Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis

被引:68
|
作者
Mahmood, Maryam [1 ]
Kendi, Ayse Tuba [2 ]
Farid, Saira [1 ]
Ajmal, Saira [1 ]
Johnson, Geoffrey B. [2 ,3 ]
Baddour, Larry M. [1 ,4 ]
Chareonthaitawee, Panithaya [4 ]
Friedman, Paul A. [4 ]
Sohail, M. Rizwan [1 ,4 ]
机构
[1] Mayo Clin, Div Infect Dis, Dept Med, Coll Med & Sci, 200 1st St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Nucl Med, Dept Radiol, Coll Med & Sci, Rochester, MN USA
[3] Mayo Clin, Dept Immunol, Coll Med & Sci, Rochester, MN USA
[4] Mayo Clin, Dept Cardiovasc Med, Coll Med & Sci, Rochester, MN USA
关键词
CIED; PET; infection; imaging; meta-analysis; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; PATIENT PREPARATION; CARDIAC DEVICE; FDG-PET/CT; ENDOCARDITIS; IMPACT; MANAGEMENT; OUTCOMES; PACEMAKER; ACCURACY;
D O I
10.1007/s12350-017-1063-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveWe performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose (F-18-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections.BackgroundPET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings.MethodsPubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections.ResultsOverall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%).ConclusionUse of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.
引用
收藏
页码:958 / 970
页数:13
相关论文
共 50 条
  • [21] Role of 18F-FDG PET/CT in infection of cardiovascular implantable electronic devices: review of the literature and initial experience
    Bhoil, Amit
    Vinjamuri, Sobhan
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (06) : 555 - 564
  • [22] Letter regarding "Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis"
    Scholtens, Asbjorn M.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (03) : 939 - 940
  • [23] Meta-analysis of 18F-FDG PET/CT in diagnosis and prognostic evaluation of thoracic sarcoidosis
    Donnelly, Ryan
    Mc Dermott, Michael
    Mc Manus, Gerry
    Franciosi, Alessandro N.
    Keane, Michael P.
    Mc Grath, Emmet E.
    Mc Carthy, Cormac
    Murphy, David J.
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [24] Letter regarding “Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis”
    Asbjørn M. Scholtens
    Journal of Nuclear Cardiology, 2019, 26 : 939 - 940
  • [25] The value of 18F-FDG PET/CT for the diagnosis of device-related infections in patients with a left ventricular assist device: a systematic review and meta-analysis
    D. ten Hove
    G. Treglia
    R. H. J. A. Slart
    K. Damman
    M. Wouthuyzen-Bakker
    D. F. Postma
    O. Gheysens
    R. J. H. Borra
    G. Mecozzi
    P. P. van Geel
    B. Sinha
    A. W. J. M. Glaudemans
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 241 - 253
  • [26] The role of 18F-FDG PET/CT in infectious endocarditis: a systematic review and meta-analysis
    Yan, Jinzhu
    Zhang, Chao
    Niue, Yuming
    Yuan, Ruixia
    Zeng, Xiantao
    Ge, Xingyao
    Yang, Yi
    Peng, Xinyu
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2016, 54 (05) : 337 - 342
  • [27] Respective role of 18F-FDG PET/CT and WBC SPECT/CT in the diagnosis of cardiac implantable electronic devices infection.
    Calais, J.
    Touati, A.
    Grall, N.
    Benali, K.
    Mahida, B.
    Hyafil, F.
    Iung, B.
    Duval, X.
    Le Guludec, D.
    Rouzet, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S206 - S207
  • [29] In response to Letter regarding “Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis”
    Maryam Mahmood
    Journal of Nuclear Cardiology, 2019, 26 : 941 - 943
  • [30] Effectiveness of 18F-FDG PET/CT in the diagnosis and staging of osteosarcoma: a meta-analysis of 26 studies
    Liu, Fanxiao
    Zhang, Qingyu
    Zhou, Dongsheng
    Dong, Jinlei
    BMC CANCER, 2019, 19 (1)