Quantitative Assessment of the Impact of Geometric Distortions and Their Correction on fMRI Data Analyses

被引:3
|
作者
Abreu, Rodolfo [1 ]
Duarte, Joao Valente [1 ,2 ]
机构
[1] Univ Coimbra, Coimbra Inst Biomed Imaging & Translat Res CIBIT, Inst Nucl Sci Appl Hlth ICNAS, Coimbra, Portugal
[2] Univ Coimbra, Fac Med, Coimbra, Portugal
关键词
fMRI; susceptibility artifact; geometric distortions and correction; B-0 field mapping; neuroimaging; POINT-SPREAD FUNCTION; ECHO-PLANAR IMAGES; PHYSIOLOGICAL NOISE CORRECTION; HIGH-RESOLUTION; SUSCEPTIBILITY ARTIFACTS; BRAIN; ROBUST; EPI; REGISTRATION; DIFFUSION;
D O I
10.3389/fnins.2021.642808
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional magnetic resonance imaging (fMRI) data is typically collected with gradient-echo echo-planar imaging (GE-EPI) sequences, which are particularly prone to the susceptibility artifact as a result of B-0 field inhomogeneity. The component derived from in-plane spin dephasing induces pixel intensity variations and, more critically, geometric distortions. Despite the physical mechanisms underlying the susceptibility artifact being well established, a systematic investigation on the impact of the associated geometric distortions, and the direct comparison of different approaches to tackle them, on fMRI data analyses is missing. Here, we compared two different distortion correction approaches, by acquiring additional: (1) EPI data with reversed phase encoding direction (TOPUP), and (2) standard (and undistorted) GE data at two different echo times (GRE). We first characterized the geometric distortions and the correction approaches based on the estimated Delta B-0 field offset and voxel shift maps, and then conducted three types of analyses on the distorted and corrected fMRI data: (1) registration into structural data, (2) identification of resting-state networks (RSNs), and (3) mapping of task-related brain regions of interest. GRE estimated the largest voxel shifts and more positively impacted the quality of the analyses, in terms of the (significantly lower) cost function of the registration, the (higher) spatial overlap between the RSNs and appropriate templates, and the (significantly higher) sensitivity of the task-related mapping based on the Z-score values of the associated activation maps, although also evident when considering TOPUP. fMRI data should thus be corrected for geometric distortions, with the choice of the approach having a modest, albeit positive, impact on the fMRI analyses.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Simultaneous correction for interscan patient motion and geometric distortions in echoplanar imaging
    Ernst, T
    Speck, O
    Itti, L
    Chang, L
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 201 - 205
  • [22] Simultaneous correction for interscan patient motion and geometric distortions in echoplanar imaging
    Department of Radiology, Harbor UCLA Medical Center, 1124 W. Carson Street, N-11, Torrance, CA 90502, United States
    不详
    Magn. Reson. Med., 1 (201-205):
  • [23] NON RIGID GEOMETRIC DISTORTIONS CORRECTION - APPLICATION TO ATMOSPHERIC TURBULENCE STABILIZATION
    Mao, Yu
    Gilles, Jerome
    INVERSE PROBLEMS AND IMAGING, 2012, 6 (03) : 531 - 546
  • [24] LOCAL CORRECTION OF GEOMETRIC DISTORTIONS IN DIGITAL X-RAY IMAGES
    SANDERSON, AR
    PARKER, DL
    RADIOLOGY, 1995, 197 : 290 - 290
  • [25] Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products
    Habib, Ayman F.
    Kersting, Ana P.
    Shaker, Ahmed
    Yan, Wai-Yeung
    SENSORS, 2011, 11 (09) : 9069 - 9097
  • [26] HJ-1A/B CCD IMAGERY Geometric Distortions and Precise Geometric Correction accuracy analysis
    Hu, Chang-Miao
    Tang, Ping
    2011 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2011, : 4050 - 4053
  • [27] GEOMETRIC DISTORTIONS IN SIDE-SCAN SONAR IMAGES - A PROCEDURE FOR THEIR ESTIMATION AND CORRECTION
    COBRA, DT
    OPPENHEIM, AV
    JAFFE, JS
    IEEE JOURNAL OF OCEANIC ENGINEERING, 1992, 17 (03) : 252 - 268
  • [28] CORRECTION FOR ATTENUATION AND GEOMETRIC POINT RESPONSE DISTORTIONS IN CLINICAL CARDIAC SPECT STUDIES
    GULLBERG, GT
    ZENG, GL
    CHRISTIAN, PE
    DATZ, FL
    MORGAN, HT
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P30 - P30
  • [29] Geometric correction of APEX hyperspectral data
    Vreys, Kristin
    Iordache, Marian-Daniel
    Biesemans, Jan
    Meuleman, Koen
    MISCELLANEA GEOGRAPHICA, 2016, 20 (01): : 11 - 15
  • [30] The Impact of T1 Versus EPI Spatial Normalization Templates for fMRI Data Analyses
    Calhoun, Vince D.
    Wager, Tor D.
    Krishnan, Anjali
    Rosch, Keri S.
    Seymour, Karen E.
    Nebel, Mary Beth
    Mostofsky, Stewart H.
    Nyalakanai, Prashanth
    Kiehl, Kent
    HUMAN BRAIN MAPPING, 2017, 38 (11) : 5331 - 5342