Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen

被引:30
|
作者
Shahryari, Mehrgan [1 ]
Meyer, Tom [1 ]
Warmuth, Carsten [1 ]
Herthum, Helge [1 ]
Bertalan, Gergely [1 ]
Tzschatzsch, Heiko [1 ]
Stencel, Lisa [1 ]
Lukas, Steffen [1 ]
Lilaj, Ledia [1 ]
Braun, Jurgen [2 ]
Sack, Ingolf [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
[2] Charite Univ Med Berlin, Inst Med Informat, Berlin, Germany
关键词
abdomen; breathing artifacts; image registration; multifrequency MRE; navigator; stiffness; MR ELASTOGRAPHY; HEPATIC-FIBROSIS; LIVER STIFFNESS; TOMOELASTOGRAPHY; PANCREAS;
D O I
10.1002/mrm.28558
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath-hold. However, breath-hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free-breathing strategies in multifrequency MRE of abdominal organs. Methods Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single-shot, multislice, full wave-field acquisition was performed four times in 11 healthy volunteers: once with multiple breath-holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian. Results Total scan times ranged from 120 seconds for ungated free-breathing MRE to 376 seconds for breath-hold examinations. As expected, free-breathing MRE resulted in larger organ displacements (liver, 4.7 +/- 1.5 mm; kidneys, 2.4 +/- 2.2 mm; spleen, 3.1 +/- 2.4 mm; pancreas, 3.4 +/- 1.4 mm) than breath-hold MRE (liver, 0.7 +/- 0.2 mm; kidneys, 0.4 +/- 0.2 mm; spleen, 0.5 +/- 0.2 mm; pancreas, 0.7 +/- 0.5 mm). Nonetheless, breathing-related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 +/- 0.07 m/s; kidneys, 2.35 +/- 0.21 m/s; spleen, 2.02 +/- 0.15 m/s; pancreas, 1.39 +/- 0.15 m/s). Image registration before inversion improved the quality of free-breathing examinations, yielding no differences in image sharpness to uncorrected breath-hold MRE in most organs (P > .05). Conclusion Overall, multifrequency MRE is robust to breathing when considering whole-organ values. Respiration-related blurring can readily be corrected using image registration. Consequently, ungated free-breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.
引用
收藏
页码:1962 / 1973
页数:12
相关论文
共 50 条
  • [41] Artifacts in Magnetic Resonance Imaging
    Krupa, Katarzyna
    Bekiesinska-Figatowska, Monika
    POLISH JOURNAL OF RADIOLOGY, 2015, 80 : 93 - 106
  • [42] TUNEABLE RESONANCE ACTUATORS FOR MAGNETIC RESONANCE ELASTOGRAPHY
    Meinhold, Waiman
    Ozkaya, Efe
    Ueda, Jun
    Kurt, Mehmet
    2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,
  • [43] Dose effect of dicyclomine on the reduction of peristaltic artifacts on MRI of the abdomen
    Martí-Bonmatí, L
    Dosdá, R
    Ronchera-Oms, CL
    Casillas, C
    ABDOMINAL IMAGING, 1999, 24 (04): : 336 - 339
  • [44] Dose effect of dicyclomine on the reduction of peristaltic artifacts on MRI of the abdomen
    L. Martí-Bonmatí
    R. Dosdá
    C. L. Ronchera-Oms
    C. Casillas
    Abdominal Imaging, 1999, 24 : 336 - 339
  • [45] Reduction of Gibbs Artifacts in Magnetic Resonance Imaging Based on Convolutional Neural Network
    Wang, Yida
    Song, Yang
    Xie, Haibin
    Li, Wenjing
    Hu, Bingwen
    Yang, Guang
    2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [46] MAGNETIC-RESONANCE-IMAGING OF THE ABDOMEN
    LEE, JKT
    TOPICS IN MAGNETIC RESONANCE IMAGING, 1995, 7 (02) : 69 - 69
  • [47] Microscopic multifrequency magnetic resonance elastography of ex vivo abdominal aortic aneurysms for extracellular matrix imaging in a mouse model
    Mangarova, Dilyana B.
    Bertalan, Gergely
    Jordan, Jakob
    Brangsch, Julia
    Kader, Avan
    Moeckel, Jana
    Adams, Lisa C.
    Sack, Ingolf
    Taupitz, Matthias
    Hamm, Bernd
    Braun, Juergen
    Makowski, Marcus R.
    ACTA BIOMATERIALIA, 2022, 140 : 389 - 397
  • [48] Magnetic resonance imaging and the acute abdomen
    Stoker, J.
    BRITISH JOURNAL OF SURGERY, 2008, 95 (10) : 1193 - 1194
  • [49] Editorial for "Combining Multifrequency Magnetic Resonance Elastography with Automatic Segmentation to Assess Renal Function in Patients With Chronic Kidney Disease"
    Idilman, Ilkay S.
    Karcaaltincaba, Musturay
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025,
  • [50] Simultaneous acquisition of vibration and diffusion by multifrequency diffusion tensor imaging-magnetic resonance elastography (mDTI-MRE)
    Klatt, Dieter
    Lin, Shujun
    Magin, Richard
    Anderson, Aaron T.
    Sutton, Bradley P.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):