The use of semi-compliant versus non-compliant balloon systems for predilatation during the implantation of self-expandable transcatheter aortic valves Data from the VIenna CardioThOracic Aortic Valve RegistrY (VICTORY)

被引:5
|
作者
Mach, Markus [1 ,2 ]
Szalkiewicz, Philipp [1 ,2 ]
Poschner, Thomas [1 ]
Hasan, Waseem [3 ]
Andreas, Martin [1 ]
Winkler, Bernhard [2 ]
Hasimbegovic, Ena [1 ,4 ]
Steinkellner, Theresia [5 ]
Strouhal, Andreas [6 ]
Adlbrecht, Christopher [6 ,7 ]
Delle-Karth, Georg [6 ]
Grabenwoeger, Martin [2 ,8 ]
机构
[1] Med Univ Vienna, Dept Cardiac Surg, Vienna Gen Hosp, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Clin Floridsdorf & Karl Landsteiner Inst Cardiova, Heart Team Vienna, Dept Cardiovasc Surg, Vienna, Austria
[3] Imperial Coll London, Fac Med, London, England
[4] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna Gen Hosp, Vienna, Austria
[5] Med Univ Vienna, Div Anat, Ctr Anat & Cell Biol, Vienna Gen Hosp, Vienna, Austria
[6] Clin Floridsdorf & Karl Landsteiner Inst Cardiova, Dept Cardiol, Vienna, Austria
[7] Imed19 Privat, Private Clin Res Ctr, Vienna, Austria
[8] Sigmund Freud Univ, Fac Med, Vienna, Austria
关键词
balloon; compliant; non‐ predilatation; self‐ expanding; TAVI; TAVR; transcatheter; valve; CORONARY ANGIOPLASTY; VALVULOPLASTY; REPLACEMENT; MODERATE; SAFETY; FEASIBILITY; PREDICTORS; STENOSIS; EFFICACY; RUPTURE;
D O I
10.1111/eci.13570
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This study aimed to evaluate the differences in outcome arising from the use of semi-compliant (SCB) versus non-compliant balloon (NCB) systems for predilatation during self-expanding transcatheter aortic valve replacement (TAVR). Methods 251 TAVR procedures with the implantation of self-expanding valves after predilatation were analyzed. SCB systems were used in 166 and NCB systems in 85 patients. The primary endpoint was defined as device success, a composite endpoint comprising the absence of procedural mortality, correct valve positioning, adequate valve performance and the absence of more than a mild paravalvular leak. The secondary endpoints were chosen in accordance with the valve academic research consortium (VARC-2) endpoint definitions. Results No significant differences were observed with regard to procedural device success between the SCB- and NCB cohort (SCB: 142 [85.5%%] vs. NCB: 77 [90.6%]; P = .257). There was a notable difference between the rates of conversion to open surgery and the postdilatation rate, both of which were higher for the NCB group (SCB: 1 [0.6%] vs. NCB: 4 [5.1%]; P = .042; SCB: 30 [18.1%] vs. NCB: 34 [40%]; P < .001). In a multivariate logistic regression analysis, the use of semi-compliant balloon systems for predilatation was associated with a lower risk for postdilatation (OR: 0.296; 95% CI: 0.149-0.588) and conversion to open surgery (OR: 0.205; 95% CI: 0.085-0.493; P = .001) but not for device success. Conclusion While the balloon compliance did not affect the procedural mortality, device success or the rate of paravalvular leakage, the use of semi-compliant balloons for predilatation during TAVR should be investigated in larger randomized trials in the light of the lower rates of postdilatation and conversion to open surgery compared to their non-compliant counterparts.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Short-term safety and efficacy of transcarotid transcatheter aortic valve implantation with balloon-expandable vs. self-expandable valves
    Hudziak, Damian
    Wanha, Wojciech
    Gocot, Radoslaw
    Parma, Radoslaw
    Ochala, Andrzej
    Smolka, Grzegorz
    Ciosek, Joanna
    Darocha, Tomasz
    Deja, Marek A.
