Visual performance and contrast sensitivity after phacoemulsification with implantation of aspheric foldable intraocular lenses

被引:33
|
作者
Nabh, Ravi [1 ]
Ram, Jagat [1 ]
Pandav, Surinder Singh [1 ]
Gupta, Amit [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Ophthalmol, Adv Eye Ctr, Chandigarh 160012, India
来源
关键词
HIGHER-ORDER ABERRATIONS; OPTICAL ABERRATIONS; PHOTOREFRACTIVE KERATECTOMY; SPHERICAL-ABERRATION; CORNEAL ABERRATIONS; OCULAR ABERRATIONS; WAVE ABERRATIONS; CATARACT-SURGERY; HUMAN EYE; VISION;
D O I
10.1016/j.jcrs.2008.10.043
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual performance after phacoemulsification with implantation of an aspheric intraocular lens (IOL). SETTING: Tertiary eyecare center in north India. METHODS: This prospective study comprised patients with visually significant age-related cataract having clear corneal phacoemulsification with implantation of 1 of 3 types of aspheric IOLs. Twelve weeks postoperatively, visual acuity and contrast sensitivity were recorded. Wavefront analysis was performed with the Optical Path Difference scanner. All patients completed a questionnaire on subjective quality of vision. Main outcome measures were best corrected visual acuity (BCVA), contrast sensitivity, visual function score, and patient satisfaction. RESULTS: Of the 130 eyes (130 patients), a Tecnis Z9003 IOL was implanted in 43 eyes, an AcrySof SN60WF IOL in 41 eyes, and an Akreos Adapt AD IOL in 46 eyes. Contrast sensitivity and BCVA were similar between groups. With 4.0 mm, 5.0 mm, and 6.0 mm pupil diameters, the mean spherical aberrations were significantly less with AcrySof SN60WF and Akreos Adapt AO IOLs than with the Tecnis Z9003 IOL. There were no significant differences in total higher-order root-mean-square (RMS) values between IOLs. Visual performance scores with the 3 IOLs were comparable. CONCLUSIONS: All 3 aspheric IOLs significantly decreased positive spherical ocular aberration after phacoemulsification and may induce negative spherical aberration. However, there was no significant difference in total higher-order RMS values between the IOLs. The 3 IOL models provided comparable contrast sensitivity and visual performance.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 50 条
  • [21] Wavefront analysis and contrast sensitivity comparison between spheric and aspheric intraocular lenses
    Hida, Wilson Takashi
    Yamane, Iris de Souza
    Pimenta Motta, Antonio Francisco
    Silva, Marcel Tadeu
    Alves, Emerson
    Jose Junior, Newton Kara
    Nakano, Celso Takashi
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2008, 67 (03) : 119 - 124
  • [22] Contrast sensitivity in patients with aspheric profiles in light-adjustable intraocular lenses
    Villegas, Eloy A.
    Hervella, Lucia
    Caballero, Jose
    Haller, Matthew
    Benito, Antonio
    Maria Marin, Jose
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [23] Contrast visual acuity after multifocal intraocular lens implantation: aspheric versus spherical design
    Jun-Hua Li
    Yi-Fan Feng
    Yun-E Zhao
    Yin-Ying Zhao
    Lei Lin
    International Journal of Ophthalmology, 2014, (01) : 100 - 103
  • [24] Comparison of Optical Aberrations and Contrast Sensitivity Between Aspheric and Spherical Intraocular Lenses
    Morales, Eduardo L.
    Rocha, Karolinne M.
    Chalita, Maria Regina
    Nose, Walton
    Avila, Marcos P.
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) : 723 - 728
  • [25] Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses - Prospective evaluation
    Kershner, RM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (09): : 1684 - 1694
  • [26] CONTRAST SENSITIVITY POSTPHACOEMULSIFICATION AND INTRAOCULAR LENSES IMPLANTATION IN HISPANIC POPULATION
    DELAFUENTE, MA
    APARICIO, A
    DURAN, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S793 - S793
  • [27] Visual function after implantation of an aspheric bifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Amhaz, Hussein
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05): : 885 - 892
  • [28] Visual performance of 2 aspheric toric intraocular lenses: Comparative study
    Scialdone, Antonio
    De Gaetano, Francesco
    Monaco, Gaspare
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06): : 906 - 914
  • [29] Course of postoperative inflammation after implantation of 4 types of foldable intraocular lenses
    Schauersberger, J
    Kruger, A
    Abela, C
    Müllner-Eidenböck, A
    Petternel, V
    Svolba, G
    Amon, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08): : 1116 - 1120
  • [30] Anterior segment complications after phacoemulsification combined vitrectomy and foldable intraocular lens implantation
    Zheng, Qin-Xiang
    Wu, Rong-Han
    Zhang, Yuan-Ping
    Xu, Ming
    Li, Wen-Sheng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2010, 3 (03): : 249 - 254