Cross-Calibration of SMART-1 XSM with GOES and RHESSI

被引:5
|
作者
Vaananen, Mikko [1 ]
Alha, Lauri [1 ]
Huovelin, Juhani [1 ]
机构
[1] Univ Helsinki, FIN-00014 Helsinki, Finland
基金
芬兰科学院;
关键词
Flares; Solar corona; Sun; SMART-1; XSM; X-rays; Cross-calibration; RHESSI; GOES; SOLAR MONITOR XSM; EMISSION MEASURES; ATOMIC DATABASE; MISSION; TEMPERATURES; PERFORMANCE; EXPRESSIONS; CHIANTI; LINES;
D O I
10.1007/s11207-009-9461-3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A number of X-ray instruments have been active in observing the solar coronal X-ray radiation this decade. We have compared XSM observations with simultaneous GOES and RHESSI observations. We present flux calibrations for all instruments and compare XSM and GOES total emission measures (TEM) and temperatures (T). The model-independent flux comparison with XSM and GOES data in the 1 -aEuro parts per thousand 8 band shows that the fluxes agree with a ratio of 0.94 +/- 0.09 for the data up to April 2005. The Mewe model-dependent Ts and TEMs differ as XSM observes 1.47 +/- 0.03 times higher Ts than GOES and 1.23 +/- 0.08 times higher TEMs and 0.92 +/- 0.05 times lower fluxes. The comparison with RHESSI data in the 6 -aEuro parts per thousand 8 keV band shows that the average XSM/RHESSI flux ratio is 2.63 +/- 0.23. The discrepancies revealed in this study are similar to discrepancies observed in a number of other spaceborne cross-calibration studies.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 50 条
  • [1] Cross-Calibration of SMART-1 XSM with GOES and RHESSI
    Mikko Väänänen
    Lauri Alha
    Juhani Huovelin
    Solar Physics, 2009, 260 : 479 - 488
  • [2] SMART-1 goes out with a bang
    不详
    ASTRONOMY & GEOPHYSICS, 2006, 47 (05) : 4 - 4
  • [3] CROSS-CALIBRATION TECHNIQUES
    HOLLAND, JZ
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 1971, 52 (11) : 1159 - &
  • [4] The in-flight performance of the X-ray Solar Monitor (XSM) on-board SMART-1
    Alha, L.
    Huovelin, J.
    Hackman, T.
    Andersson, H.
    Howe, C. J.
    Esko, Eero
    Vaeaenaenen, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 596 (03): : 317 - 326
  • [5] The SMART-1 mission
    Racca, GD
    Whitcomb, GP
    Foing, BH
    ESA BULLETIN-EUROPEAN SPACE AGENCY, 1998, (95) : 72 - 81
  • [6] A Satellite Cross-Calibration Experiment
    Nieke, Jens
    Aoki, Teruo
    Tanikawa, Tomonori
    Motoyoshi, Hiroki
    Hori, Masahiro
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2004, 1 (03) : 215 - 219
  • [7] CROSS-CALIBRATION OF UPTAKE SYSTEMS
    HIDALGO, JU
    JOURNAL OF NUCLEAR MEDICINE, 1960, 1 (01) : 60 - 60
  • [8] Impact of a Hyperspectral Satellite Cross-Calibration Radiometer's Spatial and Noise Characteristics on Cross-Calibration
    Ryan, Robert E.
    Pagnutti, Mary
    Huggins, Max
    Burch, Kara
    Sitton, David
    Manriquez, Kimberly
    Ryan, Hannah
    REMOTE SENSING, 2023, 15 (18)
  • [9] Cross-calibration of probabilistic forecasts
    Strahl, Christof
    Ziegel, Johanna
    ELECTRONIC JOURNAL OF STATISTICS, 2017, 11 (01): : 608 - 639
  • [10] Cross-calibration of PRONAOS & ISO
    Stepnik, B
    Pajot, F
    Lamarre, JM
    Abergel, A
    Bernard, JP
    Giard, M
    Meny, C
    Ristorcelli, I
    Serra, G
    Torre, JP
    PROCEEDINGS OF THE CONFERENCE ON THE CALIBRATION LEGACY OF THE ISO MISSION, 2003, 481 : 187 - 190