Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: A feasibility study

被引:21
|
作者
Shekhar, Himanshu [1 ]
Doyley, Marvin M. [1 ]
机构
[1] Univ Rochester, Rochester, NY 14627 USA
关键词
coronary artery disease; ultrasound contrast agents; vasa vasorum; subharmonic imaging; coded excitation; ULTRASOUND CONTRAST AGENTS; INTRAVASCULAR ULTRASOUND; VASA VASORUM; MICROBUBBLES; OSCILLATIONS; GENERATION; BUBBLES; ATHEROSCLEROSIS; MICROVESSELS; ENHANCEMENT;
D O I
10.1118/1.3694101
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Subharmonic intravascular ultrasound imaging (S-IVUS) could visualize the adventitial vasa vasorum, but the high pressure threshold required to incite subharmonic behavior in an ultra-sound contrast agent will compromise sensitivity-a trait that has hampered the clinical use of S-IVUS. The purpose of this study was to assess the feasibility of using coded-chirp excitations to improve the sensitivity and axial resolution of S-IVUS. Methods: The subharmonic response of Targestar-p (TM), a commercial microbubble ultrasound contrast agent (UCA), to coded-chirp (5%-20% fractional bandwidth) pulses and narrowband sine-burst (4% fractional bandwidth) pulses was assessed, first using computer simulations and then experimentally. Rectangular windowed excitation pulses with pulse durations ranging from 0.25 to 3 mu s were used in all studies. All experimental studies were performed with a pair of transducers (20 MHz/10 MHz), both with diameter of 6.35 mm and focal length of 50 mm. The size distribution of the UCA was measured with a Casy (TM) Cell counter. Results: The simulation predicted a pressure threshold that was an order of magnitude higher than that determined experimentally. However, all other predictions were consistent with the experimental observations. It was predicted that: (1) exciting the agent with chirps would produce stronger subharmonic response relative to those produced by sine-bursts; (2) increasing the fractional bandwidth of coded-chirp excitation would increase the sensitivity of subharmonic imaging; and (3) coded-chirp would increase axial resolution. The experimental results revealed that subharmonic-to-fundamental ratios obtained with chirps were 5.7 dB higher than those produced with sine-bursts of similar duration. The axial resolution achieved with 20% fractional bandwidth chirps was approximately twice that achieved with 4% fractional bandwidth sine-bursts. Conclusions: The coded-chirp method is a suitable excitation strategy for subharmonic IVUS imaging. At the 20 MHz transmission frequency and 20% fractional bandwidth, coded-chirp excitation appears to represent the ideal tradeoff between subharmonic strength and axial resolution. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694101]
引用
收藏
页码:2049 / 2060
页数:12
相关论文
共 50 条
  • [1] High-frequency subharmonic emission with chirp-coded excitation: implications for imaging
    Shekhar, Himanshu
    Doyley, Marvin M.
    [J]. MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [2] Coded excitation and annular arrays for high-frequency ultrasound imaging
    Mamou, Jonathan
    Ketterlino, Jeffrey A.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2070 - +
  • [3] Chirp-coded excitation imaging with a high-frequency ultrasound annular array
    Mamou, Jonathan
    Ketterling, Jeffrey A.
    Silverman, Ronald H.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) : 508 - 513
  • [4] Wideband Linear Power Amplifier for High-Frequency Ultrasonic Coded Excitation Imaging
    Park, Jinhyoung
    Hu, Changhong
    Li, Xiang
    Zhou, Qifa
    Shung, K. Kirk
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) : 825 - 832
  • [5] Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging
    Hu, Chang-Hong
    Liu, Ruibin
    Zhou, Qifa
    Yen, Jesse
    Shung, K. Kirk
    [J]. ULTRASONICS, 2006, 44 (03) : 330 - 336
  • [6] High-Frequency Subharmonic Imaging of Liposome-Loaded Microbubbles
    McLaughlan, James
    Ingram, Nicola
    Abou-Saleh, Radwa
    Harput, Sevan
    Evans, Tony
    Evans, Stephen
    Coletta, Louise
    Freear, Steven
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1493 - 1496
  • [7] Improving sensitivity in acoustoelectric imaging with coded excitation and optimized inverse filter
    Tseng, Hsin-Wu
    Qin, Yexian
    O'Donnell, Matthew
    Witte, Russell S.
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [8] Coded excitation for diverging wave cardiac imaging: a feasibility study
    Zhao, Feifei
    Tong, Ling
    He, Qiong
    Luo, Jianwen
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04): : 1565 - 1584
  • [9] Acoustic Radiation Force Impulse (ARFI) Imaging of Zebrafish Embryo by High-Frequency Coded Excitation Sequence
    Jinhyoung Park
    Jungwoo Lee
    Sien Ting Lau
    Changyang Lee
    Ying Huang
    Ching-Ling Lien
    K. Kirk Shung
    [J]. Annals of Biomedical Engineering, 2012, 40 : 907 - 915
  • [10] Acoustic Radiation Force Impulse (ARFI) Imaging of Zebrafish Embryo by High-Frequency Coded Excitation Sequence
    Park, Jinhyoung
    Lee, Jungwoo
    Lau, Sien Ting
    Lee, Changyang
    Huang, Ying
    Lien, Ching-Ling
    Shung, K. Kirk
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (04) : 907 - 915