    Wojakowski, Wojciech
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 75 - 81
  • [32] The Incidence of Transcatheter Aortic Valve Implantation-Related Heart Block in Self-Expandable Medtronic CoreValve and Balloon-Expandable Edwards Valves
    Liang, Michael
    Devlin, Gerard
    Pasupati, Sanjeevan
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (04): : 173 - 176
  • [33] Which regimen is the best choice? The impact of antiplatelet and antithrombotic therapy on outcome and survival transcatheter aortic valve implantation. Data from the VIenna CardioThOracic Aortic Valve RegistrY (VICTORY)
    Polat, E.
    Koschutnik, M.
    Poschner, T.
    Cuhaij, C.
    Santer, D.
    Wallner, S.
    Adlbrecht, C.
    Delle Karth, G.
    Grabenwoeger, M.
    Mach, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 155 - 156
  • [34] Comparison of Balloon-Expandable Versus a Self-Expandable Valves for Transcatheter Aortic Valve Implantation in Patients With Low-Gradient Severe Aortic Stenosis and Preserved Left Ventricular Ejection Fraction
    Covolo, Elisa
    Saia, Francesco
    Napodano, Massimo
    Frigo, Anna Chiara
    Agostoni, Pierfrancesco
    Mojoli, Marco
    Fraccaro, Chiara
    Ciuca, Cristina
    Presbitero, Patrizia
    Moretti, Claudio
    D'Ascenzo, Fabrizio
    Tarantini, Giuseppe
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (06): : 810 - 815
  • [35] Comparison of balloon-expandable vs. self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration
    Vlastra, Wieneke
    Chandrasekhar, Jaya
    Munoz-Garcia, Antonio J.
    Tchetche, Didier
    de Brito, Fabio S., Jr.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    D'Onofrio, Augusto
    Ribichini, Flavio
    Baan, Jan
    Tijssen, Jan G. P.
    Trillo-Nouche, Ramiro
    Dumonteil, Nicolas
    Abizaid, Alexandre
    Sartori, Samantha
    D'Errigo, Paola
    Tarantini, Giuseppe
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    del Valle, Raquel
    Modine, Thomas
    Dangas, George
    Mehran, Roxana
    Piek, Jan J.
    Delewi, Ronak
    EUROPEAN HEART JOURNAL, 2019, 40 (05) : 456 - 465
  • [36] Late Outcomes After Transcatheter Aortic Valve Implantation with Balloon-Versus Self-Expandable Valves Meta-Analysis of Reconstructed Time-To-Event Data
    Jacquemyn, Xander
    Van den Eynde, Jef
    Caldonazo, Tulio
    Brown, James A.
    Dokollari, Aleksander
    Serna-Gallegos, Derek
    Clavel, Marie-Annick
    Pibarot, Philippe
    Sultan, Ibrahim
    Sa, Michel Pompeu
    CARDIOLOGY CLINICS, 2024, 42 (03) : 373 - 387
  • [37] Balloon-versus self-expandable transcatheter aortic valve implantation in small aortic annuli: a meta-analysis of randomized and propensity studies
    Baudo, Massimo
    Sicouri, Serge
    Yamashita, Yoshiyuki
    Magouliotis, Dimitrios
    Cabrucci, Francesco
    Carnila, Sarah
    Ramlawi, Basel
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2025,
  • [38] Comparison of the effects of pre-dilatation with conventional versus larger balloon sizes on clinical outcomes in transcatheter aortic valve implantation with self-expandable valves
    Takahashi, N.
    Doi, S.
    Nishio, R.
    Iwata, H.
    Okazaki, S.
    Higuchi, R.
    Takamisawa, I
    Saji, M.
    Sato, K.
    Tamura, H.
    Yokoyama, H.
    Tobaru, T.
    Takanashi, S.
    Tabata, M.
    Minamino, T.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [39] Reply on Evaluation of Acquired Thrombocytopenia According to the Balloon-Expandable Versus Self-Expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement
    Horna, Stine
    Pollari, Francesco
    Fischlein, Theodor
    ANGIOLOGY, 2021, 72 (03) : 295 - 296
  • [40] Dosis non fecit venerum-Is contrast medium dosage a true predictor of acute kidney injury following transcatheter aortic valve implantation? Data from the VIenna CardioThOracic Aortic Valve RegistrY (VICTORY)
    Valach, F.
    Polat, E.
    Koschutnik, M.
    Santer, D.
    Wallner, S.
    Adlbrecht, C.
    Delle Karth, G.
    Grabenwoeger, M.
    Mach, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 154 - 154