Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams

被引:9
|
作者
Gul, Attia [1 ,2 ]
Fukuda, Shigekazu [1 ]
Mizuno, Hideyuki [1 ]
Taku, Nakaji [1 ]
Kakakhel, M. Basim [2 ]
Mirza, Sikander M. [2 ]
机构
[1] QST Hosp, Natl Inst Quantum & Radiol Sci & Technol, Chiba, Japan
[2] Pakistan Inst Engn & Appl Sci PIEAS, Dept Phys & Appl Math, Islamabad, Pakistan
来源
关键词
correction factors; field output factors; PTW31023; RAZOR diode; RAZOR nano chamber; small field dosimetry; stereotactic field diode; RADIOSURGERY BEAMS; SILICON DIODE; PROTOTYPE; CHAMBER;
D O I
10.1002/acm2.13007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study assesses the feasibility of using stereotactic field diode (SFD) as an alternate to gaf chromic films for field output factor (FF) measurement and further evaluating three new detectors for small field dosimetry. Varian 21EX linear accelerator was used to generate 6 and 10 MV beams of nominal square fields ranging from 0.5 x 0.5 cm(2)to 10 x 10 cm(2). One passive (EBT3 films) and five active detectors including IBA RAZOR diode(RD), SFD, RAZOR nanochamber (RNC), pinpoint chamber (PTW31023), and semiflex chamber (PTW31010) were employed. FFs were measured using films and SFD while beam profiles and percentage depth dose (PDD) distribution were acquired with active detectors. Polarity (k(pol)) and recombination (k(s)) effects of ion chambers were determined and corrected for output ratio measurement. Correction factors (CF) of RD, RNC, and PTW31023 in axial and radial orientation were also measured. Stereotactic field diode measured FFs have shown good agreement with films (with difference of <1%). RD and RNC measured beam profiles were within 3% deviation from the SFD values. Variation ink(pol)with field size for RNC and PTW31023 was up to 4% and 0.4% (for fields >= 1 x 1 cm(2)), respectively, while variation ink(s)of PTW31023 was <0.2 %. The maximum values of CF have been calculated to be 5.2%, 2.0%, 13.6%, and 25.5% for RD, RNC, PTW31023-axial, and PTW31023-radial respectively. This study concludes that SFD with appropriate CFs as given in TRS 483 may be used for measuring FFs as an alternate to EBT3 films. Whereas RD and RNC may be used for beam profile and PDD measurement in small fields. Considering the limit of usability of 2%, RNC may be used without CF for FF measurement in the smallfields investigated in this study.
引用
收藏
页码:23 / 36
页数:14
相关论文
共 33 条
  • [1] Determination of small field output factors in 6 and 10 MV flattening filter free photon beams using various detectors
    Masanga, W.
    Tangboonduangjit, P.
    Khamfongkhruea, C.
    Tannanonta, C.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [2] Correction factors for diode and diamond detectors in the measurement of small field output factors, using film dosimetry as reference
    Osman, Alexander F. I.
    Jalbout, Wassim
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):
  • [3] Study of Response of Plastic Scintillation Detectors in Small Field 6 MV Photon Beams
    Wang, L.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Monte Carlo study on electron contamination and output factors of small field dosimetry in 6 MV photon beam
    Yani, Sitti
    Dirgayussa, I. Gde Eka
    Rhani, Mohamad Fahdillah
    Soh, Roger C. X.
    Haryanto, Freddy
    Arif, Idam
    [J]. SMART SCIENCE, 2016, 4 (02): : 87 - 94
  • [5] Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: A PENELOPE Monte Carlo study
    Benmakhlouf, Hamza
    Sempau, Josep
    Andreo, Pedro
    [J]. MEDICAL PHYSICS, 2014, 41 (04)
  • [6] Monte Carlo calculated output correction factors for nine small field detectors in Varian Clinac iX 6 MV photon beams
    Benmakhlouf, H.
    Sempau, J.
    Andreo, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S201 - S202
  • [7] COMPARISON OF DIODE, DIAMOND AND SCINTILLATION DETECTORS FOR THE MEASUREMENT OF SMALL FIELD OUTPUT FACTORS
    Warrener, K.
    Ralston, A.
    Liu, P.
    McKenzie, D.
    Suchowerska, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S147 - S147
  • [8] Measurement of the small field output factors for 10 MV photon beam using IAEA TRS-483 dosimetry protocol and implementation in Eclipse TPS commissioning
    Kinhikar, Rajesh
    Saini, Vinay
    Upreti, Ritu Raj
    Kale, Shrikant
    Sutar, Avadhoot
    Tambe, Chandrashekhar
    Kadam, Sudarshan
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [9] Relative biological damage in and out of field of 6, 10 and 18 MV clinical photon beams
    Ezzati, A. O.
    [J]. EUROPEAN PHYSICAL JOURNAL PLUS, 2016, 131 (08):
  • [10] Relative biological damage in and out of field of 6, 10 and 18 MV clinical photon beams
    A. O. Ezzati
    [J]. The European Physical Journal Plus, 131