Quantitative Assessment of the Impact of Geometric Distortions and Their Correction on fMRI Data Analyses

被引:3
|
作者
Abreu, Rodolfo [1 ]
Duarte, Joao Valente [1 ,2 ]
机构
[1] Univ Coimbra, Coimbra Inst Biomed Imaging & Translat Res CIBIT, Inst Nucl Sci Appl Hlth ICNAS, Coimbra, Portugal
[2] Univ Coimbra, Fac Med, Coimbra, Portugal
关键词
fMRI; susceptibility artifact; geometric distortions and correction; B-0 field mapping; neuroimaging; POINT-SPREAD FUNCTION; ECHO-PLANAR IMAGES; PHYSIOLOGICAL NOISE CORRECTION; HIGH-RESOLUTION; SUSCEPTIBILITY ARTIFACTS; BRAIN; ROBUST; EPI; REGISTRATION; DIFFUSION;
D O I
10.3389/fnins.2021.642808
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional magnetic resonance imaging (fMRI) data is typically collected with gradient-echo echo-planar imaging (GE-EPI) sequences, which are particularly prone to the susceptibility artifact as a result of B-0 field inhomogeneity. The component derived from in-plane spin dephasing induces pixel intensity variations and, more critically, geometric distortions. Despite the physical mechanisms underlying the susceptibility artifact being well established, a systematic investigation on the impact of the associated geometric distortions, and the direct comparison of different approaches to tackle them, on fMRI data analyses is missing. Here, we compared two different distortion correction approaches, by acquiring additional: (1) EPI data with reversed phase encoding direction (TOPUP), and (2) standard (and undistorted) GE data at two different echo times (GRE). We first characterized the geometric distortions and the correction approaches based on the estimated Delta B-0 field offset and voxel shift maps, and then conducted three types of analyses on the distorted and corrected fMRI data: (1) registration into structural data, (2) identification of resting-state networks (RSNs), and (3) mapping of task-related brain regions of interest. GRE estimated the largest voxel shifts and more positively impacted the quality of the analyses, in terms of the (significantly lower) cost function of the registration, the (higher) spatial overlap between the RSNs and appropriate templates, and the (significantly higher) sensitivity of the task-related mapping based on the Z-score values of the associated activation maps, although also evident when considering TOPUP. fMRI data should thus be corrected for geometric distortions, with the choice of the approach having a modest, albeit positive, impact on the fMRI analyses.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Objective Assessment of Perceived Geometric Distortions in Viewport Rendering of 360° Images
    Jabar, Falah
    Ascenso, Joao
    Queluz, Maria Paula
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2020, 14 (01) : 49 - 63
  • [32] Assessment of residual MRI geometric distortions on brain and spine stereotactic treatments
    Tamsamani, Karima
    Tournier, Aurelie
    Puiseux, Thomas
    Ken, Soleakhena
    Moreno, Ramiro
    Vieillevigne, Laure
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3818 - S3819
  • [33] Impact of Uncompensated Ionospheric Distortions on MARSIS Data
    Restano, Marco
    Picardi, Giovanni
    Seu, Roberto
    PIERS 2013 STOCKHOLM: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2013, : 1500 - 1504
  • [34] Geometric effects of volume-to-surface mapping of fMRI data
    Keith George Ciantar
    Christine Farrugia
    Paola Galdi
    Kenneth Scerri
    Ting Xu
    Claude J. Bajada
    Brain Structure and Function, 2022, 227 : 2457 - 2464
  • [35] Geometric effects of volume-to-surface mapping of fMRI data
    Ciantar, Keith George
    Farrugia, Christine
    Galdi, Paola
    Scerri, Kenneth
    Xu, Ting
    Bajada, Claude J.
    BRAIN STRUCTURE & FUNCTION, 2022, 227 (07): : 2457 - 2464
  • [36] Correction of geometric distortions in EP images using nonrigid registration to corresponding anatomic images
    Skerl, D
    Pan, SY
    Li, R
    Fitzpatrick, M
    Parks, MH
    Martin, PR
    Morgan, VL
    Dawant, BM
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 58 - 68
  • [37] Joint Estimation and Correction of Geometric Distortions for EPI Functional MRI Using Harmonic Retrieval
    Nguyen, Hien M.
    Sutton, Bradley P.
    Morrison, Robert L., Jr.
    Do, Minh N.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) : 423 - 434
  • [38] The impact of physiological noise correction on fMRI at 7 T
    Hutton, C.
    Josephs, O.
    Stadler, J.
    Featherstone, E.
    Reid, A.
    Speck, O.
    Bernarding, J.
    Weiskopf, N.
    NEUROIMAGE, 2011, 57 (01) : 101 - 112
  • [39] OdorMapComparer: An Application for Quantitative Analyses and Comparisons of fMRI Brain Odor Maps
    Nian Liu
    Fuqiang Xu
    Perry L. Miller
    Gordon M. Shepherd
    Neuroinformatics, 2007, 5 : 105 - 114
  • [40] OdorMapComparer: An application for quantitative analyses and comparisons of fMRI brain odor maps
    Liu, Nian
    Xu, Fuqiang
    Miller, Perry L.
    Shepherd, Gordon M.
    NEUROINFORMATICS, 2007, 5 (02) : 105 - 114