Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging

被引:25
|
作者
Hu, Chang-Hong [1 ]
Liu, Ruibin
Zhou, Qifa
Yen, Jesse
Shung, K. Kirk
机构
[1] Univ So Calif, Biomed Engn Dept, Los Angeles, CA 90089 USA
[2] Univ So Calif, NIH Transducer Resource Ctr, Los Angeles, CA 90089 USA
关键词
coded excitation; mismatched filter; high-frequency ultrasound;
D O I
10.1016/j.ultras.2006.04.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A scheme of using phase-coded excitation and mismatched filter compression for high-frequency ultrasound imaging is presented in this paper. Biphase-coded pulses were constructed to excite the transducer. Received signals were compressed with mismatched filters optimized by minimizing peak-sidelobe-level (PSL). Both simulation and experiments were carried out to demonstrate the advantage of this technique. The simulation results demonstrated a possible sidelobe reduction (<-90 dB) with a slightly decrease of the signal-to-noise ratio of less than 1 dB compared with the compression using matched filters alone. The experimental results showed about 14 dB SNR improvement as well as -40 dB sidelobe level when the Barker-13 code excitation with 3-cycle sinusoidal wave carrier was used. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:330 / 336
页数:7
相关论文
共 50 条
  • [1] Mismatched-Filter Design for Biphase-coded Pulse for High Frequency Ultrasound Imaging
    Hu, Chang-Hong
    Liu, Ruibin
    Zhou, Qifa
    Cannata, Jon
    Yen, Jesse
    Shung, K. Kirk
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2222 - +
  • [2] Coded excitation and annular arrays for high-frequency ultrasound imaging
    Mamou, Jonathan
    Ketterlino, Jeffrey A.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2070 - +
  • [3] Chirp-coded excitation imaging with a high-frequency ultrasound annular array
    Mamou, Jonathan
    Ketterling, Jeffrey A.
    Silverman, Ronald H.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) : 508 - 513
  • [4] REPROGRAMMABLE OPTICAL MATCHED-FILTER FOR BIPHASE-CODED PULSE-COMPRESSION
    SHEN, XA
    BAI, YS
    KACHRU, R
    [J]. OPTICS LETTERS, 1992, 17 (15) : 1079 - 1081
  • [5] Effect of frequency characteristic of excitation pulse on lateral spatial resolution in coded ultrasound imaging
    Fujita, Hiroki
    Hasegawa, Hideyuki
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [6] Enhanced ultrasound strain imaging using chirp-coded pulse excitation
    Peng, Hui
    Liu, Dong C.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (02) : 130 - 141
  • [7] Chirp-Coded Pulse Excitation for Ultrasound Elasticity Imaging
    Peng, Hui
    Liu, Dong C.
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [8] Speckle Reduction for Ultrasonic Imaging Using Frequency Compounding and Despeckling Filters along with Coded Excitation and Pulse Compression
    Ullom, Joshua S.
    Oelze, Michael L.
    Sanchez, Jose R.
    [J]. ADVANCES IN ACOUSTICS AND VIBRATION, 2012, 2012
  • [9] Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: A feasibility study
    Shekhar, Himanshu
    Doyley, Marvin M.
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 2049 - 2060
  • [10] High-frequency subharmonic emission with chirp-coded excitation: implications for imaging
    Shekhar, Himanshu
    Doyley, Marvin M.
    [J]. MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320