Visual performance and contrast sensitivity after phacoemulsification with implantation of aspheric foldable intraocular lenses

被引:33
|
作者
Nabh, Ravi [1 ]
Ram, Jagat [1 ]
Pandav, Surinder Singh [1 ]
Gupta, Amit [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Ophthalmol, Adv Eye Ctr, Chandigarh 160012, India
来源
关键词
HIGHER-ORDER ABERRATIONS; OPTICAL ABERRATIONS; PHOTOREFRACTIVE KERATECTOMY; SPHERICAL-ABERRATION; CORNEAL ABERRATIONS; OCULAR ABERRATIONS; WAVE ABERRATIONS; CATARACT-SURGERY; HUMAN EYE; VISION;
D O I
10.1016/j.jcrs.2008.10.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual performance after phacoemulsification with implantation of an aspheric intraocular lens (IOL). SETTING: Tertiary eyecare center in north India. METHODS: This prospective study comprised patients with visually significant age-related cataract having clear corneal phacoemulsification with implantation of 1 of 3 types of aspheric IOLs. Twelve weeks postoperatively, visual acuity and contrast sensitivity were recorded. Wavefront analysis was performed with the Optical Path Difference scanner. All patients completed a questionnaire on subjective quality of vision. Main outcome measures were best corrected visual acuity (BCVA), contrast sensitivity, visual function score, and patient satisfaction. RESULTS: Of the 130 eyes (130 patients), a Tecnis Z9003 IOL was implanted in 43 eyes, an AcrySof SN60WF IOL in 41 eyes, and an Akreos Adapt AD IOL in 46 eyes. Contrast sensitivity and BCVA were similar between groups. With 4.0 mm, 5.0 mm, and 6.0 mm pupil diameters, the mean spherical aberrations were significantly less with AcrySof SN60WF and Akreos Adapt AO IOLs than with the Tecnis Z9003 IOL. There were no significant differences in total higher-order root-mean-square (RMS) values between IOLs. Visual performance scores with the 3 IOLs were comparable. CONCLUSIONS: All 3 aspheric IOLs significantly decreased positive spherical ocular aberration after phacoemulsification and may induce negative spherical aberration. However, there was no significant difference in total higher-order RMS values between the IOLs. The 3 IOL models provided comparable contrast sensitivity and visual performance.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 50 条
  • [41] Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison
    Pan-Pan Ye
    Xia Li
    Ke Yao
    International Journal of Ophthalmology, 2013, (03) : 300 - 306
  • [42] Visual function after implantation of a diffractive aspheric trifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega Cueto, Luis
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) : 405 - 411
  • [43] Clinical Outcomes After Phacoemulsification With Implantation of Trifocal and Toric Trifocal Intraocular Lenses
    Eldanasoury, Alaa
    Tolees, Sherif
    Bains, Harkaran S.
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (06) : 372 - 379
  • [44] Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses:a meta-analysis
    Jian-Ping Liu
    Fan Zhang
    Jiang-Yue Zhao
    Li-Wei Ma
    Jin-Song Zhang
    International Journal of Ophthalmology, 2013, (05) : 690 - 695
  • [45] Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses: a meta-analysis
    Liu, Jian-Ping
    Zhang, Fan
    Zhao, Jiang-Yue
    Ma, Li-Wei
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (05) : 690 - 695
  • [46] Imaging performance of spherical and aspheric intraocular lenses
    Werner, W
    Roth, EH
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 214 (04) : 246 - 250
  • [47] Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a+3.0 D addition
    Kohnen, Thomas
    Nuijts, Rudy
    Levy, Pierre
    Haefliger, Eduard
    Alfonso, Jose F.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2062 - 2069
  • [48] Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation
    Pereira, FAS
    Cronemberger, S
    OPHTHALMOLOGY, 2003, 110 (09) : 1799 - 1806
  • [49] Intraocular pressure increase after phacoemulsification and foldable silicone lens implantation using Healon GV®
    Mastropasqua, L
    Carpineto, L
    Ciancaglini, M
    Falconio, G
    Della Loggia, G
    Gallenga, PE
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1997, 75 : 59 - 60
  • [50] Depth of focus after implantation of spherical or aspheric intraocular lenses in hyperopic and emmetropic patients
    Steinwender, Gernot
    Strini, Sanja
    Glatz, Wilfried
    Schwantzer, Gerold
    Vidic, Bertram
    Findl, Oliver
    Wedrich, Andreas
    Ardjomand, Navid
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (11): : 1413 - 1419