [1 ]
Dixon, S. Jeffrey [2 ]
Rizkalla, Amin S. [3 ]
Tassi, Ali [4 ]
机构
[1] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Div Grad Orthodont, London, ON, Canada
[2] Western Univ, Bone & Joint Inst, Schulich Sch Med & Dent, Dept Physiol & Pharmacol,Div Grad Orthodont, London, ON, Canada
[3] Western Univ, Schulich Sch Med Dent, Dept Chem & Biochem Engn, Div Grad Orthodont,Bone & Joint Inst,Fac Engn, London, ON, Canada
[4] Western Univ, Div Grad Orthodont, Schulich Sch Med & Dent, London, ON, Canada
关键词
torque; pull-out load; implant loosening; Periotest; mechanical retention; PULL-OUT STRENGTH; INSERTION TORQUE; SURFACE-TREATMENT; DAMPING CAPACITY; TAPER SHAPE; MINISCREWS; LENGTH; THREAD; IMPACT; DIAMETER;
D O I
10.1097/ID.0000000000000514
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability.Materials and Methods:Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs).Results:Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P < 0.05). The strongest correlations were found between IT and PV (r = -0.68) and between IT and POL (r = 0.66). Overall, PV showed the greatest variability (COV: 11%-100%) compared with IT (11%), POL (4%), and ScrD (19%).Conclusions:IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [21] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shen, Shuning
    Sun, Yingying
    Zhang, Chen
    Yang, Yongjin
    Li, Zhiren
    Cai, Xingwei
    Duan, Yinzhong
    Li, Tao
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 109 - 116
  • [22] The effect of loading time on the stability of mini-implant
    Lee, Seung-Yeon
    Cha, Jung-Yul
    Yoon, Tae-min
    Park, Young-Chel
    KOREAN JOURNAL OF ORTHODONTICS, 2008, 38 (03): : 149 - 158
  • [23] Effects of Drilling Technology on Mini-Implant Primary Stability: A Comparison of the Mechanical Drilling and Femtosecond Laser Ablation
    Zhang, Wenbin
    Alghannam, Fahad
    Zhu, Yingchao
    Zhang, Jianfei
    Wohl, Gregory R.
    Haugen, Harold K.
    Qin, Zhipeng
    Xie, Guoqiang
    Fang, Qiyin
    Shen, Steve Guofang
    FRONTIERS IN PHYSICS, 2021, 9
  • [24] Primary migration of a mini-implant under a functional orthodontic loading
    Pittman, Joseph W.
    Navalgund, Anand
    Byun, Steve H.
    Huang, Hechang
    Kim, Albert H.
    Kim, Do-Gyoon
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (03) : 721 - 728
  • [25] Recommended placement torque when tightening an orthodontic mini-implant
    Motoyoshi, M
    Hirabayashi, M
    Uemura, M
    Shimizu, N
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (01) : 109 - 114
  • [26] Systematic review of mini-implant displacement under orthodontic loading
    Manuel Nienkemper
    Jörg Handschel
    Dieter Drescher
    International Journal of Oral Science, 2014, 6 : 1 - 6
  • [27] Systematic review of mini-implant displacement under orthodontic loading
    Nienkemper, Manuel
    Handschel, Joerg
    Drescher, Dieter
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2014, 6 (01) : 1 - 6
  • [28] Summary of: Advances in orthodontic anchorage with the use of mini-implant techniques
    Cousley, R. R. J.
    Sandler, P. J.
    BRITISH DENTAL JOURNAL, 2015, 218 (03) : 178 - 179
  • [29] A prospective study of factors associated with orthodontic mini-implant survival
    Tsai, Chia-Chun
    Chang, Hong-Po
    Pan, Chin-Yun
    Chou, Szu-Ting
    Tseng, Yu-Chuan
    JOURNAL OF ORAL SCIENCE, 2016, 58 (04) : 515 - 521
  • [30] Bivariate optimization of orthodontic mini-implant thread height and pitch
    Shuning Shen
    Yingying Sun
    Chen Zhang
    Yongjin Yang
    Zhiren Li
    Xingwei Cai
    Yinzhong Duan
    Tao Li
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 109 - 116