KSTAR Magnetic Field Measurement During the Commissioning and Remanent Field Evaluation

被引:4
|
作者
Yonekawa, Hirofumi [1 ]
Kim, Y. O. [1 ]
Lee, Hyun Jung [1 ]
Yoon, S. W. [1 ]
Hahn, S. H. [1 ]
Lee, K. S. [1 ]
Lee, D. K. [1 ]
Park, Soo Hwan [1 ]
Chu, Yong [1 ]
Bang, E. N. [1 ]
Park, K. R. [1 ]
Oh, Y. K. [1 ]
Bak, J. S. [1 ]
Leuer, J. A. [2 ]
机构
[1] Natl Fus Res Inst, Taejon 305333, South Korea
[2] Gen Atom Co, San Diego, CA USA
关键词
Incoloy; 908; Nb3Sn; remanent magnetic field; superconducting magnet coil; CS MODEL COIL;
D O I
10.1109/TASC.2009.2018486
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in-situ measurement of the magnetic field generated by the assembled superconducting magnet coils was held by using precision Hall sensors during the commissioning of the Korea Superconducting Tokamak Advanced Research ( KSTAR) device. This was done in order to investigate the magnetic influence of Incoloy 908, which is the jacket material for the cable-in-conduit conductors (CICCs) of the Nb3Sn coils. After the PF coils were discharged from 1 kA the vertical remanent field at the plasma center was more than 10 G, while the TF coils were not energized. The vertical magnetic field generated by the PF coils had a discrepancy of up to 50 G between measurement and the calculation assuming no magnetic influence of Incoloy 908. Thus, non-negligible ferromagnetism was identified and attributed to Incoloy 908. In contrast, most of the hysteresis observed in the magnetic measurements was eliminated when the Incoloy 908 of the TF windings was saturated by the TF coil charging.
引用
收藏
页码:1573 / 1576
页数:4
相关论文
共 50 条
  • [41] Remanent magnetic field distribution in Bi-2223/Ag superconducting tape
    Thamizhavel, A
    Sugano, M
    Fukuda, N
    Sakai, A
    Osamura, K
    ADVANCES IN SUPERCONDUCTIVITY XII, 2000, : 673 - 675
  • [42] Effect of magnetic field direction on the remanent resistance levels and vortex chirality of a multilayered magnetic ring
    Nam, Chunghee
    Ng, B. G.
    Castano, F. J.
    Ross, C. A.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (03)
  • [43] Development of a Magnetic Field Probe for Near-Field Measurement
    Loon, Goh Kai
    Baharuddin, Mohd Hafiz
    JURNAL KEJURUTERAAN, 2021, 33 (04): : 853 - 861
  • [44] Radial electric field measurement in a tokamak with magnetic field ripple
    Trier, E.
    Eriksson, L. -G.
    Hennequin, P.
    Fenzi, C.
    Bourdelle, C.
    Falchetto, G.
    Garbet, X.
    Aniel, T.
    Clairet, F.
    Sabot, R.
    NUCLEAR FUSION, 2008, 48 (09)
  • [45] Measurement of magnetic permeability in a constant field
    Dyakin, VV
    Umergalina, OV
    Sandovskii, VA
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1996, 32 (02) : 103 - 111
  • [46] ACHIEVEMENT AND MEASUREMENT OF THE ORIC MAGNETIC FIELD
    HUDSON, ED
    LORD, RS
    MARSHALL, MB
    SMITH, WR
    RICHARDSON, EG
    NUCLEAR INSTRUMENTS & METHODS, 1962, 18 (NOV): : 159 - 169
  • [47] MEASUREMENT OF PLASMA PARAMETERS IN A MAGNETIC FIELD
    DUBOVOI, LV
    PONOMARENKO, AG
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1962, 6 (11): : 947 - &
  • [48] MAGNETIC FIELD MEASUREMENT USING ULTRASONICS
    RADUS, RJ
    JOURNAL OF APPLIED PHYSICS, 1960, 31 (05) : S186 - S187
  • [49] MAGNETIC FIELD MEASUREMENT FOR ELECTROMAGNETIC FLOWMETERS
    ROSE, GA
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 109 - &
  • [50] Measurement of radio frequency magnetic field
    Bartusek, K.
    Gescheidtova, E.
    PIERS 2007 BEIJING: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, PTS I AND II, PROCEEDINGS, 2007, : 182 - +