Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design

被引:23
|
作者
Rodrigues, Monise de Paula [1 ]
Ferreira Soares, Priscilla Barbosa [2 ]
Correia Miranda Valdivia, Andrea Dollores [1 ]
Pessoa, Roberto Sales [1 ]
Verissimo, Crisnicaw [3 ]
Versluis, Antheunis [4 ]
Soares, Carlos Jose [1 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Sch Dent, Dept Periodontol & Implantol, Uberlandia, MG, Brazil
[3] Univ Uberaba, Sch Dent, Uberaba, MG, Brazil
[4] Univ Tennessee, Hlth Sci Ctr, Dept Biosci Res, Coll Dent, Memphis, TN USA
关键词
Endodontically treated teeth; fiber post; finite element analysis; patient-specific model; stress; REMAINING CORONAL DENTIN; STRESS-DISTRIBUTION; BIOMECHANICAL BEHAVIOR; FRACTURE-RESISTANCE; ANTERIOR TEETH; CROWN; BONE; ROOT; PERFORMANCE; FAILURE;
D O I
10.1016/j.joen.2017.04.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: A ferrule on anterior endodontic-treated teeth has been evaluated using clinical trials, in vitro tests, and finite element analysis (FEA). The patient specific FEA with a nonuniform ferrule and nonlinear contact biting load associated with clinical validation can be used to predict failure. Methods: A patient was selected with both maxillary central incisors with different ferrule designs who received endodontic treatment and restoration using a fiber post, composite core, and computer aided design and computer aided manufacturing lithium disilicate ceramic crowns. Strain gauges were attached to the buccal surfaces of both teeth to record ceramic strain during bite force recording for FEA validation. Cone-beam computed tomographic imaging was performed, and the Digital Imaging and Communication in Medicine files were exported to Mimics, 3-Matic (Materialise, Leuven, Belgium) and Patran (MSC Software, Santa Ana, CA) software to create a patient-specific FEA model. Bite load was applied using contact load applied by antagonist teeth (155 N). Mechanical properties were obtained from the literature. Modified von Mises equivalent stress was used for stress evaluation. Results: Stresses on the dentin and fiber post on the left incisor, which had a nonuniform ferrule, were higher compared with the right incisor. The strain values recorded for the right central incisor (strain gauge =79.9 +/- 3.8 mu S and FEA = 69.5 mu S) and the left central incisor (strain gauge = 83.5 +/- 5.3 mu S and FEA = 73.9 mu S) validate the FEA analysis. Conclusions: FEA was validated with in vivo strain values measured at the buccal crown surfaces, supporting that the stress levels were realistic for investigation of the clinical performance of fiber posts. Maintaining a uniform ferrule was more favorable than a localized higher ferrule.
引用
收藏
页码:1539 / 1544
页数:6
相关论文
共 50 条
  • [1] Design and Finite Element Analysis of Patient-Specific Total Temporomandibular Joint Implants
    Ingawale, Shirish M.
    Goswami, Tarun
    [J]. MATERIALS, 2022, 15 (12)
  • [2] Evaluation of Patient-Specific Cranial Implant Design Using Finite Element Analysis
    Huys, Stijn E. F.
    Van Gysel, Anke
    Mommaerts, Maurice Y.
    Vander Sloten, Jos
    [J]. WORLD NEUROSURGERY, 2021, 148 : 198 - 204
  • [3] Patient-specific finite element analysis of popliteal stenting
    Conti, Michele
    Marconi, Michele
    Campanile, Giulia
    Reali, Alessandro
    Adami, Daniele
    Berchiolli, Raffaella
    Auricchio, Ferdinando
    [J]. MECCANICA, 2017, 52 (03) : 633 - 644
  • [4] Patient-specific finite element analysis of popliteal stenting
    Michele Conti
    Michele Marconi
    Giulia Campanile
    Alessandro Reali
    Daniele Adami
    Raffaella Berchiolli
    Ferdinando Auricchio
    [J]. Meccanica, 2017, 52 : 633 - 644
  • [5] Patient-specific finite element analysis of ascending aorta aneurysms
    Martin, Caitlin
    Sun, Wei
    Elefteriades, John
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2015, 308 (10): : H1306 - H1316
  • [6] PATIENT-SPECIFIC FINITE ELEMENT ANALYSIS OF CAROTID ARTERY STENTING
    Conti, Michele
    Auricchio, Ferdinando
    De Santis, Gianluca
    De Beule, Matthieu
    Verhegghe, Benedict
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 561 - 562
  • [7] Patient-specific finite element modeling of bones
    Poelert, Sander
    Valstar, Edward
    Weinans, Harrie
    Zadpoor, Amir A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H4) : 464 - 478
  • [8] Patient-Specific Finite Element Analysis of Ascending Thoracic Aortic Aneurysm
    Wisneski, Andrew D.
    Mookhoek, Aart
    Chitsaz, Sam
    Hope, Michael D.
    Guccione, Julius M.
    Ge, Liang
    Tseng, Elaine E.
    [J]. JOURNAL OF HEART VALVE DISEASE, 2014, 23 (06): : 765 - 772
  • [9] Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation
    Thuy Pham
    Fanwei Kong
    Caitlin Martin
    Qian Wang
    Charles Primiano
    Raymond McKay
    John Elefteriades
    Wei Sun
    [J]. Cardiovascular Engineering and Technology, 2017, 8 : 3 - 16
  • [10] Finite element analysis of patient-specific additive-manufactured implants
    Namvar, Arman
    Lozanovski, Bill
    Downing, David
    Williamson, Tom
    Kastrati, Endri
    Shidid, Darpan
    Hill, David
    Buehner, Ulrich
    Ryan, Stewart
    Choong, Peter F.
    Sanaei, Reza
    Leary, Martin
    Brandt, Milan
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12