Cross-Calibration of SMART-1 XSM with GOES and RHESSI

被引:5
|
作者
Vaananen, Mikko [1 ]
Alha, Lauri [1 ]
Huovelin, Juhani [1 ]
机构
[1] Univ Helsinki, FIN-00014 Helsinki, Finland
基金
芬兰科学院;
关键词
Flares; Solar corona; Sun; SMART-1; XSM; X-rays; Cross-calibration; RHESSI; GOES; SOLAR MONITOR XSM; EMISSION MEASURES; ATOMIC DATABASE; MISSION; TEMPERATURES; PERFORMANCE; EXPRESSIONS; CHIANTI; LINES;
D O I
10.1007/s11207-009-9461-3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A number of X-ray instruments have been active in observing the solar coronal X-ray radiation this decade. We have compared XSM observations with simultaneous GOES and RHESSI observations. We present flux calibrations for all instruments and compare XSM and GOES total emission measures (TEM) and temperatures (T). The model-independent flux comparison with XSM and GOES data in the 1 -aEuro parts per thousand 8 band shows that the fluxes agree with a ratio of 0.94 +/- 0.09 for the data up to April 2005. The Mewe model-dependent Ts and TEMs differ as XSM observes 1.47 +/- 0.03 times higher Ts than GOES and 1.23 +/- 0.08 times higher TEMs and 0.92 +/- 0.05 times lower fluxes. The comparison with RHESSI data in the 6 -aEuro parts per thousand 8 keV band shows that the average XSM/RHESSI flux ratio is 2.63 +/- 0.23. The discrepancies revealed in this study are similar to discrepancies observed in a number of other spaceborne cross-calibration studies.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [21] SMART-1 sharpens sight
    不详
    ASTRONOMY & GEOPHYSICS, 2007, 48 (05) : 9 - 9
  • [22] Online Cross-Calibration of Camera and LIDAR
    Blaga, Bianca-Cerasela-Zelia
    Nedevschi, Sergiu
    2017 13TH IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTER COMMUNICATION AND PROCESSING (ICCP), 2017, : 295 - 301
  • [23] Cross-calibration of cluster mass observables
    Cunha, Carlos
    PHYSICAL REVIEW D, 2009, 79 (06):
  • [24] The SMART-1 lunar impact
    Burchell, M. J.
    Robin-Williams, R.
    Foing, B. H.
    ICARUS, 2010, 207 (01) : 28 - 38
  • [25] HJ-1A THERMAL INFRARED BAND CROSS-CALIBRATION AND VALIDATION
    Li, Jiaguo
    Gu, Xingfa
    Zhu, Li
    Yu, Tao
    Li, Xiaoying
    Zhang, Yuxiang
    Gao, Hailiang
    Gong, Hui
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 2167 - +
  • [26] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    Zuo Wang
    PengFeng Xiao
    XingFa Gu
    XueZhi Feng
    XiaoYing Li
    HaiLiang Gao
    Hui Li
    JinTang Lin
    XueLiang Zhang
    Science China Technological Sciences, 2013, 56 : 713 - 723
  • [27] Cross-calibration of two small footprint sensors
    GustafsonBold, CL
    Thome, KJ
    IGARSS '96 - 1996 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM: REMOTE SENSING FOR A SUSTAINABLE FUTURE, VOLS I - IV, 1996, : 1283 - 1285
  • [28] Universal cross-calibration of bone mineral density
    Hui, SL
    Lu, Y
    Genant, HK
    Glueer, CC
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : S602 - S602
  • [29] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    WANG Zuo
    XIAO PengFeng
    GU XingFa
    FENG XueZhi
    LI XiaoYing
    GAO HaiLiang
    LI Hui
    LIN JinTang
    ZHANG XueLiang
    Science China Technological Sciences, 2013, (03) : 713 - 723
  • [30] Uncertainty analysis in cross-calibration and optimization calculation of calibration coefficients
    Gao Shuai
    Li Yuan
    Bai Ting-zhu
    Zhang Yu-xiang
    Zheng Xiao-bing
    CHINESE OPTICS, 2020, 13 (03): : 568 - 576