KSTAR Magnetic Field Measurement During the Commissioning and Remanent Field Evaluation

被引:4
|
作者
Yonekawa, Hirofumi [1 ]
Kim, Y. O. [1 ]
Lee, Hyun Jung [1 ]
Yoon, S. W. [1 ]
Hahn, S. H. [1 ]
Lee, K. S. [1 ]
Lee, D. K. [1 ]
Park, Soo Hwan [1 ]
Chu, Yong [1 ]
Bang, E. N. [1 ]
Park, K. R. [1 ]
Oh, Y. K. [1 ]
Bak, J. S. [1 ]
Leuer, J. A. [2 ]
机构
[1] Natl Fus Res Inst, Taejon 305333, South Korea
[2] Gen Atom Co, San Diego, CA USA
关键词
Incoloy; 908; Nb3Sn; remanent magnetic field; superconducting magnet coil; CS MODEL COIL;
D O I
10.1109/TASC.2009.2018486
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An in-situ measurement of the magnetic field generated by the assembled superconducting magnet coils was held by using precision Hall sensors during the commissioning of the Korea Superconducting Tokamak Advanced Research ( KSTAR) device. This was done in order to investigate the magnetic influence of Incoloy 908, which is the jacket material for the cable-in-conduit conductors (CICCs) of the Nb3Sn coils. After the PF coils were discharged from 1 kA the vertical remanent field at the plasma center was more than 10 G, while the TF coils were not energized. The vertical magnetic field generated by the PF coils had a discrepancy of up to 50 G between measurement and the calculation assuming no magnetic influence of Incoloy 908. Thus, non-negligible ferromagnetism was identified and attributed to Incoloy 908. In contrast, most of the hysteresis observed in the magnetic measurements was eliminated when the Incoloy 908 of the TF windings was saturated by the TF coil charging.
引用
收藏
页码:1573 / 1576
页数:4
相关论文
共 50 条
  • [21] ANOMALOUS HYSTERESIS OF THE REMANENT MAGNETIZATION FIELD AND OF ITS GRADIENT IN MAGNETIZING A FERROMAGNETIC WITH A PULSED MAGNETIC-FIELD
    MELGUI, MA
    KRATIROV, VB
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1986, 22 (12): : 854 - 859
  • [22] MEASUREMENT OF MAGNETIC FIELD CONTOURS
    FREEMAN, R
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1961, 38 (08): : 318 - &
  • [23] MEASUREMENT OF MAGNETIC FIELD GRADIENTS
    FRAZER, JF
    HOFMANN, JA
    LIVINGSTON, MS
    VASH, AM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (05): : 475 - 476
  • [24] Measurement of magnetic field in dentistry
    Bukovic, D
    Carek, V
    Durek, D
    Kuna, T
    Keros, J
    COLLEGIUM ANTROPOLOGICUM, 2000, 24 : 85 - 89
  • [25] Measurement of the CMS magnetic field
    Klyukhin, V. I.
    Ball, A.
    Bergsma, F.
    Campi, D.
    Cure, B.
    Gaddi, A.
    Gerwig, H.
    Herve, A.
    Korienek, J.
    Linde, F.
    Lindenmeyer, C.
    Loveless, R.
    Mulders, M.
    Nebel, T.
    Smith, R. P.
    Stickland, D.
    Teafoe, G.
    Veillet, L.
    Zimmerman, J. K.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 395 - 398
  • [26] Magnetic field measurement system
    Kulesza, Joe
    Johnson, Enic
    Lyndaker, Aaron
    Deyhim, Alex
    Waterman, Dave
    Blomqvist, K. Ingvar
    Hunter Dunn, Jonathan
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 408 - +
  • [27] Absolute magnetic field measurement
    Auer, H
    ANNALEN DER PHYSIK, 1933, 18 (06) : 613 - 624
  • [28] The measurement of magnetic field distortion
    Rankine, AO
    PROCEEDINGS OF THE PHYSICAL SOCIETY, 1934, 46 : 1 - 15
  • [29] MEASUREMENT OF INTERSTELLAR MAGNETIC FIELD
    SMITH, FG
    NATURE, 1968, 218 (5139) : 325 - &
  • [30] Measurement of gradient magnetic field
    Smutny, T
    Kafka, V
    Bartusek, K
    Fiala, P
    Proceedings of the 4th WSEAS International Conference on Applications of Electrical Engineering, 2005, : 451 - 453