Cross-Calibration of SMART-1 XSM with GOES and RHESSI

被引:5
|
作者
Vaananen, Mikko [1 ]
Alha, Lauri [1 ]
Huovelin, Juhani [1 ]
机构
[1] Univ Helsinki, FIN-00014 Helsinki, Finland
基金
芬兰科学院;
关键词
Flares; Solar corona; Sun; SMART-1; XSM; X-rays; Cross-calibration; RHESSI; GOES; SOLAR MONITOR XSM; EMISSION MEASURES; ATOMIC DATABASE; MISSION; TEMPERATURES; PERFORMANCE; EXPRESSIONS; CHIANTI; LINES;
D O I
10.1007/s11207-009-9461-3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A number of X-ray instruments have been active in observing the solar coronal X-ray radiation this decade. We have compared XSM observations with simultaneous GOES and RHESSI observations. We present flux calibrations for all instruments and compare XSM and GOES total emission measures (TEM) and temperatures (T). The model-independent flux comparison with XSM and GOES data in the 1 -aEuro parts per thousand 8 band shows that the fluxes agree with a ratio of 0.94 +/- 0.09 for the data up to April 2005. The Mewe model-dependent Ts and TEMs differ as XSM observes 1.47 +/- 0.03 times higher Ts than GOES and 1.23 +/- 0.08 times higher TEMs and 0.92 +/- 0.05 times lower fluxes. The comparison with RHESSI data in the 6 -aEuro parts per thousand 8 keV band shows that the average XSM/RHESSI flux ratio is 2.63 +/- 0.23. The discrepancies revealed in this study are similar to discrepancies observed in a number of other spaceborne cross-calibration studies.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [41] Closest Stop: The Moon - Smart-1
    Anon
    European Space Agency (Brochure) ESA BR, 2003, (190):
  • [42] SMART-1: An analysis of flight data
    Di Cara, DM
    Estublier, D
    ACTA ASTRONAUTICA, 2005, 57 (2-8) : 250 - 256
  • [43] CROSS-CALIBRATION BETWEEN AIRBORNE SAR SENSORS
    ZINK, M
    OLIVIER, P
    FREEMAN, A
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1993, 31 (01): : 237 - 245
  • [44] Radiometric cross-calibration of Terra ASTER and MODIS
    Yuan, Karen
    Thome, Kurt
    McCorkel, Joel
    EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [45] CROSS-CALIBRATION OF DXA SCANNERS FOR SPINE MEASUREMENTS
    TOTHILL, P
    OSTEOPOROSIS INTERNATIONAL, 1995, 5 (05) : 410 - 411
  • [46] Jason-1 Global Statistical Evaluation and Performance Assessment: Calibration and Cross-Calibration Results
    Dorandeu, J.
    Ablain, M.
    Faugere, Y.
    Mertz, F.
    Soussi, B.
    Vincent, P.
    MARINE GEODESY, 2004, 27 (3-4) : 345 - 372
  • [47] ISO cross-calibration -: Internal and with other facilities
    García-Lario, P
    PROCEEDINGS OF THE CONFERENCE ON THE CALIBRATION LEGACY OF THE ISO MISSION, 2003, 481 : 169 - 174
  • [48] SMART-1 aims at fruitful end
    不详
    ESA BULLETIN-EUROPEAN SPACE AGENCY, 2006, (127) : 84 - 84
  • [49] SMART-1: Development and lessons learnt
    Swedish Space Corporation, Stockholm, Sweden
    不详
    Int. Astro. Fed. Int. Astro. Congr., 1600, (3391-3402):
  • [50] SMART-1“轻吻”月女神
    士元
    太空探索, 2006, (11) : 24 - 27