Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis

被引:68
|
作者
Mahmood, Maryam [1 ]
Kendi, Ayse Tuba [2 ]
Farid, Saira [1 ]
Ajmal, Saira [1 ]
Johnson, Geoffrey B. [2 ,3 ]
Baddour, Larry M. [1 ,4 ]
Chareonthaitawee, Panithaya [4 ]
Friedman, Paul A. [4 ]
Sohail, M. Rizwan [1 ,4 ]
机构
[1] Mayo Clin, Div Infect Dis, Dept Med, Coll Med & Sci, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Nucl Med, Dept Radiol, Coll Med & Sci, Rochester, MN USA
[3] Mayo Clin, Dept Immunol, Coll Med & Sci, Rochester, MN USA
[4] Mayo Clin, Dept Cardiovasc Med, Coll Med & Sci, Rochester, MN USA
关键词
CIED; PET; infection; imaging; meta-analysis; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; PATIENT PREPARATION; CARDIAC DEVICE; FDG-PET/CT; ENDOCARDITIS; IMPACT; MANAGEMENT; OUTCOMES; PACEMAKER; ACCURACY;
D O I
10.1007/s12350-017-1063-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveWe performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose (F-18-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections.BackgroundPET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings.MethodsPubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections.ResultsOverall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%).ConclusionUse of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.
引用
收藏
页码:958 / 970
页数:13
相关论文
共 50 条
  • [31] In response to Letter regarding "Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis"
    Mahmood, Maryam
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (03) : 941 - 943
  • [32] Effectiveness of 18F-FDG PET/CT in the diagnosis and staging of osteosarcoma: a meta-analysis of 26 studies
    Fanxiao Liu
    Qingyu Zhang
    Dongsheng Zhou
    Jinlei Dong
    BMC Cancer, 19
  • [33] Usefulness of 18F-FDG PET/CT in Patients with Cardiac Implantable Electronic Device Suspected of Late Infection
    Rubini, Giuseppe
    Ferrari, Cristina
    Carretta, Domenico
    Santacroce, Luigi
    Ruta, Rossella
    Iuele, Francesca
    Lavelli, Valentina
    Merenda, Nunzio
    D'Agostino, Carlo
    Sardaro, Angela
    Asabella, Artor Niccoli
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 13
  • [34] CLINICAL UTILITY OF PET/CT 18F-FDG IN PATIENTS WITH SUSPECTED CARDIAC IMPLANTABLE ELECTRONIC DEVICE INFECTION
    Carretta, D.
    Santacroce, L.
    Iuele, F.
    Ruta, R.
    Rubini, G.
    Colonna, P.
    D'Agostino, C.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0G) : G161 - G161
  • [35] The role of 18F-FDG PET/CT in the diagnosis of frozen shoulder
    Linus Daniel Leonhard Duchstein
    Jens Rithamer Jakobsen
    Line Marker
    Mads Okholm
    Lars Friberg
    Lene Simonsen
    Michael Rindom Krogsgaard
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 210 - 215
  • [36] 18F-FDG PET/CT in the diagnosis of occult bacterial infections in children
    del Rosal, Teresa
    Goycochea, Walter A.
    Mendez-Echevarria, Ana
    Garcia-Fernandez de Villalta, Marta
    Baquero-Artigao, Fernando
    Coronado, Monica
    Dolores Marin, Maria
    Albajara, Luis
    EUROPEAN JOURNAL OF PEDIATRICS, 2013, 172 (08) : 1111 - 1115
  • [37] 18F-FDG PET/CT in the diagnosis of occult bacterial infections in children
    Teresa del Rosal
    Walter A. Goycochea
    Ana Méndez-Echevarría
    Marta García-Fernández de Villalta
    Fernando Baquero-Artigao
    Mónica Coronado
    Maria Dolores Marín
    Luis Albajara
    European Journal of Pediatrics, 2013, 172 : 1111 - 1115
  • [38] Prognostic Value of 18F-FDG PET/CT in Surgical NSCLC: A Meta-Analysis
    Liu, Jing
    Dong, Min
    Xing, Ligang
    Sun, Xiaorong
    JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S181 - S181
  • [39] 18F-FDG PET/CT AS A NEW IMAGING MODALITY FOR DIAGNOSIS OF CARDIAC DEVICE INFECTIONS (PET-ID)
    Sarrazin, J.
    Philippon, F.
    Tessler, M.
    Gulmond, J.
    Nadeau, M.
    Molln, F.
    Champagne, J.
    Trottler, M.
    Nault, I.
    Biler, L.
    O'Hara, G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S261 - S261
  • [40] Accuracy of 18F-FDG PET/CT in patients with the suspicion of cardiac implantable electronic device infections: good for pocket, not so good for endocarditis
    Jeronimo Baza, A.
    Olmos, C.
    Vilacosta, I
    Ortega-Candil, A.
    Rodriguez-Rey, C.
    Perez-Castejon, M. J.
    Fernandez-Perez, C.
    Perez-Garcia, C. N.
    Garcia-Arribas, D.
    Ferrera, C.
    Carreras, J. L.
    EUROPEAN HEART JOURNAL, 2020, 41 : 285 - 285