A concentration detection limit of 100 fM was achieved for the fluorescein ion by improving the experimental setup used for Hadamard transform capillary electrophoresis. Two argon-ion lasers, a gating laser for sample injection and a probe laser for the excitation of analyte molecules, were employed for the efficient photodegradation of analyte molecules in laser-induced fluorescence detection using an optically gated sample-injection method. In addition, a dichroic mirror, located in the pathway of the probe laser was used to exclude the other lines of the argon-ion laser. Using a Hadamard matrix on the order of 2046, the concentration limit of detection for fluorescein ion was determined to be 100 fM at S/N = 3, in which the average number of molecules in a single injection volume was calculated to be 27. The influences of the output power in both the gating and probe lasers on the sensitivity are also discussed.
引用
收藏
页码:1659 / 1661
页数:3
相关论文
共 50 条
  • [31] Optimization of separation and detection conditions for capillary electrophoresis mass spectrometry of small molecules
    Wheat, TE
    Lilley, KA
    Banks, JF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 116 - AGRO
  • [32] Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips
    Effenhauser, CS
    Bruin, GJM
    Paulus, A
    Ehrat, M
    ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3451 - 3457
  • [33] Improving precision of manual hydrodynamic injection in capillary electrophoresis with contactless conductivity detection
    Kuban, Petr
    Seiman, Andrus
    Kaljurand, Mihkel
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (09) : 1273 - 1280
  • [34] A new sequential injection analysis-capillary electrophoresis system with amperometric detection
    Feito, Rodrigo Fernandez
    Dinsdale, Richard M.
    Guwy, Alan J.
    Premier, Giuliano C.
    ELECTROPHORESIS, 2018, 39 (14) : 1754 - 1762
  • [35] Origin and correction of bias caused by sample injection and detection in capillary zone electrophoresis
    vanderMoolen, JN
    Boelens, HFM
    Poppe, H
    Smit, HC
    JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) : 103 - 113
  • [36] Fast Fourier transform square-wave voltammetry detection of phenothiazines in capillary electrophoresis
    Magnuszewska, J
    Krogulec, T
    Baranski, AS
    CHEMIA ANALITYCZNA, 2000, 45 (02): : 189 - 203
  • [37] Study of single cells by using capillary electrophoresis and native fluorescence detection
    Yeung, ES
    JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (02) : 243 - 262
  • [38] Single molecule DNA detection in microfabricated capillary electrophoresis chips.
    Haab, BB
    Mathies, RA
    BIOPHYSICAL JOURNAL, 1998, 74 (02) : A9 - A9
  • [39] Single molecule fluorescence burst detection of DNA separated by capillary electrophoresis
    Haab, BB
    Mathies, RA
    FLUORESCENCE DETECTION IV, PROCEEDINGS OF, 1996, 2705 : 162 - 169
  • [40] On-line and dual pre-concentration technique for large volume injection in capillary electrophoresis
    Li, Y
    He, YZ
    Hu, YY
    Wang, L
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (02) : 248 - 250