A patient-specific finite element model of the smoker's lung during breathing

被引:2
|
作者
Hasani, Mojtaba [1 ]
Razaghi, Reza [2 ]
Hassani, Kamran [3 ]
Rahmati, Seyed Mohammadali [4 ]
Tehrani, Pedram [5 ]
Karimi, Alireza [6 ]
机构
[1] Univ Isfahan, Dept Biomed Engn, Fac Engn, Esfahan, Iran
[2] Basir Eye Hlth Res Ctr, Tehran, Iran
[3] Islamic Azad Univ, Sci & Res Branch, Dept Biomech, Tehran, Iran
[4] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
[5] Islamic Azad Univ, Cent Tehran Branch, Dept Mech Engn, Tehran, Iran
[6] Univ Alabama Birmingham, Dept Ophthalmol & Visual Sci, Birmingham, AL 35294 USA
关键词
Lung biomechanics; Smoking; finite element method; rib cage; Injury; Stress and deformation;
D O I
10.1177/0954408920974814
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Lungs expand during breathing through increasing the space in the chest cavity. The mechanical properties of the lung play a pivotal role for space, which provides during breathing. Smoking via chronic obstructive pulmonary disease (COPD) can affect this mechanical function through the alteration of the mechanical properties of the lung tissue. Recently our group performed an experimental study to measure the axial and transversal mechanical properties of the human healthy and smokers' lung tissues (Karimi et al., Tech Health Care 2018). Our results revealed a higher stiffness for the smokers' lung tissues compared to the healthy ones. Here, we aimed to calculate the stresses, pressures, deformations, and kinetic energies in the healthy and smokers' lung tissues during breathing in interaction with the ribs and sternum. To do that, a patient-specific finite element (FE) model of the human lung was established and numerically subjected to an inhale-exhale pressure phase. The FE results revealed a higher pressure and a lower deformation in the smoking lung tissue compared to the healthy one. In addition, the stiffer smoking lung exerted a higher pressure and deformation in the sternum and ribs compared to the healthy lung. Furthermore, the smoking lung displayed a lower kinetic energy compared to the healthy lung and as a result, it transferred a higher amount of energy to the bones, which might increase the chance of bone remodeling and/or fracture during, e.g., coughing. These results have implications for not only understanding of the stresses and deformations induce in the lung tissues among the healthy and smokers during breathing but also for providing a preliminary information for the medical and biomechanical experts to have an assessment of the amount of injury occurs to the lung because of smoking.
引用
收藏
页码:879 / 886
页数:8
相关论文
共 50 条
  • [31] An anatomically based patient-specific finite element model of patella articulation: towards a diagnostic tool
    Fernandez, JW
    Hunter, PJ
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2005, 4 (01) : 20 - 38
  • [32] Patient-Specific Immersed Finite Element-Difference Model of Transcatheter Aortic Valve Replacement
    Brown, Jordan A.
    Lee, Jae H.
    Smith, Margaret Anne
    Wells, David R.
    Barrett, Aaron
    Puelz, Charles
    Vavalle, John P.
    Griffith, Boyce E.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (01) : 103 - 116
  • [33] An anatomically based patient-specific finite element model of patella articulation: towards a diagnostic tool
    J. W. Fernandez
    P. J. Hunter
    [J]. Biomechanics and Modeling in Mechanobiology, 2005, 4 : 20 - 38
  • [34] Towards Patient-Specific Finite-Element Simulation of MitralClip Procedure
    Mansi, T.
    Voigt, I.
    Mengue, E. Assoumou
    Ionasec, R.
    Georgescu, B.
    Noack, T.
    Seeburger, J.
    Comaniciu, D.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 452 - +
  • [35] Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation
    Thuy Pham
    Fanwei Kong
    Caitlin Martin
    Qian Wang
    Charles Primiano
    Raymond McKay
    John Elefteriades
    Wei Sun
    [J]. Cardiovascular Engineering and Technology, 2017, 8 : 3 - 16
  • [36] Patient-Specific Finite Element Analysis of Ascending Thoracic Aortic Aneurysm
    Wisneski, Andrew D.
    Mookhoek, Aart
    Chitsaz, Sam
    Hope, Michael D.
    Guccione, Julius M.
    Ge, Liang
    Tseng, Elaine E.
    [J]. JOURNAL OF HEART VALVE DISEASE, 2014, 23 (06): : 765 - 772
  • [37] Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design
    Rodrigues, Monise de Paula
    Ferreira Soares, Priscilla Barbosa
    Correia Miranda Valdivia, Andrea Dollores
    Pessoa, Roberto Sales
    Verissimo, Crisnicaw
    Versluis, Antheunis
    Soares, Carlos Jose
    [J]. JOURNAL OF ENDODONTICS, 2017, 43 (09) : 1539 - 1544
  • [38] Finite element analysis of patient-specific additive-manufactured implants
    Namvar, Arman
    Lozanovski, Bill
    Downing, David
    Williamson, Tom
    Kastrati, Endri
    Shidid, Darpan
    Hill, David
    Buehner, Ulrich
    Ryan, Stewart
    Choong, Peter F.
    Sanaei, Reza
    Leary, Martin
    Brandt, Milan
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [39] Finite Element Modelling of Stent Deployment in a Patient-specific Coronary Artery
    He, Ran
    Zhao, Liguo
    Silberschmidt, Vadim V.
    Liu, Yang
    Vogt, Felix
    [J]. INTERNATIONAL CONFERENCE ON STENTS: MATERIALS, MECHANICS AND MANUFACTURING (ICS3M 2019), 2019, 15 : 28 - 32
  • [40] Finite Element Analysis of Patient-Specific Femur Bone for Synthetic Biomaterials
    Khare, Navneet
    Sharma, Gorang
    Modi, Yashwant Kumar
    [J]. ADVANCES IN MECHANICAL ENGINEERING, ICRIDME 2018, 2020, : 649 - 659