Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design

被引:23
|
作者
Rodrigues, Monise de Paula [1 ]
Ferreira Soares, Priscilla Barbosa [2 ]
Correia Miranda Valdivia, Andrea Dollores [1 ]
Pessoa, Roberto Sales [1 ]
Verissimo, Crisnicaw [3 ]
Versluis, Antheunis [4 ]
Soares, Carlos Jose [1 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Sch Dent, Dept Periodontol & Implantol, Uberlandia, MG, Brazil
[3] Univ Uberaba, Sch Dent, Uberaba, MG, Brazil
[4] Univ Tennessee, Hlth Sci Ctr, Dept Biosci Res, Coll Dent, Memphis, TN USA
关键词
Endodontically treated teeth; fiber post; finite element analysis; patient-specific model; stress; REMAINING CORONAL DENTIN; STRESS-DISTRIBUTION; BIOMECHANICAL BEHAVIOR; FRACTURE-RESISTANCE; ANTERIOR TEETH; CROWN; BONE; ROOT; PERFORMANCE; FAILURE;
D O I
10.1016/j.joen.2017.04.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: A ferrule on anterior endodontic-treated teeth has been evaluated using clinical trials, in vitro tests, and finite element analysis (FEA). The patient specific FEA with a nonuniform ferrule and nonlinear contact biting load associated with clinical validation can be used to predict failure. Methods: A patient was selected with both maxillary central incisors with different ferrule designs who received endodontic treatment and restoration using a fiber post, composite core, and computer aided design and computer aided manufacturing lithium disilicate ceramic crowns. Strain gauges were attached to the buccal surfaces of both teeth to record ceramic strain during bite force recording for FEA validation. Cone-beam computed tomographic imaging was performed, and the Digital Imaging and Communication in Medicine files were exported to Mimics, 3-Matic (Materialise, Leuven, Belgium) and Patran (MSC Software, Santa Ana, CA) software to create a patient-specific FEA model. Bite load was applied using contact load applied by antagonist teeth (155 N). Mechanical properties were obtained from the literature. Modified von Mises equivalent stress was used for stress evaluation. Results: Stresses on the dentin and fiber post on the left incisor, which had a nonuniform ferrule, were higher compared with the right incisor. The strain values recorded for the right central incisor (strain gauge =79.9 +/- 3.8 mu S and FEA = 69.5 mu S) and the left central incisor (strain gauge = 83.5 +/- 5.3 mu S and FEA = 73.9 mu S) validate the FEA analysis. Conclusions: FEA was validated with in vivo strain values measured at the buccal crown surfaces, supporting that the stress levels were realistic for investigation of the clinical performance of fiber posts. Maintaining a uniform ferrule was more favorable than a localized higher ferrule.
引用
收藏
页码:1539 / 1544
页数:6
相关论文
共 50 条
  • [21] Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis
    Koh, Y-G
    Park, K-M
    Lee, H-Y
    Kang, K-T
    [J]. BONE & JOINT RESEARCH, 2019, 8 (03): : 156 - 164
  • [22] Patient-specific finite element modeling for femoral bone augmentation
    Basafa, Ehsan
    Armiger, Robert S.
    Kutzer, Michael D.
    Belkoff, Stephen M.
    Mears, Simon C.
    Armand, Mehran
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (06) : 860 - 865
  • [23] The first patient-specific finite element model of the rotational atherectomy
    Celi, S.
    Vaghetti, M.
    Palmieri, C.
    Kull, S.
    Marchi, F.
    Berti, S.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 347 - 347
  • [24] Patient-specific finite element model of the hip muscles and bones
    Jolivet, Erwan
    Laredo, Jean-Denis
    Bonneau, Dominique
    Skalli, Wafa
    [J]. EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2009, 18 (01): : 117 - 129
  • [25] Patient-specific Finite Element Model of Coronary Artery Stenting
    Razaghi, Reza
    Karimi, Alireza
    Taheri, Ramezan Ali
    [J]. CURRENT PHARMACEUTICAL DESIGN, 2018, 24 (37) : 4492 - 4502
  • [26] Validation of a finite element model of pediatric patient-specific mandible
    Zhao, LP
    Patel, PK
    Widera, GEO
    Harris, GF
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1831 - 1834
  • [27] Biomechanical Study on the Efficacy of the Periacetabular Osteotomy using Patient-specific Finite Element Analysis
    Lee, Kyung-Jin
    Park, Sung-Jae
    Lee, Sung-Jae
    Naito, Masatoshi
    Kwon, Soon-Yong
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (04) : 823 - 829
  • [28] Patient-specific finite element analysis for assessing hip fracture risk in aging populations
    Chethan, K. N.
    Waldschmidt, Nadine Schmidt Genannt
    Corda, John Valerian
    Shenoy, Satish B.
    Shetty, Sawan
    Keni, Laxmikant G.
    Bhat, Shyamasunder N.
    Nikam, Nishant
    Mihcin, Senay
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
  • [29] Patient-specific finite element analysis of transcatheter aortic valve implantation: a clinical case
    Finotello, A.
    Morganti, S.
    Brambilla, N.
    Bedogni, F.
    Auricchio, F.
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2017, 47 : 110 - 110
  • [30] Patient-specific finite element analysis of carotid artery stenting: a focus on vessel modeling
    Auricchio, F.
    Conti, M.
    Ferrara, A.
    Morganti, S.
    Reali, A.
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2013, 29 (06) : 645 - 664