Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen

被引:30
|
作者
Shahryari, Mehrgan [1 ]
Meyer, Tom [1 ]
Warmuth, Carsten [1 ]
Herthum, Helge [1 ]
Bertalan, Gergely [1 ]
Tzschatzsch, Heiko [1 ]
Stencel, Lisa [1 ]
Lukas, Steffen [1 ]
Lilaj, Ledia [1 ]
Braun, Jurgen [2 ]
Sack, Ingolf [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
[2] Charite Univ Med Berlin, Inst Med Informat, Berlin, Germany
关键词
abdomen; breathing artifacts; image registration; multifrequency MRE; navigator; stiffness; MR ELASTOGRAPHY; HEPATIC-FIBROSIS; LIVER STIFFNESS; TOMOELASTOGRAPHY; PANCREAS;
D O I
10.1002/mrm.28558
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath-hold. However, breath-hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free-breathing strategies in multifrequency MRE of abdominal organs. Methods Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single-shot, multislice, full wave-field acquisition was performed four times in 11 healthy volunteers: once with multiple breath-holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian. Results Total scan times ranged from 120 seconds for ungated free-breathing MRE to 376 seconds for breath-hold examinations. As expected, free-breathing MRE resulted in larger organ displacements (liver, 4.7 +/- 1.5 mm; kidneys, 2.4 +/- 2.2 mm; spleen, 3.1 +/- 2.4 mm; pancreas, 3.4 +/- 1.4 mm) than breath-hold MRE (liver, 0.7 +/- 0.2 mm; kidneys, 0.4 +/- 0.2 mm; spleen, 0.5 +/- 0.2 mm; pancreas, 0.7 +/- 0.5 mm). Nonetheless, breathing-related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 +/- 0.07 m/s; kidneys, 2.35 +/- 0.21 m/s; spleen, 2.02 +/- 0.15 m/s; pancreas, 1.39 +/- 0.15 m/s). Image registration before inversion improved the quality of free-breathing examinations, yielding no differences in image sharpness to uncorrected breath-hold MRE in most organs (P > .05). Conclusion Overall, multifrequency MRE is robust to breathing when considering whole-organ values. Respiration-related blurring can readily be corrected using image registration. Consequently, ungated free-breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.
引用
收藏
页码:1962 / 1973
页数:12
相关论文
共 50 条
  • [21] Analysis of time reduction methods for magnetic resonance elastography of the brain
    Murphy, Matthew C.
    Glaser, Kevin J.
    Manduca, Armando
    Felmlee, Joel P.
    Huston, Jon, III
    Ehman, Richard L.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (10) : 1514 - 1524
  • [22] Magnetic Resonance Elastography
    Litwiller, Daniel V.
    Mariappan, Yogesh K.
    Ehman, Richard L.
    CURRENT MEDICAL IMAGING REVIEWS, 2012, 8 (01) : 46 - 55
  • [23] Magnetic resonance elastography
    Muthupillai, R
    Ehman, RL
    NATURE MEDICINE, 1996, 2 (05) : 601 - 603
  • [24] Magnetic resonance elastography
    Sack, I.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2008, 133 (06) : 247 - 251
  • [25] Prediction of clinically relevant postoperative pancreatic fistula after pancreatoduodenectomy based on multifrequency magnetic resonance elastography
    Zhong, Yu-Qing
    Zhu, Xiao-Xu
    Huang, Xi-Tai
    Luo, Yan-Ji
    Huang, Chen-song
    Xu, Qiong-cong
    Yin, Xiao-Yu
    JOURNAL OF GASTROINTESTINAL SURGERY, 2025, 29 (02)
  • [26] Three-dimensional multifrequency magnetic resonance elastography improves preoperative assessment of proliferative hepatocellular carcinoma
    Guixue Liu
    Di Ma
    Huafeng Wang
    Jiahao Zhou
    Zhehan Shen
    Yuchen Yang
    Yongjun Chen
    Ingolf Sack
    Jing Guo
    Ruokun Li
    Fuhua Yan
    Insights into Imaging, 14
  • [27] Three-dimensional multifrequency magnetic resonance elastography improves preoperative assessment of proliferative hepatocellular carcinoma
    Liu, Guixue
    Ma, Di
    Wang, Huafeng
    Zhou, Jiahao
    Shen, Zhehan
    Yang, Yuchen
    Chen, Yongjun
    Sack, Ingolf
    Guo, Jing
    Li, Ruokun
    Yan, Fuhua
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [28] Multifrequency magnetic resonance elastography-based tomoelastography of the parotid glands-feasibility and reference values
    Elsholtz, Fabian Henry Juergen
    Reiter, Rolf
    Garcia, Stephan Rodrigo Marticorena
    Braun, Juergen
    Sack, Ingolf
    Hamm, Bernd
    Schaafs, Lars-Arne
    DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (01)
  • [29] Reduction of magnetic resonance image artifacts of NiTi implant by carbon coating
    Han, Taeyang
    Sohn, Youhan
    Park, Sang Jin
    Kim, Yu-Chan
    Lee, Kang Sik
    Kim, Hye Sung
    Yoon, Soon-Gil
    Kim, Dojin
    Han, Jun Hyun
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 1 - 8
  • [30] Magnetic Resonance Elastography of Liver
    Venkatesh, Sudhakar Kundapur
    Ehman, Richard L.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (03) : 433 - +