Determination of Cu, Fe, Mn and Zn by flame atomic absorption spectrometry in multivitamin/multimineral dosage forms or tablets after an acidic extraction

被引:40
|
作者
Soriano, Silvio
Netto, Annibal D. Pereira
Cassella, Ricardo J.
机构
[1] Univ Fed Fluminense, Inst Quim, Dept Quim Analit, BR-24020150 Niteroi, RJ, Brazil
[2] Unidade Rio De Janeiro, CEFET Quim, Rio De Janeiro, Brazil
[3] Univ Fed Fluminense, Inst Quim, Programa Pos Grad Quim, BR-24020150 Niteroi, RJ, Brazil
关键词
extraction; metals; multivitamin tablets; flame atomic absorption spectrometry;
D O I
10.1016/j.jpba.2006.06.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents the development of a methodology for the determination of Cu, Fe, Mn and Zn in samples of multivitamin/multimineral tablets, by flame atomic absorption spectrometry (FAAS), after extraction of the analytes with diluted hydrochloric acid solution. Several parameters that could influence the extraction process such as acid extraction solution concentration and nature, mixing mode (ultrasonic or magnetic stirring), extraction time and sample composition were evaluated. The obtained results showed that Fe, Mn and Zn were easily extracted with 1 mol/L HCl solution after 5 min of mixing with either ultrasonic or magnetic stirring for all studied samples. On the other hand, Cu extraction appeared to be more complex since it could only be extracted at the same conditions for silicate-free samples. For samples containing silicates the time of contact between solid sample and extraction solution presented remarkable influence, being necessary up to 12 h to achieve quantitative recovery with 1 mol/L HCl solution. The developed methodology was applied in the determination of Cu, Fe, Mn and Zn in seven commercially available multivitamin/multimineral tablets. The results obtained with the developed method were compared with those obtained after total digestion of samples using a closed-vessel microwave oven device. (c) 2006 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:304 / 310
页数:7
相关论文
共 50 条
  • [31] Determination of manganese in mater samples by flame atomic absorption spectrometry after cloud point extraction
    Teo, KC
    Chen, JR
    ANALYST, 2001, 126 (04) : 534 - 537
  • [32] Development of an ultrasonic slurry sampling method for the determination of Cu and Mn in antibiotic tablets by electrothermal atomic absorption spectrometry
    de Paula, Carlos Eduardo R.
    Caldas, Luiz Fernando S.
    Brum, Daniel M.
    Cassella, Ricardo J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 197 - 203
  • [33] Cloud point extraction and preconcentration for the determination of Cu and Ni in natural water by flame atomic absorption spectrometry
    Shemirani, Farzaneh
    Jamali, Mohammad Reza
    Kozani, Reyhaneh Rahnama
    Salavati-Niasari, Masood
    SEPARATION SCIENCE AND TECHNOLOGY, 2006, 41 (13) : 3065 - 3077
  • [34] Determination of Cu, Zn, Fe, Ni and Cd by flame atomic absorption spectrophotometry after preconcentration by Escherichia coli immobilized on sepiolite
    Bag, H
    Türker, AR
    Lale, M
    TALANTA, 2000, 51 (05) : 1035 - 1043
  • [35] Multivariate optimization of a microwave-assisted leaching procedure using dilute acid solutions, for FAAS determination of Cu, Fe, Mn, and Zn in multivitamin/multimineral supplements
    Soriano, Silvio
    Netto, Annibal D. Pereira
    Cassella, Ricardo J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (03) : 1113 - 1120
  • [36] Determination of Mn, Cu and Zn in saline matrices by flame atomic absorption spectrometry after separation and preconcentration on amberlite XAD-7 impregnated with Alizarin Red S
    Santos, AD
    Korn, MDA
    Jaeger, HV
    Silva, NMS
    Costa, ACS
    QUIMICA NOVA, 2002, 25 (6B): : 1086 - 1090
  • [37] Determination ofsoil-extracted Fe, Zn, Cu and Mn by different extractors by inductively coupled plasma optical emission spectrometry and atomic absorption spectrometry
    de Miranda Milagres, Joao Jose
    Alvarez V., Victor Hugo
    Cantarutti, Reinaldo Bertola
    Lima Neves, Julio Cesar
    REVISTA BRASILEIRA DE CIENCIA DO SOLO, 2007, 31 (02): : 237 - 245
  • [38] Evaluation of alternate lines of Fe for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry
    Raposo Junior, Jorge Luiz
    de Oliveira, Silvana Ruella
    Caldas, Naise Mary
    Gomes Neto, Jose Anchieta
    ANALYTICA CHIMICA ACTA, 2008, 627 (02) : 198 - 202
  • [39] Direct Determination of Cd, Co, Cu, Fe, Mn, Na, Ni, Pb, and Zn in Ethanol Fuel by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry
    Leite, Clarice C.
    de Jesus, Alexandre
    Potes, Mariana L.
    Vieira, Mariana A.
    Samios, Dimitrios
    Silva, Marcia M.
    ENERGY & FUELS, 2015, 29 (11) : 7358 - 7363
  • [40] Determination of the Hydrophobic Fraction of Ca, Fe, Mg and Zn in Dark Color Honeys Using Solid Phase Extraction and Flame Atomic Absorption Spectrometry
    Pohl, Pawel
    Stecka, Helena
    Greda, Krzysztof
    Jamroz, Piotr
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (06) : 1098 - 1103